{"title":"FlexO2:一种患者控制的氧流量选择器,可提高长期氧疗(LTOT)的自主性和日常功能。","authors":"Michael Runold, Ingegerd Karlsson, Magda Borén","doi":"10.1186/s12931-025-03274-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Chronic respiratory insufficiency associated with severe resting hypoxemia necessitates long-term oxygen therapy (LTOT), yet existing devices often impede daily activities due to cumbersome flow adjustments, increasing reliance on caregivers. FlexO2 is a novel mechanical regulator that enables switching between preset oxygen flow rates for rest and activity. This proof-of-concept study evaluated its impact on patient autonomy, physical activity, and quality of life.</p><p><strong>Methods: </strong>In a consecutive, non-randomized pre-post intervention proof-of-concept study at Karolinska University Hospital, 26 patients on LTOT (median age 77; 69% COPD) used FlexO2 for three months. The device, worn around the neck, allowed patients to self-adjust oxygen doses without accessing the concentrator. Outcomes included ease of use measured by visual analogue scale (VAS), physical activity levels, COPD Assessment Test (CAT), EQ-5D-5 L index, and frequency of dose adjustments.</p><p><strong>Results: </strong>Ease of dose adjustment increased from a VAS score of 14 to 92 (p < 0.001), with 92% of patients reporting improved ease of adjustment (baseline 7.7%; p < 0.001). Daily adjustment frequency doubled (8 to 15; p = 0.001). Patient-reported activity capacity improved from a VAS of 11 to 80 (p < 0.001). Quality-of-life scores measured by VAS increased from 19 to 61 (p < 0.001), while CAT scores decreased from a median of 26.0 to 22.5 (p = 0.05). The EQ-5D-5 L index remained stable (0.68 to 0.70; p = 0.7), although 38% of patients showed individual improvements. Device usability was high (83% satisfaction), though 15% reported tubing tangling or airflow issues.</p><p><strong>Conclusion: </strong>FlexO2 significantly improved the ease of oxygen dose adjustment and physical activity capacity, potentially enhancing patient autonomy in LTOT. While overall patient-reported quality-of-life scores improved, objective quality-of-life outcomes remained stable. Further studies are warranted to explore long-term clinical outcomes and the potential impact on caregiver burden.</p>","PeriodicalId":49131,"journal":{"name":"Respiratory Research","volume":"26 1","pages":"200"},"PeriodicalIF":5.8000,"publicationDate":"2025-05-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12107881/pdf/","citationCount":"0","resultStr":"{\"title\":\"FlexO2: A patient-controlled oxygen flow selector improving autonomy and daily function in long-term oxygen therapy (LTOT).\",\"authors\":\"Michael Runold, Ingegerd Karlsson, Magda Borén\",\"doi\":\"10.1186/s12931-025-03274-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Chronic respiratory insufficiency associated with severe resting hypoxemia necessitates long-term oxygen therapy (LTOT), yet existing devices often impede daily activities due to cumbersome flow adjustments, increasing reliance on caregivers. FlexO2 is a novel mechanical regulator that enables switching between preset oxygen flow rates for rest and activity. This proof-of-concept study evaluated its impact on patient autonomy, physical activity, and quality of life.</p><p><strong>Methods: </strong>In a consecutive, non-randomized pre-post intervention proof-of-concept study at Karolinska University Hospital, 26 patients on LTOT (median age 77; 69% COPD) used FlexO2 for three months. The device, worn around the neck, allowed patients to self-adjust oxygen doses without accessing the concentrator. Outcomes included ease of use measured by visual analogue scale (VAS), physical activity levels, COPD Assessment Test (CAT), EQ-5D-5 L index, and frequency of dose adjustments.</p><p><strong>Results: </strong>Ease of dose adjustment increased from a VAS score of 14 to 92 (p < 0.001), with 92% of patients reporting improved ease of adjustment (baseline 7.7%; p < 0.001). Daily adjustment frequency doubled (8 to 15; p = 0.001). Patient-reported activity capacity improved from a VAS of 11 to 80 (p < 0.001). Quality-of-life scores measured by VAS increased from 19 to 61 (p < 0.001), while CAT scores decreased from a median of 26.0 to 22.5 (p = 0.05). The EQ-5D-5 L index remained stable (0.68 to 0.70; p = 0.7), although 38% of patients showed individual improvements. Device usability was high (83% satisfaction), though 15% reported tubing tangling or airflow issues.</p><p><strong>Conclusion: </strong>FlexO2 significantly improved the ease of oxygen dose adjustment and physical activity capacity, potentially enhancing patient autonomy in LTOT. While overall patient-reported quality-of-life scores improved, objective quality-of-life outcomes remained stable. Further studies are warranted to explore long-term clinical outcomes and the potential impact on caregiver burden.</p>\",\"PeriodicalId\":49131,\"journal\":{\"name\":\"Respiratory Research\",\"volume\":\"26 1\",\"pages\":\"200\"},\"PeriodicalIF\":5.8000,\"publicationDate\":\"2025-05-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12107881/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Respiratory Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12931-025-03274-x\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Respiratory Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12931-025-03274-x","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
FlexO2: A patient-controlled oxygen flow selector improving autonomy and daily function in long-term oxygen therapy (LTOT).
Background: Chronic respiratory insufficiency associated with severe resting hypoxemia necessitates long-term oxygen therapy (LTOT), yet existing devices often impede daily activities due to cumbersome flow adjustments, increasing reliance on caregivers. FlexO2 is a novel mechanical regulator that enables switching between preset oxygen flow rates for rest and activity. This proof-of-concept study evaluated its impact on patient autonomy, physical activity, and quality of life.
Methods: In a consecutive, non-randomized pre-post intervention proof-of-concept study at Karolinska University Hospital, 26 patients on LTOT (median age 77; 69% COPD) used FlexO2 for three months. The device, worn around the neck, allowed patients to self-adjust oxygen doses without accessing the concentrator. Outcomes included ease of use measured by visual analogue scale (VAS), physical activity levels, COPD Assessment Test (CAT), EQ-5D-5 L index, and frequency of dose adjustments.
Results: Ease of dose adjustment increased from a VAS score of 14 to 92 (p < 0.001), with 92% of patients reporting improved ease of adjustment (baseline 7.7%; p < 0.001). Daily adjustment frequency doubled (8 to 15; p = 0.001). Patient-reported activity capacity improved from a VAS of 11 to 80 (p < 0.001). Quality-of-life scores measured by VAS increased from 19 to 61 (p < 0.001), while CAT scores decreased from a median of 26.0 to 22.5 (p = 0.05). The EQ-5D-5 L index remained stable (0.68 to 0.70; p = 0.7), although 38% of patients showed individual improvements. Device usability was high (83% satisfaction), though 15% reported tubing tangling or airflow issues.
Conclusion: FlexO2 significantly improved the ease of oxygen dose adjustment and physical activity capacity, potentially enhancing patient autonomy in LTOT. While overall patient-reported quality-of-life scores improved, objective quality-of-life outcomes remained stable. Further studies are warranted to explore long-term clinical outcomes and the potential impact on caregiver burden.
期刊介绍:
Respiratory Research publishes high-quality clinical and basic research, review and commentary articles on all aspects of respiratory medicine and related diseases.
As the leading fully open access journal in the field, Respiratory Research provides an essential resource for pulmonologists, allergists, immunologists and other physicians, researchers, healthcare workers and medical students with worldwide dissemination of articles resulting in high visibility and generating international discussion.
Topics of specific interest include asthma, chronic obstructive pulmonary disease, cystic fibrosis, genetics, infectious diseases, interstitial lung diseases, lung development, lung tumors, occupational and environmental factors, pulmonary circulation, pulmonary pharmacology and therapeutics, respiratory immunology, respiratory physiology, and sleep-related respiratory problems.