弱电网条件下vdc - hvdc系统的同步电压重构

IF 6.1 1区 工程技术 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC
Weiye Diao;Ao Liu;Jun Mei;Linyuan Wang;Guanghua Wang;Fujin Deng
{"title":"弱电网条件下vdc - hvdc系统的同步电压重构","authors":"Weiye Diao;Ao Liu;Jun Mei;Linyuan Wang;Guanghua Wang;Fujin Deng","doi":"10.35833/MPCE.2024.000650","DOIUrl":null,"url":null,"abstract":"Under weak grid conditions, grid impedance is coupled with a control system for voltage source converter based high-voltage direct current (VSC-HVDC) systems, resulting in decreased synchronization stability. Unfortunately, most studies are based on the assumption that impedance ratio <tex>$(R/X)$</tex> is sufficiently small to ignore the effects of grid impedance. In this study, we establish a dynamic coupling model that includes grid impedance and control loops, revealing the influence mechanism of <tex>$R/X$</tex> on synchronization stability from a physical perspective. We also quantify the stability range of <tex>$R/X$</tex> in the static analysis model and introduce a sensitivity factor to measure its effect on voltage stability. Additionally, we utilize a dynamic analysis model to evaluate power angle convergence, proposing a corresponding stability criterion. We then present a method of synchronous voltage reconstruction aimed at enhancing the grid strength. Theoretical analysis shows that this method can effectively mitigate the effects of coupling between grid impedance and the controller under weak grid conditions, ensuring stable operation even under extremely weak grid conditions. Experiments validate the accuracy and effectiveness of the analysis and method.","PeriodicalId":51326,"journal":{"name":"Journal of Modern Power Systems and Clean Energy","volume":"13 3","pages":"1040-1051"},"PeriodicalIF":6.1000,"publicationDate":"2025-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10981584","citationCount":"0","resultStr":"{\"title\":\"Synchronous Voltage Reconstruction of VSC-HVDC Systems Under Weak Grid Conditions\",\"authors\":\"Weiye Diao;Ao Liu;Jun Mei;Linyuan Wang;Guanghua Wang;Fujin Deng\",\"doi\":\"10.35833/MPCE.2024.000650\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Under weak grid conditions, grid impedance is coupled with a control system for voltage source converter based high-voltage direct current (VSC-HVDC) systems, resulting in decreased synchronization stability. Unfortunately, most studies are based on the assumption that impedance ratio <tex>$(R/X)$</tex> is sufficiently small to ignore the effects of grid impedance. In this study, we establish a dynamic coupling model that includes grid impedance and control loops, revealing the influence mechanism of <tex>$R/X$</tex> on synchronization stability from a physical perspective. We also quantify the stability range of <tex>$R/X$</tex> in the static analysis model and introduce a sensitivity factor to measure its effect on voltage stability. Additionally, we utilize a dynamic analysis model to evaluate power angle convergence, proposing a corresponding stability criterion. We then present a method of synchronous voltage reconstruction aimed at enhancing the grid strength. Theoretical analysis shows that this method can effectively mitigate the effects of coupling between grid impedance and the controller under weak grid conditions, ensuring stable operation even under extremely weak grid conditions. Experiments validate the accuracy and effectiveness of the analysis and method.\",\"PeriodicalId\":51326,\"journal\":{\"name\":\"Journal of Modern Power Systems and Clean Energy\",\"volume\":\"13 3\",\"pages\":\"1040-1051\"},\"PeriodicalIF\":6.1000,\"publicationDate\":\"2025-04-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10981584\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Modern Power Systems and Clean Energy\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10981584/\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Modern Power Systems and Clean Energy","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10981584/","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

在弱电网条件下,电网阻抗与基于电压源变换器的高压直流(vcs - hvdc)系统的控制系统耦合,导致同步稳定性下降。不幸的是,大多数研究都是基于阻抗比$(R/X)$足够小而忽略网格阻抗的影响的假设。在本研究中,我们建立了包含电网阻抗和控制回路的动态耦合模型,从物理角度揭示了$R/X$对同步稳定性的影响机制。我们还量化了静态分析模型中$R/X$的稳定范围,并引入了一个灵敏度因子来测量其对电压稳定性的影响。此外,我们利用动态分析模型来评估功率角收敛性,并提出相应的稳定性判据。然后,我们提出了一种旨在提高电网强度的同步电压重建方法。理论分析表明,该方法可以有效缓解弱电网条件下电网阻抗与控制器耦合的影响,即使在极弱的电网条件下也能保证稳定运行。实验验证了分析方法的准确性和有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Synchronous Voltage Reconstruction of VSC-HVDC Systems Under Weak Grid Conditions
Under weak grid conditions, grid impedance is coupled with a control system for voltage source converter based high-voltage direct current (VSC-HVDC) systems, resulting in decreased synchronization stability. Unfortunately, most studies are based on the assumption that impedance ratio $(R/X)$ is sufficiently small to ignore the effects of grid impedance. In this study, we establish a dynamic coupling model that includes grid impedance and control loops, revealing the influence mechanism of $R/X$ on synchronization stability from a physical perspective. We also quantify the stability range of $R/X$ in the static analysis model and introduce a sensitivity factor to measure its effect on voltage stability. Additionally, we utilize a dynamic analysis model to evaluate power angle convergence, proposing a corresponding stability criterion. We then present a method of synchronous voltage reconstruction aimed at enhancing the grid strength. Theoretical analysis shows that this method can effectively mitigate the effects of coupling between grid impedance and the controller under weak grid conditions, ensuring stable operation even under extremely weak grid conditions. Experiments validate the accuracy and effectiveness of the analysis and method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Modern Power Systems and Clean Energy
Journal of Modern Power Systems and Clean Energy ENGINEERING, ELECTRICAL & ELECTRONIC-
CiteScore
12.30
自引率
14.30%
发文量
97
审稿时长
13 weeks
期刊介绍: Journal of Modern Power Systems and Clean Energy (MPCE), commencing from June, 2013, is a newly established, peer-reviewed and quarterly published journal in English. It is the first international power engineering journal originated in mainland China. MPCE publishes original papers, short letters and review articles in the field of modern power systems with focus on smart grid technology and renewable energy integration, etc.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信