不同贴面工艺对氧化锆框架贴面陶瓷冠力学性能及半透明性的影响。

Q3 Dentistry
Abdelrahman Gamal Sanad, Cherif Adel Mohsen, Mostafa Elhosseiny Mohamed
{"title":"不同贴面工艺对氧化锆框架贴面陶瓷冠力学性能及半透明性的影响。","authors":"Abdelrahman Gamal Sanad, Cherif Adel Mohsen, Mostafa Elhosseiny Mohamed","doi":"10.5005/jp-journals-10024-3837","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>The aim of this study is to assess the effect of veneering techniques on bond strength, fracture resistance (FR), and translucency of zirconia framework-veneer ceramic crowns.</p><p><strong>Materials and methods: </strong>Four commercially available glass ceramic materials were used in this study: IPS e.max CAD (Ivoclar Vivadent), IPS e.max Zirpress (Ivoclar Vivadent), IPS e.max Ceram powder (Ivoclar Vivadent), and IPS e.max Zir CAD Prime (Ivoclar Vivadent). The first three materials were used to fabricate veneering layer over the fourth material (zirconia frameworks) to create samples in the forms of crowns (core veneered with superstructure) to study the FR (<i>n</i> = 30) and plates veneered with ceramic discs to study shear bond strength (SBS) and translucency parameter (TP) (<i>n</i> = 60). A total of 90 samples were constructed. The samples were divided into three equal groups: Group A: CAD-ON Technique (<i>n</i> = 30); group B: Press-over technique (<i>n</i> = 30); and group C: Ttraditional layering technique (<i>n</i> = 30). Each group is divided into three subgroups according to the type of test. Subgroup (1): Shear bond strength (<i>n</i> = 10). Subgroup (2): Fracture resistance and subgroup (3) translucency (<i>n</i> = 10). A universal testing machine (5ST; Tinius Olsen, England) was used to measure FR and SBS. A spectrophotometer was used to measure color parameters (L*, a*, b*) and total luminous transmittance (τ) of the specimens for calculation of TP. One-way analysis of variance (ANOVA) test combined with a <i>post hoc</i> test was used to analyze the data (α = 0.05).</p><p><strong>Results: </strong>The mean FR was high for the CAD-ON technique (<i>N</i> ± SD) (1723.80 ± 110.96) followed by the layering technique (1092.70 ± 181.35), and lowest for the press-over technique (820.80 ± 75.95). The difference between the groups was statistically significant (<i>p</i>-value < 0.05). The mean SBS values were also highest for the CAD-ON technique (MPa ± SD) (28.00 ± 1.96), followed by the layering technique (25.71 ± 0.79), and lowest for the press-over technique (20.80 ± 1.46). For TP, the press-over technique had the highest mean value (6.05 ± 0.32), followed by the layering technique (5.56 ± 0.27), and then CAD-ON technique (5.15 ± 0.33). A statistically significant difference was observed among the three techniques (<i>p</i> < 0.05).</p><p><strong>Conclusion: </strong>The file-splitting (CAD-ON) veneering technique shows higher FR and bonding strength. In contrast, veneering zirconia using the layering and press-over techniques resulted in samples with higher translucency compared to those veneered with the CAD-ON technique.</p><p><strong>Clinical significance: </strong>The clinical significance lies in the potential to enhance the longevity, esthetics, and overall performance of dental restorations. By understanding how various veneering techniques impact these factors, dental professionals can improve durability, enhance esthetic outcomes, and guide treatment planning. How to cite this article: Sanad AG, Mohsen CA, Mohamed ME. Effect of Different Veneering Techniques on Mechanical Properties and Translucency of Zirconia Framework-veneer Ceramic Crowns. J Contemp Dent Pract 2025;26(3):294-302.</p>","PeriodicalId":35792,"journal":{"name":"Journal of Contemporary Dental Practice","volume":"26 3","pages":"294-302"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Different Veneering Techniques on Mechanical Properties and Translucency of Zirconia Framework-veneer Ceramic Crowns.\",\"authors\":\"Abdelrahman Gamal Sanad, Cherif Adel Mohsen, Mostafa Elhosseiny Mohamed\",\"doi\":\"10.5005/jp-journals-10024-3837\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>The aim of this study is to assess the effect of veneering techniques on bond strength, fracture resistance (FR), and translucency of zirconia framework-veneer ceramic crowns.</p><p><strong>Materials and methods: </strong>Four commercially available glass ceramic materials were used in this study: IPS e.max CAD (Ivoclar Vivadent), IPS e.max Zirpress (Ivoclar Vivadent), IPS e.max Ceram powder (Ivoclar Vivadent), and IPS e.max Zir CAD Prime (Ivoclar Vivadent). The first three materials were used to fabricate veneering layer over the fourth material (zirconia frameworks) to create samples in the forms of crowns (core veneered with superstructure) to study the FR (<i>n</i> = 30) and plates veneered with ceramic discs to study shear bond strength (SBS) and translucency parameter (TP) (<i>n</i> = 60). A total of 90 samples were constructed. The samples were divided into three equal groups: Group A: CAD-ON Technique (<i>n</i> = 30); group B: Press-over technique (<i>n</i> = 30); and group C: Ttraditional layering technique (<i>n</i> = 30). Each group is divided into three subgroups according to the type of test. Subgroup (1): Shear bond strength (<i>n</i> = 10). Subgroup (2): Fracture resistance and subgroup (3) translucency (<i>n</i> = 10). A universal testing machine (5ST; Tinius Olsen, England) was used to measure FR and SBS. A spectrophotometer was used to measure color parameters (L*, a*, b*) and total luminous transmittance (τ) of the specimens for calculation of TP. One-way analysis of variance (ANOVA) test combined with a <i>post hoc</i> test was used to analyze the data (α = 0.05).</p><p><strong>Results: </strong>The mean FR was high for the CAD-ON technique (<i>N</i> ± SD) (1723.80 ± 110.96) followed by the layering technique (1092.70 ± 181.35), and lowest for the press-over technique (820.80 ± 75.95). The difference between the groups was statistically significant (<i>p</i>-value < 0.05). The mean SBS values were also highest for the CAD-ON technique (MPa ± SD) (28.00 ± 1.96), followed by the layering technique (25.71 ± 0.79), and lowest for the press-over technique (20.80 ± 1.46). For TP, the press-over technique had the highest mean value (6.05 ± 0.32), followed by the layering technique (5.56 ± 0.27), and then CAD-ON technique (5.15 ± 0.33). A statistically significant difference was observed among the three techniques (<i>p</i> < 0.05).</p><p><strong>Conclusion: </strong>The file-splitting (CAD-ON) veneering technique shows higher FR and bonding strength. In contrast, veneering zirconia using the layering and press-over techniques resulted in samples with higher translucency compared to those veneered with the CAD-ON technique.</p><p><strong>Clinical significance: </strong>The clinical significance lies in the potential to enhance the longevity, esthetics, and overall performance of dental restorations. By understanding how various veneering techniques impact these factors, dental professionals can improve durability, enhance esthetic outcomes, and guide treatment planning. How to cite this article: Sanad AG, Mohsen CA, Mohamed ME. Effect of Different Veneering Techniques on Mechanical Properties and Translucency of Zirconia Framework-veneer Ceramic Crowns. J Contemp Dent Pract 2025;26(3):294-302.</p>\",\"PeriodicalId\":35792,\"journal\":{\"name\":\"Journal of Contemporary Dental Practice\",\"volume\":\"26 3\",\"pages\":\"294-302\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Contemporary Dental Practice\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5005/jp-journals-10024-3837\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Contemporary Dental Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5005/jp-journals-10024-3837","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究的目的是评估贴面技术对氧化锆框架贴面陶瓷冠的结合强度、抗断裂能力和透明度的影响。材料和方法:本研究采用4种市售玻璃陶瓷材料:IPS e.max CAD (Ivoclar Vivadent)、IPS e.max Zirpress (Ivoclar Vivadent)、IPS e.max陶瓷粉(Ivoclar Vivadent)和IPS e.max Zir CAD Prime (Ivoclar Vivadent)。使用前三种材料在第四种材料(氧化锆框架)上制作贴面层,以冠(核心贴面,上层结构)的形式制作样品,以研究FR (n = 30)和陶瓷盘贴面的板,以研究剪切结合强度(SBS)和半透明参数(TP) (n = 60)。共构建90个样本。样本分为三组:A组:CAD-ON技术(n = 30);B组:侧压法(n = 30);C组:传统分层法(n = 30)。每组根据测试类型分为三个子组。亚组(1):剪切粘结强度(n = 10)。亚组(2):抗断裂;亚组(3):透光性(n = 10)。万能试验机(5ST;使用Tinius Olsen, England)测量FR和SBS。用分光光度计测定样品的颜色参数(L*、A *、b*)和总透光率(τ),计算TP。采用单因素方差分析(ANOVA)联合事后检验对数据进行分析(α = 0.05)。结果:CAD-ON技术的平均FR最高(N±SD)(1723.80±110.96),其次是分层技术(1092.70±181.35),压覆技术最低(820.80±75.95)。两组间差异有统计学意义(p值< 0.05)。cad - - - - -技术的平均SBS值最高(MPa±SD)(28.00±1.96),分层技术次之(25.71±0.79),压覆技术最低(20.80±1.46)。TP的平均值以压过法最高(6.05±0.32),分层法次之(5.56±0.27),CAD-ON法次之(5.15±0.33)。三种方法间比较,差异有统计学意义(p < 0.05)。结论:CAD-ON贴面技术具有较高的FR和粘接强度。相比之下,与使用CAD-ON技术贴面的样品相比,使用分层和压覆技术贴面的氧化锆样品具有更高的半透明性。临床意义:临床意义在于提高牙体修复体的寿命、美观性和整体性能。通过了解各种贴面技术如何影响这些因素,牙科专业人员可以提高耐用性,提高美观效果,并指导治疗计划。如何引用本文:Sanad AG, Mohsen CA, Mohamed ME。不同贴面工艺对氧化锆框架贴面陶瓷冠力学性能及半透明性的影响。[J] .现代医学学报;2015;26(3):294-302。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of Different Veneering Techniques on Mechanical Properties and Translucency of Zirconia Framework-veneer Ceramic Crowns.

Aim: The aim of this study is to assess the effect of veneering techniques on bond strength, fracture resistance (FR), and translucency of zirconia framework-veneer ceramic crowns.

Materials and methods: Four commercially available glass ceramic materials were used in this study: IPS e.max CAD (Ivoclar Vivadent), IPS e.max Zirpress (Ivoclar Vivadent), IPS e.max Ceram powder (Ivoclar Vivadent), and IPS e.max Zir CAD Prime (Ivoclar Vivadent). The first three materials were used to fabricate veneering layer over the fourth material (zirconia frameworks) to create samples in the forms of crowns (core veneered with superstructure) to study the FR (n = 30) and plates veneered with ceramic discs to study shear bond strength (SBS) and translucency parameter (TP) (n = 60). A total of 90 samples were constructed. The samples were divided into three equal groups: Group A: CAD-ON Technique (n = 30); group B: Press-over technique (n = 30); and group C: Ttraditional layering technique (n = 30). Each group is divided into three subgroups according to the type of test. Subgroup (1): Shear bond strength (n = 10). Subgroup (2): Fracture resistance and subgroup (3) translucency (n = 10). A universal testing machine (5ST; Tinius Olsen, England) was used to measure FR and SBS. A spectrophotometer was used to measure color parameters (L*, a*, b*) and total luminous transmittance (τ) of the specimens for calculation of TP. One-way analysis of variance (ANOVA) test combined with a post hoc test was used to analyze the data (α = 0.05).

Results: The mean FR was high for the CAD-ON technique (N ± SD) (1723.80 ± 110.96) followed by the layering technique (1092.70 ± 181.35), and lowest for the press-over technique (820.80 ± 75.95). The difference between the groups was statistically significant (p-value < 0.05). The mean SBS values were also highest for the CAD-ON technique (MPa ± SD) (28.00 ± 1.96), followed by the layering technique (25.71 ± 0.79), and lowest for the press-over technique (20.80 ± 1.46). For TP, the press-over technique had the highest mean value (6.05 ± 0.32), followed by the layering technique (5.56 ± 0.27), and then CAD-ON technique (5.15 ± 0.33). A statistically significant difference was observed among the three techniques (p < 0.05).

Conclusion: The file-splitting (CAD-ON) veneering technique shows higher FR and bonding strength. In contrast, veneering zirconia using the layering and press-over techniques resulted in samples with higher translucency compared to those veneered with the CAD-ON technique.

Clinical significance: The clinical significance lies in the potential to enhance the longevity, esthetics, and overall performance of dental restorations. By understanding how various veneering techniques impact these factors, dental professionals can improve durability, enhance esthetic outcomes, and guide treatment planning. How to cite this article: Sanad AG, Mohsen CA, Mohamed ME. Effect of Different Veneering Techniques on Mechanical Properties and Translucency of Zirconia Framework-veneer Ceramic Crowns. J Contemp Dent Pract 2025;26(3):294-302.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Contemporary Dental Practice
Journal of Contemporary Dental Practice Dentistry-Dentistry (all)
CiteScore
1.80
自引率
0.00%
发文量
174
期刊介绍: The Journal of Contemporary Dental Practice (JCDP), is a peer-reviewed, open access MEDLINE indexed journal. The journal’s full text is available online at http://www.thejcdp.com. The journal allows free access (open access) to its contents. Articles with clinical relevance will be given preference for publication. The Journal publishes original research papers, review articles, rare and novel case reports, and clinical techniques. Manuscripts are invited from all specialties of dentistry i.e., conservative dentistry and endodontics, dentofacial orthopedics and orthodontics, oral medicine and radiology, oral pathology, oral surgery, orodental diseases, pediatric dentistry, implantology, periodontics, clinical aspects of public health dentistry, and prosthodontics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信