用M-TIO分级预测DSAEK移植物视觉结果的纹理界面不透明的筛选和分级。

IF 3 3区 医学 Q1 MEDICINE, GENERAL & INTERNAL
Marina S Chatzea, George D Kymionis, Dionysios G Vakalopoulos, Robert C O'Brien, Daniella Mora, Katrina Llanes, Elizabeth Fout, William Buras, Concetta Triglia, Rahul S Tonk, Sonia H Yoo
{"title":"用M-TIO分级预测DSAEK移植物视觉结果的纹理界面不透明的筛选和分级。","authors":"Marina S Chatzea, George D Kymionis, Dionysios G Vakalopoulos, Robert C O'Brien, Daniella Mora, Katrina Llanes, Elizabeth Fout, William Buras, Concetta Triglia, Rahul S Tonk, Sonia H Yoo","doi":"10.3390/diagnostics15101241","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background</b>: Textural Interface Opacities (TIOs) following Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) have become a notable postoperative concern. Several studies have attempted to identify associations between TIO development and intraoperative factors, including fluid dynamics, irregular stromal surfaces, viscoelastic usage, and recipient immunological responses. Despite these efforts, the precise etiology of TIO remains uncertain. TIO has not been considered predictable in the preoperative setting. Its detection has relied exclusively on slit-lamp biomicroscopy, a subjective approach lacking standardized diagnostic criteria, which limits diagnostic reliability and is highly susceptible to interobserver variability. <b>Methods</b>: Optical Coherence Tomography (OCT) images of DSAEK-processed corneal grafts, prepared using the same microkeratome and technique for transplantation at the Bascom Palmer Eye Institute, underwent blinded analysis using a newly developed grading scale termed \"M-TIO\". This analysis focused on DSAEK-processed grafts OCT images to evaluate and categorize the occurrence of TIO and assess the final visual acuity of the patients at the 1-year postoperative evaluation. <b>Results</b>: Based on the results, the M-TIO grading scale demonstrated strong predictive value, with higher grades on OCT of DSAEK lenticules consistently associated with worse postoperative visual acuity. The study included 221 donor corneas transplanted from 2019 to 2023. Greater TIO based on the \"M-TIO\" grading scale was associated with worse recipient logMAR VA (Mean 0.151 [99% CI: 0.077 to 0.225] for corneas with no TIO, increased to 0.680 [99% CI: 0.532 to 0.828] for corneas with the greatest TIO grade). These findings highlight the clinical utility of the M-TIO scale as an objective and reliable preoperative tool for assessing graft quality and predicting postoperative visual outcomes. <b>Conclusions</b>: This study introduces the \"M-TIO\" grading scale, which provides a standardized and objective method for evaluating Textural Interface Opacities in DSAEK grafts prior to transplantation. Our results demonstrate a clear association between the severity of TIO as graded by the M-TIO scale, and postoperative visual outcomes, with higher TIO grades correlating with worse visual acuity, emphasizing its value in improving graft selection, and clinical decision-making in DSAEK.</p>","PeriodicalId":11225,"journal":{"name":"Diagnostics","volume":"15 10","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12109586/pdf/","citationCount":"0","resultStr":"{\"title\":\"Screening and Grading of Textural Interface Opacities in DSAEK Grafts with the M-TIO Scale for Predicting Visual Outcomes.\",\"authors\":\"Marina S Chatzea, George D Kymionis, Dionysios G Vakalopoulos, Robert C O'Brien, Daniella Mora, Katrina Llanes, Elizabeth Fout, William Buras, Concetta Triglia, Rahul S Tonk, Sonia H Yoo\",\"doi\":\"10.3390/diagnostics15101241\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Background</b>: Textural Interface Opacities (TIOs) following Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) have become a notable postoperative concern. Several studies have attempted to identify associations between TIO development and intraoperative factors, including fluid dynamics, irregular stromal surfaces, viscoelastic usage, and recipient immunological responses. Despite these efforts, the precise etiology of TIO remains uncertain. TIO has not been considered predictable in the preoperative setting. Its detection has relied exclusively on slit-lamp biomicroscopy, a subjective approach lacking standardized diagnostic criteria, which limits diagnostic reliability and is highly susceptible to interobserver variability. <b>Methods</b>: Optical Coherence Tomography (OCT) images of DSAEK-processed corneal grafts, prepared using the same microkeratome and technique for transplantation at the Bascom Palmer Eye Institute, underwent blinded analysis using a newly developed grading scale termed \\\"M-TIO\\\". This analysis focused on DSAEK-processed grafts OCT images to evaluate and categorize the occurrence of TIO and assess the final visual acuity of the patients at the 1-year postoperative evaluation. <b>Results</b>: Based on the results, the M-TIO grading scale demonstrated strong predictive value, with higher grades on OCT of DSAEK lenticules consistently associated with worse postoperative visual acuity. The study included 221 donor corneas transplanted from 2019 to 2023. Greater TIO based on the \\\"M-TIO\\\" grading scale was associated with worse recipient logMAR VA (Mean 0.151 [99% CI: 0.077 to 0.225] for corneas with no TIO, increased to 0.680 [99% CI: 0.532 to 0.828] for corneas with the greatest TIO grade). These findings highlight the clinical utility of the M-TIO scale as an objective and reliable preoperative tool for assessing graft quality and predicting postoperative visual outcomes. <b>Conclusions</b>: This study introduces the \\\"M-TIO\\\" grading scale, which provides a standardized and objective method for evaluating Textural Interface Opacities in DSAEK grafts prior to transplantation. Our results demonstrate a clear association between the severity of TIO as graded by the M-TIO scale, and postoperative visual outcomes, with higher TIO grades correlating with worse visual acuity, emphasizing its value in improving graft selection, and clinical decision-making in DSAEK.</p>\",\"PeriodicalId\":11225,\"journal\":{\"name\":\"Diagnostics\",\"volume\":\"15 10\",\"pages\":\"\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-05-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12109586/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diagnostics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3390/diagnostics15101241\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/diagnostics15101241","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:Descemet剥离自动内皮角膜移植术(DSAEK)后的纹理界面混浊(TIOs)已成为术后值得关注的问题。一些研究试图确定TIO发展与术中因素之间的关系,包括流体动力学、不规则基质表面、粘弹性使用和受体免疫反应。尽管这些努力,TIO的确切病因仍然不确定。在术前,TIO不被认为是可预测的。它的检测完全依赖于裂隙灯生物显微镜,这是一种缺乏标准化诊断标准的主观方法,这限制了诊断的可靠性,并且极易受到观察者之间差异的影响。方法:在巴斯科姆帕尔默眼科研究所使用相同的微角刀和移植技术制备dsaek处理的角膜移植物的光学相干断层扫描(OCT)图像,使用新开发的分级量表“M-TIO”进行盲法分析。本分析主要通过dsaek处理的移植物OCT图像来评估和分类TIO的发生,并评估患者术后1年的最终视力。结果:M-TIO分级表具有较强的预测价值,DSAEK透镜体OCT分级越高,术后视力越差。该研究包括2019年至2023年期间移植的221例供体角膜。基于“M-TIO”分级量表的TIO越大,受者logMAR VA越差(无TIO的角膜平均值为0.151 [99% CI: 0.077至0.225],TIO等级最高的角膜平均值为0.680 [99% CI: 0.532至0.828])。这些发现强调了M-TIO量表作为评估移植物质量和预测术后视力结果的客观可靠的术前工具的临床应用。结论:本研究引入了“M-TIO”分级量表,为移植前评价DSAEK移植物的纹理界面不透明度提供了一种标准化、客观的方法。我们的研究结果表明,M-TIO分级的TIO严重程度与术后视力结果之间存在明显的关联,TIO等级越高,视力越差,强调了其在改善移植物选择和DSAEK临床决策方面的价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Screening and Grading of Textural Interface Opacities in DSAEK Grafts with the M-TIO Scale for Predicting Visual Outcomes.

Background: Textural Interface Opacities (TIOs) following Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) have become a notable postoperative concern. Several studies have attempted to identify associations between TIO development and intraoperative factors, including fluid dynamics, irregular stromal surfaces, viscoelastic usage, and recipient immunological responses. Despite these efforts, the precise etiology of TIO remains uncertain. TIO has not been considered predictable in the preoperative setting. Its detection has relied exclusively on slit-lamp biomicroscopy, a subjective approach lacking standardized diagnostic criteria, which limits diagnostic reliability and is highly susceptible to interobserver variability. Methods: Optical Coherence Tomography (OCT) images of DSAEK-processed corneal grafts, prepared using the same microkeratome and technique for transplantation at the Bascom Palmer Eye Institute, underwent blinded analysis using a newly developed grading scale termed "M-TIO". This analysis focused on DSAEK-processed grafts OCT images to evaluate and categorize the occurrence of TIO and assess the final visual acuity of the patients at the 1-year postoperative evaluation. Results: Based on the results, the M-TIO grading scale demonstrated strong predictive value, with higher grades on OCT of DSAEK lenticules consistently associated with worse postoperative visual acuity. The study included 221 donor corneas transplanted from 2019 to 2023. Greater TIO based on the "M-TIO" grading scale was associated with worse recipient logMAR VA (Mean 0.151 [99% CI: 0.077 to 0.225] for corneas with no TIO, increased to 0.680 [99% CI: 0.532 to 0.828] for corneas with the greatest TIO grade). These findings highlight the clinical utility of the M-TIO scale as an objective and reliable preoperative tool for assessing graft quality and predicting postoperative visual outcomes. Conclusions: This study introduces the "M-TIO" grading scale, which provides a standardized and objective method for evaluating Textural Interface Opacities in DSAEK grafts prior to transplantation. Our results demonstrate a clear association between the severity of TIO as graded by the M-TIO scale, and postoperative visual outcomes, with higher TIO grades correlating with worse visual acuity, emphasizing its value in improving graft selection, and clinical decision-making in DSAEK.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Diagnostics
Diagnostics Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
4.70
自引率
8.30%
发文量
2699
审稿时长
19.64 days
期刊介绍: Diagnostics (ISSN 2075-4418) is an international scholarly open access journal on medical diagnostics. It publishes original research articles, reviews, communications and short notes on the research and development of medical diagnostics. There is no restriction on the length of the papers. Our aim is to encourage scientists to publish their experimental and theoretical research in as much detail as possible. Full experimental and/or methodological details must be provided for research articles.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信