股骨近端骨折顺行髓内钉内固定发生股骨远端骨折的风险:有限元研究。

IF 2.1 3区 医学 Q2 ORTHOPEDICS
Gregory R Roytman, Sophia Lahik, Steven M Tommasini, Daniel H Wiznia, Brianna R Fram
{"title":"股骨近端骨折顺行髓内钉内固定发生股骨远端骨折的风险:有限元研究。","authors":"Gregory R Roytman, Sophia Lahik, Steven M Tommasini, Daniel H Wiznia, Brianna R Fram","doi":"10.1002/jor.26113","DOIUrl":null,"url":null,"abstract":"<p><p>Surgeons often use long antegrade intramedullary nails (aIMNs) when fixing fractures of the proximal femur in geriatric patients. However, risk of peri-implant fracture in relation to aIMN termination level has not yet been studied. We therefore studied the correlation between aIMN nail tip termination level and extent of distal femur fracture in three different loading scenarios using finite element models of seven different length aIMNs. These were loaded into 3D models of synthetic osteoporotic femurs, which were loaded in single-leg stance (SLS) with body weight load at the femoral head, torsion (TOR) counterclockwise to failure with 120 Nm of torque, and distal impact/fall (DIF) simulating direct fall on the knees at 1000 mm/sec. The maximum stress in SLS and percentage of failed elements for TOR and DIF were recorded. For SLS, aIMN tip termination and maximum stress were not correlated (ρ = 0.1429, p = 0.7599) and there was no apparent trend in the data. For TOR, more proximal aIMN tip termination demonstrated a significant correlation with greater percentage of failed area (ρ = 0.9286, p = 0.0025). For DIF, aIMN tip termination was not correlated with the percentage of failed elements (ρ = -0.6071, p = 0.1482), but demonstrated a statistically significant Gaussian relationship (coeffs: <math> <semantics> <mrow><mrow><mi>a</mi></mrow> </mrow> <annotation>$a$</annotation></semantics> </math>  = 2.22 (p = 1.13 × 10<sup>-3</sup>), <math> <semantics> <mrow><mrow><mi>b</mi></mrow> </mrow> <annotation>$b$</annotation></semantics> </math>  = 58.61 (p = 1.89 × 10<sup>-5</sup>), <math> <semantics> <mrow><mrow><mi>c</mi></mrow> </mrow> <annotation>$c$</annotation></semantics> </math>  = 17.46 (p = 1.79 × 10<sup>-3</sup>)) where 60 mm aIMN tip termination demonstrated the greatest percentage of failed area. Therefore, we found a strong linear relationship between more proximal aIMN termination in the femur and extent of failure in TOR. There was a statistically significant Gaussian relationship between metaphyseal termination and extent of failure in DIF.</p>","PeriodicalId":16650,"journal":{"name":"Journal of Orthopaedic Research®","volume":" ","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2025-05-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Risk of Distal Femur Fracture in Antegrade Intramedullary Nail Fixation of Proximal Femur Fractures: A Finite Element Study.\",\"authors\":\"Gregory R Roytman, Sophia Lahik, Steven M Tommasini, Daniel H Wiznia, Brianna R Fram\",\"doi\":\"10.1002/jor.26113\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Surgeons often use long antegrade intramedullary nails (aIMNs) when fixing fractures of the proximal femur in geriatric patients. However, risk of peri-implant fracture in relation to aIMN termination level has not yet been studied. We therefore studied the correlation between aIMN nail tip termination level and extent of distal femur fracture in three different loading scenarios using finite element models of seven different length aIMNs. These were loaded into 3D models of synthetic osteoporotic femurs, which were loaded in single-leg stance (SLS) with body weight load at the femoral head, torsion (TOR) counterclockwise to failure with 120 Nm of torque, and distal impact/fall (DIF) simulating direct fall on the knees at 1000 mm/sec. The maximum stress in SLS and percentage of failed elements for TOR and DIF were recorded. For SLS, aIMN tip termination and maximum stress were not correlated (ρ = 0.1429, p = 0.7599) and there was no apparent trend in the data. For TOR, more proximal aIMN tip termination demonstrated a significant correlation with greater percentage of failed area (ρ = 0.9286, p = 0.0025). For DIF, aIMN tip termination was not correlated with the percentage of failed elements (ρ = -0.6071, p = 0.1482), but demonstrated a statistically significant Gaussian relationship (coeffs: <math> <semantics> <mrow><mrow><mi>a</mi></mrow> </mrow> <annotation>$a$</annotation></semantics> </math>  = 2.22 (p = 1.13 × 10<sup>-3</sup>), <math> <semantics> <mrow><mrow><mi>b</mi></mrow> </mrow> <annotation>$b$</annotation></semantics> </math>  = 58.61 (p = 1.89 × 10<sup>-5</sup>), <math> <semantics> <mrow><mrow><mi>c</mi></mrow> </mrow> <annotation>$c$</annotation></semantics> </math>  = 17.46 (p = 1.79 × 10<sup>-3</sup>)) where 60 mm aIMN tip termination demonstrated the greatest percentage of failed area. Therefore, we found a strong linear relationship between more proximal aIMN termination in the femur and extent of failure in TOR. There was a statistically significant Gaussian relationship between metaphyseal termination and extent of failure in DIF.</p>\",\"PeriodicalId\":16650,\"journal\":{\"name\":\"Journal of Orthopaedic Research®\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2025-05-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orthopaedic Research®\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/jor.26113\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Research®","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jor.26113","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

外科医生通常使用长顺行髓内钉(aIMNs)固定老年患者股骨近端骨折。然而,种植体周围骨折的风险与aIMN终止水平的关系尚未得到研究。因此,我们使用7种不同长度的aIMN的有限元模型,研究了三种不同加载情况下ain钉尖终止水平与股骨远端骨折程度的相关性。这些材料被加载到合成骨质疏松性股骨的3D模型中,这些模型以单腿站立(SLS)加载,在股骨头处负重,以120 Nm的扭矩逆时针扭转(TOR)至失效,并以1000 mm/秒的速度模拟远端冲击/坠落(DIF)直接落在膝盖上。记录了SLS的最大应力以及TOR和DIF的失效元件百分比。对于SLS, aIMN尖端终止与最大应力不相关(ρ = 0.1429, p = 0.7599),数据无明显趋势。对于TOR,更近端的aIMN尖端终止与更大的失败面积百分比具有显著相关性(ρ = 0.9286, p = 0.0025)。对于DIF, aIMN尖端终止与失效元件百分比无关(ρ = -0.6071, p = 0.1482),但表现出统计学上显著的高斯关系(系数:a$ a$ = 2.22 (p = 1.13 × 10-3), b$ b$ = 58.61 (p = 1.89 × 10-5), c$ c$ = 17.46 (p = 1.79 × 10-3)),其中60 mm aIMN尖端终止显示出最大的失效面积百分比。因此,我们发现在股骨的更近端aIMN终止与TOR的失败程度之间存在很强的线性关系。干骺端终止与DIF的衰竭程度之间存在统计学上显著的高斯关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Risk of Distal Femur Fracture in Antegrade Intramedullary Nail Fixation of Proximal Femur Fractures: A Finite Element Study.

Surgeons often use long antegrade intramedullary nails (aIMNs) when fixing fractures of the proximal femur in geriatric patients. However, risk of peri-implant fracture in relation to aIMN termination level has not yet been studied. We therefore studied the correlation between aIMN nail tip termination level and extent of distal femur fracture in three different loading scenarios using finite element models of seven different length aIMNs. These were loaded into 3D models of synthetic osteoporotic femurs, which were loaded in single-leg stance (SLS) with body weight load at the femoral head, torsion (TOR) counterclockwise to failure with 120 Nm of torque, and distal impact/fall (DIF) simulating direct fall on the knees at 1000 mm/sec. The maximum stress in SLS and percentage of failed elements for TOR and DIF were recorded. For SLS, aIMN tip termination and maximum stress were not correlated (ρ = 0.1429, p = 0.7599) and there was no apparent trend in the data. For TOR, more proximal aIMN tip termination demonstrated a significant correlation with greater percentage of failed area (ρ = 0.9286, p = 0.0025). For DIF, aIMN tip termination was not correlated with the percentage of failed elements (ρ = -0.6071, p = 0.1482), but demonstrated a statistically significant Gaussian relationship (coeffs: a $a$  = 2.22 (p = 1.13 × 10-3), b $b$  = 58.61 (p = 1.89 × 10-5), c $c$  = 17.46 (p = 1.79 × 10-3)) where 60 mm aIMN tip termination demonstrated the greatest percentage of failed area. Therefore, we found a strong linear relationship between more proximal aIMN termination in the femur and extent of failure in TOR. There was a statistically significant Gaussian relationship between metaphyseal termination and extent of failure in DIF.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Orthopaedic Research®
Journal of Orthopaedic Research® 医学-整形外科
CiteScore
6.10
自引率
3.60%
发文量
261
审稿时长
3-6 weeks
期刊介绍: The Journal of Orthopaedic Research is the forum for the rapid publication of high quality reports of new information on the full spectrum of orthopaedic research, including life sciences, engineering, translational, and clinical studies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信