一种坚韧的半干水凝胶电极,具有抗菌特性,用于长期可重复的无创脑电图采集。

IF 9.9 1区 工程技术 Q1 INSTRUMENTS & INSTRUMENTATION
Dongyang Wang, Hailing Xue, Long Xia, Zongqi Li, Yubo Zhao, Xinan Fan, Kai Sun, Huanan Wang, Timo Hamalainen, Chi Zhang, Fengyu Cong, Yanhua Li, Fei Song, Jiaqi Lin
{"title":"一种坚韧的半干水凝胶电极,具有抗菌特性,用于长期可重复的无创脑电图采集。","authors":"Dongyang Wang, Hailing Xue, Long Xia, Zongqi Li, Yubo Zhao, Xinan Fan, Kai Sun, Huanan Wang, Timo Hamalainen, Chi Zhang, Fengyu Cong, Yanhua Li, Fei Song, Jiaqi Lin","doi":"10.1038/s41378-025-00908-4","DOIUrl":null,"url":null,"abstract":"<p><p>Non-invasive brain-computer interfaces (NI-BCIs) have garnered significant attention due to their safety and wide range of applications. However, developing non-invasive electroencephalogram (EEG) electrodes that are highly sensitive, comfortable to wear, and reusable has been challenging due to the limitations of conventional electrodes. Here, we introduce a simple method for fabricating semi-dry hydrogel EEG electrodes with antibacterial properties, enabling long-term, repeatable acquisition of EEG. By utilizing N-acryloyl glycinamide and hydroxypropyltrimethyl ammonium chloride chitosan, we have prepared electrodes that not only possess good mechanical properties (compression modulus 65 kPa) and anti-fatigue properties but also exhibit superior antibacterial properties. These electrodes effectively inhibit the growth of both Gram-negative (E. coli) and Gram-positive (S. epidermidis) bacteria. Furthermore, the hydrogel maintains stable water retention properties, resulting in an average contact impedance of <400 Ω measured over 12 h, and an ionic conductivity of 0.39 mS cm<sup>-1</sup>. Cytotoxicity and skin irritation tests have confirmed the high biocompatibility of the hydrogel electrodes. In an N170 event-related potential (ERP) test on human volunteers, we successfully captured the expected ERP signal waveform and a high signal-to-noise ratio (20.02 dB), comparable to that of conventional wet electrodes. Moreover, contact impedance on the scalps remained below 100 kΩ for 12 h, while wet electrodes became unable to detect signals after 7-8 h due to dehydration. In summary, our hydrogel electrodes are capable of detecting ERPs over extended periods in an easy-to-use manner with antibacterial properties. This reduces the risk of bacterial infection associated with prolonged reuse and expands the potential of NI-BCIs in daily life.</p>","PeriodicalId":18560,"journal":{"name":"Microsystems & Nanoengineering","volume":"11 1","pages":"105"},"PeriodicalIF":9.9000,"publicationDate":"2025-05-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12106760/pdf/","citationCount":"0","resultStr":"{\"title\":\"A tough semi-dry hydrogel electrode with anti-bacterial properties for long-term repeatable non-invasive EEG acquisition.\",\"authors\":\"Dongyang Wang, Hailing Xue, Long Xia, Zongqi Li, Yubo Zhao, Xinan Fan, Kai Sun, Huanan Wang, Timo Hamalainen, Chi Zhang, Fengyu Cong, Yanhua Li, Fei Song, Jiaqi Lin\",\"doi\":\"10.1038/s41378-025-00908-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Non-invasive brain-computer interfaces (NI-BCIs) have garnered significant attention due to their safety and wide range of applications. However, developing non-invasive electroencephalogram (EEG) electrodes that are highly sensitive, comfortable to wear, and reusable has been challenging due to the limitations of conventional electrodes. Here, we introduce a simple method for fabricating semi-dry hydrogel EEG electrodes with antibacterial properties, enabling long-term, repeatable acquisition of EEG. By utilizing N-acryloyl glycinamide and hydroxypropyltrimethyl ammonium chloride chitosan, we have prepared electrodes that not only possess good mechanical properties (compression modulus 65 kPa) and anti-fatigue properties but also exhibit superior antibacterial properties. These electrodes effectively inhibit the growth of both Gram-negative (E. coli) and Gram-positive (S. epidermidis) bacteria. Furthermore, the hydrogel maintains stable water retention properties, resulting in an average contact impedance of <400 Ω measured over 12 h, and an ionic conductivity of 0.39 mS cm<sup>-1</sup>. Cytotoxicity and skin irritation tests have confirmed the high biocompatibility of the hydrogel electrodes. In an N170 event-related potential (ERP) test on human volunteers, we successfully captured the expected ERP signal waveform and a high signal-to-noise ratio (20.02 dB), comparable to that of conventional wet electrodes. Moreover, contact impedance on the scalps remained below 100 kΩ for 12 h, while wet electrodes became unable to detect signals after 7-8 h due to dehydration. In summary, our hydrogel electrodes are capable of detecting ERPs over extended periods in an easy-to-use manner with antibacterial properties. This reduces the risk of bacterial infection associated with prolonged reuse and expands the potential of NI-BCIs in daily life.</p>\",\"PeriodicalId\":18560,\"journal\":{\"name\":\"Microsystems & Nanoengineering\",\"volume\":\"11 1\",\"pages\":\"105\"},\"PeriodicalIF\":9.9000,\"publicationDate\":\"2025-05-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12106760/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microsystems & Nanoengineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1038/s41378-025-00908-4\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microsystems & Nanoengineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1038/s41378-025-00908-4","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

非侵入性脑机接口(NI-BCIs)因其安全性和广泛的应用而受到广泛关注。然而,由于传统电极的局限性,开发高度敏感、佩戴舒适、可重复使用的非侵入性脑电图(EEG)电极一直具有挑战性。在这里,我们介绍了一种简单的方法来制造具有抗菌特性的半干水凝胶脑电图电极,实现长期、可重复的脑电图采集。利用n -丙烯酰甘氨酸酰胺和羟丙基三甲基氯化铵壳聚糖制备的电极不仅具有良好的力学性能(压缩模量65 kPa)和抗疲劳性能,而且具有优异的抗菌性能。这些电极有效地抑制革兰氏阴性(大肠杆菌)和革兰氏阳性(表皮葡萄球菌)细菌的生长。此外,水凝胶保持稳定的保水性,导致平均接触阻抗为-1。细胞毒性和皮肤刺激试验证实了水凝胶电极的高生物相容性。在人类志愿者的N170事件相关电位(ERP)测试中,我们成功捕获了预期的ERP信号波形,并获得了与传统湿电极相当的高信噪比(20.02 dB)。此外,头皮上的接触阻抗在12小时内保持在100 kΩ以下,而湿电极在7-8小时后由于脱水而无法检测信号。总之,我们的水凝胶电极能够以一种易于使用的具有抗菌特性的方式在长时间内检测erp。这降低了与长期重复使用相关的细菌感染风险,并扩大了ni - bci在日常生活中的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A tough semi-dry hydrogel electrode with anti-bacterial properties for long-term repeatable non-invasive EEG acquisition.

Non-invasive brain-computer interfaces (NI-BCIs) have garnered significant attention due to their safety and wide range of applications. However, developing non-invasive electroencephalogram (EEG) electrodes that are highly sensitive, comfortable to wear, and reusable has been challenging due to the limitations of conventional electrodes. Here, we introduce a simple method for fabricating semi-dry hydrogel EEG electrodes with antibacterial properties, enabling long-term, repeatable acquisition of EEG. By utilizing N-acryloyl glycinamide and hydroxypropyltrimethyl ammonium chloride chitosan, we have prepared electrodes that not only possess good mechanical properties (compression modulus 65 kPa) and anti-fatigue properties but also exhibit superior antibacterial properties. These electrodes effectively inhibit the growth of both Gram-negative (E. coli) and Gram-positive (S. epidermidis) bacteria. Furthermore, the hydrogel maintains stable water retention properties, resulting in an average contact impedance of <400 Ω measured over 12 h, and an ionic conductivity of 0.39 mS cm-1. Cytotoxicity and skin irritation tests have confirmed the high biocompatibility of the hydrogel electrodes. In an N170 event-related potential (ERP) test on human volunteers, we successfully captured the expected ERP signal waveform and a high signal-to-noise ratio (20.02 dB), comparable to that of conventional wet electrodes. Moreover, contact impedance on the scalps remained below 100 kΩ for 12 h, while wet electrodes became unable to detect signals after 7-8 h due to dehydration. In summary, our hydrogel electrodes are capable of detecting ERPs over extended periods in an easy-to-use manner with antibacterial properties. This reduces the risk of bacterial infection associated with prolonged reuse and expands the potential of NI-BCIs in daily life.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Microsystems & Nanoengineering
Microsystems & Nanoengineering Materials Science-Materials Science (miscellaneous)
CiteScore
12.00
自引率
3.80%
发文量
123
审稿时长
20 weeks
期刊介绍: Microsystems & Nanoengineering is a comprehensive online journal that focuses on the field of Micro and Nano Electro Mechanical Systems (MEMS and NEMS). It provides a platform for researchers to share their original research findings and review articles in this area. The journal covers a wide range of topics, from fundamental research to practical applications. Published by Springer Nature, in collaboration with the Aerospace Information Research Institute, Chinese Academy of Sciences, and with the support of the State Key Laboratory of Transducer Technology, it is an esteemed publication in the field. As an open access journal, it offers free access to its content, allowing readers from around the world to benefit from the latest developments in MEMS and NEMS.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信