mCLIP ARC球关节假体的短期听力学结果-一项回顾性多中心研究。

IF 2.2
Dirk Beutner, N Bevis, S Arndt, C Offergeld, T Lenarz, S Busch, W Wolfram, L Niederwanger, B Loader, F Windisch, C Arnoldner, D Riss, E Schimanski, P M Zwittag, N Rubicz, P H Skarżyński, Ł Plichta, G Sprinzl, A Magele, L Taha, J Hornung
{"title":"mCLIP ARC球关节假体的短期听力学结果-一项回顾性多中心研究。","authors":"Dirk Beutner, N Bevis, S Arndt, C Offergeld, T Lenarz, S Busch, W Wolfram, L Niederwanger, B Loader, F Windisch, C Arnoldner, D Riss, E Schimanski, P M Zwittag, N Rubicz, P H Skarżyński, Ł Plichta, G Sprinzl, A Magele, L Taha, J Hornung","doi":"10.1007/s00405-025-09475-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This European multicentric, retrospective study aimed to analyze the short-term safety and effectiveness of the mCLIP ARC Ball Joint Prosthesis.</p><p><strong>Methods: </strong>Type III Tympanoplasty with implantation of a mCLIP-ARC Partial Prosthesis was performed. During patients' follow-up, ear microscopic evaluation and pure-tone audiometry were used for analysis. The post-operative pure-tone average of the frequencies 0.5, 1, 2 and 3 kHz (PTA4) were used for calculation of the air bone gap (ABG). Adverse events (AE) were evaluated during follow-up.</p><p><strong>Results: </strong>62 patients underwent implantation of the mCLIP-ARC Partial Prosthesis. 55 complete data sets were available for audiological examination. The mean follow-up time was 58 days. In two cases adverse events were recorded. The post-operative bone conduction (BC) PTA4 thresholds were stable in 96.4% of cases. The mean postoperative PTA-4 air-bone gap (ABG) was 16.5 ± 9.2 dB.</p><p><strong>Conclusion: </strong>Implantation of the mCLIP ARC partial prosthesis proves to be safe and reliable. Clinical data show satisfactory audiological results and demonstrate the effectiveness of the new middle ear prosthesis with a balanced ball joint.</p>","PeriodicalId":520614,"journal":{"name":"European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery","volume":" ","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2025-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Short-term audiological outcomes of the mCLIP ARC ball joint prosthesis- a retrospective multicenter study.\",\"authors\":\"Dirk Beutner, N Bevis, S Arndt, C Offergeld, T Lenarz, S Busch, W Wolfram, L Niederwanger, B Loader, F Windisch, C Arnoldner, D Riss, E Schimanski, P M Zwittag, N Rubicz, P H Skarżyński, Ł Plichta, G Sprinzl, A Magele, L Taha, J Hornung\",\"doi\":\"10.1007/s00405-025-09475-w\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This European multicentric, retrospective study aimed to analyze the short-term safety and effectiveness of the mCLIP ARC Ball Joint Prosthesis.</p><p><strong>Methods: </strong>Type III Tympanoplasty with implantation of a mCLIP-ARC Partial Prosthesis was performed. During patients' follow-up, ear microscopic evaluation and pure-tone audiometry were used for analysis. The post-operative pure-tone average of the frequencies 0.5, 1, 2 and 3 kHz (PTA4) were used for calculation of the air bone gap (ABG). Adverse events (AE) were evaluated during follow-up.</p><p><strong>Results: </strong>62 patients underwent implantation of the mCLIP-ARC Partial Prosthesis. 55 complete data sets were available for audiological examination. The mean follow-up time was 58 days. In two cases adverse events were recorded. The post-operative bone conduction (BC) PTA4 thresholds were stable in 96.4% of cases. The mean postoperative PTA-4 air-bone gap (ABG) was 16.5 ± 9.2 dB.</p><p><strong>Conclusion: </strong>Implantation of the mCLIP ARC partial prosthesis proves to be safe and reliable. Clinical data show satisfactory audiological results and demonstrate the effectiveness of the new middle ear prosthesis with a balanced ball joint.</p>\",\"PeriodicalId\":520614,\"journal\":{\"name\":\"European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2025-05-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s00405-025-09475-w\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s00405-025-09475-w","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:这项欧洲多中心回顾性研究旨在分析mCLIP ARC球形关节假体的短期安全性和有效性。方法:采用mCLIP-ARC部分假体植入III型鼓室成形术。随访时采用耳镜评价和纯音听力学进行分析。取术后频率0.5、1、2、3 kHz的纯音平均值(PTA4)计算气骨间隙(ABG)。随访期间评估不良事件(AE)。结果:62例患者行mCLIP-ARC部分假体植入术,获得55组完整听力学检查数据。平均随访时间58天。其中2例发生了不良事件。96.4%的患者术后骨传导(BC) PTA4阈值稳定。术后平均PTA-4气骨间隙(ABG)为16.5±9.2 dB。结论:mCLIP ARC部分假体植入术安全可靠。临床数据显示了令人满意的听力学结果,并证明了平衡球关节的新型中耳假体的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Short-term audiological outcomes of the mCLIP ARC ball joint prosthesis- a retrospective multicenter study.

Purpose: This European multicentric, retrospective study aimed to analyze the short-term safety and effectiveness of the mCLIP ARC Ball Joint Prosthesis.

Methods: Type III Tympanoplasty with implantation of a mCLIP-ARC Partial Prosthesis was performed. During patients' follow-up, ear microscopic evaluation and pure-tone audiometry were used for analysis. The post-operative pure-tone average of the frequencies 0.5, 1, 2 and 3 kHz (PTA4) were used for calculation of the air bone gap (ABG). Adverse events (AE) were evaluated during follow-up.

Results: 62 patients underwent implantation of the mCLIP-ARC Partial Prosthesis. 55 complete data sets were available for audiological examination. The mean follow-up time was 58 days. In two cases adverse events were recorded. The post-operative bone conduction (BC) PTA4 thresholds were stable in 96.4% of cases. The mean postoperative PTA-4 air-bone gap (ABG) was 16.5 ± 9.2 dB.

Conclusion: Implantation of the mCLIP ARC partial prosthesis proves to be safe and reliable. Clinical data show satisfactory audiological results and demonstrate the effectiveness of the new middle ear prosthesis with a balanced ball joint.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信