三种旋转文件系统对单根牙粪肠球菌的体外研究

IF 2 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Roghith Kannan, Bassem Eid, Pooja Adtani, Tarek Elsewify, Ranya Elemam
{"title":"三种旋转文件系统对单根牙粪肠球菌的体外研究","authors":"Roghith Kannan, Bassem Eid, Pooja Adtani, Tarek Elsewify, Ranya Elemam","doi":"10.14744/eej.2025.51423","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the effectiveness of three rotary file systems on the elimination of Enterococcus faecalis (E. faecalis) biofilms in single-rooted teeth.</p><p><strong>Methods: </strong>A total of 70 mandibular premolars were included in this study in which 60 root canals were inoculated with E. faecalis. The positive control group (n=5) received bacterial inoculation without mechanical preparation. The negative control group (n=5) was neither infected nor mechanically prepared. The teeth were randomly assigned to 3 experimental groups (n=20 per-group) according to application of the rotary files: Group 1: XP-endo Rise Shaper (FKG, Le Crêt-du-Locle, Switzerland); Group 2: XP-endo Shaper (FKG, Le Crêt-du-Locle, Switzerland); Group 3: ProTaper Gold (Dentsply Sirona, Erlangen, Germany). Samples were collected using paper points before (S1) and after (S2) mechanical preparation. Colony-forming units (CFUs) were used to quantify bacterial loads.</p><p><strong>Results: </strong>Significant differences in bacterial counts were observed from S1 to S2 in all tested groups (p<0.001). Intergroup comparisons revealed no significant differences between the XP-endo Rise Shaper and XP-endo Shaper groups (p>0.05) and between XP-endo Shaper and ProTaper Gold groups (p>0.05). Significant differences were observed between the XP-endo Rise Shaper and ProTaper Gold groups (p<0.05). The XP-endo Rise shaper group showed the largest reduction in bacterial loads (98.2%), followed by the XP-endo Shaper (96.0%) and ProTaper Gold (93.8%) groups.</p><p><strong>Conclusion: </strong>All tested rotary files were able to reduce bacteria but the novel single-file system (XP-endo Rise shaper) was superior in reducing bacterial load compared to XP-endo Shaper and the multiple file system (ProTaper Gold). (EEJ-2024-08-133).</p>","PeriodicalId":11860,"journal":{"name":"European Endodontic Journal","volume":"10 3","pages":"230-236"},"PeriodicalIF":2.0000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12102771/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effectiveness of Three Rotary File Systems on Enterococcus Faecalis in Single Rooted Teeth: An In Vitro Study.\",\"authors\":\"Roghith Kannan, Bassem Eid, Pooja Adtani, Tarek Elsewify, Ranya Elemam\",\"doi\":\"10.14744/eej.2025.51423\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To evaluate the effectiveness of three rotary file systems on the elimination of Enterococcus faecalis (E. faecalis) biofilms in single-rooted teeth.</p><p><strong>Methods: </strong>A total of 70 mandibular premolars were included in this study in which 60 root canals were inoculated with E. faecalis. The positive control group (n=5) received bacterial inoculation without mechanical preparation. The negative control group (n=5) was neither infected nor mechanically prepared. The teeth were randomly assigned to 3 experimental groups (n=20 per-group) according to application of the rotary files: Group 1: XP-endo Rise Shaper (FKG, Le Crêt-du-Locle, Switzerland); Group 2: XP-endo Shaper (FKG, Le Crêt-du-Locle, Switzerland); Group 3: ProTaper Gold (Dentsply Sirona, Erlangen, Germany). Samples were collected using paper points before (S1) and after (S2) mechanical preparation. Colony-forming units (CFUs) were used to quantify bacterial loads.</p><p><strong>Results: </strong>Significant differences in bacterial counts were observed from S1 to S2 in all tested groups (p<0.001). Intergroup comparisons revealed no significant differences between the XP-endo Rise Shaper and XP-endo Shaper groups (p>0.05) and between XP-endo Shaper and ProTaper Gold groups (p>0.05). Significant differences were observed between the XP-endo Rise Shaper and ProTaper Gold groups (p<0.05). The XP-endo Rise shaper group showed the largest reduction in bacterial loads (98.2%), followed by the XP-endo Shaper (96.0%) and ProTaper Gold (93.8%) groups.</p><p><strong>Conclusion: </strong>All tested rotary files were able to reduce bacteria but the novel single-file system (XP-endo Rise shaper) was superior in reducing bacterial load compared to XP-endo Shaper and the multiple file system (ProTaper Gold). (EEJ-2024-08-133).</p>\",\"PeriodicalId\":11860,\"journal\":{\"name\":\"European Endodontic Journal\",\"volume\":\"10 3\",\"pages\":\"230-236\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2025-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12102771/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Endodontic Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14744/eej.2025.51423\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Endodontic Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14744/eej.2025.51423","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价三种旋转锉系统去除单根牙内粪肠球菌生物膜的效果。方法:选取70颗下颌前磨牙,其中60颗根管接种粪肠杆菌。阳性对照组(n=5)接种细菌,不进行机械制备。阴性对照组(n=5)未感染,未机械制备。根据旋转锉的应用情况,将牙随机分为3个实验组(每组20颗):第一组:XP-endo Rise Shaper (FKG, Le Crêt-du-Locle,瑞士);第二组:XP-endo塑形器(FKG, Le Crêt-du-Locle,瑞士);第三组:ProTaper Gold (Dentsply Sirona, Erlangen, Germany)。在机械制备前(S1)和后(S2)用纸点采集样品。菌落形成单位(cfu)用于量化细菌负荷。结果:各试验组S1 ~ S2间细菌数量差异有统计学意义(p < 0.05), XP-endo Shaper组与ProTaper Gold组间细菌数量差异有统计学意义(p < 0.05)。结论:所有旋转锉均能减少细菌,但新型单锉系统(XP-endo Rise Shaper)在减少细菌负荷方面优于XP-endo Shaper和多锉系统(ProTaper Gold)。(eej - 2024 - 08 - 133)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effectiveness of Three Rotary File Systems on Enterococcus Faecalis in Single Rooted Teeth: An In Vitro Study.

Objective: To evaluate the effectiveness of three rotary file systems on the elimination of Enterococcus faecalis (E. faecalis) biofilms in single-rooted teeth.

Methods: A total of 70 mandibular premolars were included in this study in which 60 root canals were inoculated with E. faecalis. The positive control group (n=5) received bacterial inoculation without mechanical preparation. The negative control group (n=5) was neither infected nor mechanically prepared. The teeth were randomly assigned to 3 experimental groups (n=20 per-group) according to application of the rotary files: Group 1: XP-endo Rise Shaper (FKG, Le Crêt-du-Locle, Switzerland); Group 2: XP-endo Shaper (FKG, Le Crêt-du-Locle, Switzerland); Group 3: ProTaper Gold (Dentsply Sirona, Erlangen, Germany). Samples were collected using paper points before (S1) and after (S2) mechanical preparation. Colony-forming units (CFUs) were used to quantify bacterial loads.

Results: Significant differences in bacterial counts were observed from S1 to S2 in all tested groups (p<0.001). Intergroup comparisons revealed no significant differences between the XP-endo Rise Shaper and XP-endo Shaper groups (p>0.05) and between XP-endo Shaper and ProTaper Gold groups (p>0.05). Significant differences were observed between the XP-endo Rise Shaper and ProTaper Gold groups (p<0.05). The XP-endo Rise shaper group showed the largest reduction in bacterial loads (98.2%), followed by the XP-endo Shaper (96.0%) and ProTaper Gold (93.8%) groups.

Conclusion: All tested rotary files were able to reduce bacteria but the novel single-file system (XP-endo Rise shaper) was superior in reducing bacterial load compared to XP-endo Shaper and the multiple file system (ProTaper Gold). (EEJ-2024-08-133).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Endodontic Journal
European Endodontic Journal DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.40
自引率
5.60%
发文量
25
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信