用位置敏感单片CLYC探测器成像中子

IF 1.4 3区 物理与天体物理 Q3 INSTRUMENTS & INSTRUMENTATION
J. Lerendegui-Marco , G. Cisterna , J. Hallam , V. Babiano-Suárez , J. Balibrea-Correa , D. Calvo , I. Ladarescu , G. de la Fuente , B. Gameiro , A. Sanchis-Moltó , P. Torres-Sánchez , C. Domingo-Pardo
{"title":"用位置敏感单片CLYC探测器成像中子","authors":"J. Lerendegui-Marco ,&nbsp;G. Cisterna ,&nbsp;J. Hallam ,&nbsp;V. Babiano-Suárez ,&nbsp;J. Balibrea-Correa ,&nbsp;D. Calvo ,&nbsp;I. Ladarescu ,&nbsp;G. de la Fuente ,&nbsp;B. Gameiro ,&nbsp;A. Sanchis-Moltó ,&nbsp;P. Torres-Sánchez ,&nbsp;C. Domingo-Pardo","doi":"10.1016/j.nima.2025.170594","DOIUrl":null,"url":null,"abstract":"<div><div>In this work, we have developed and characterized a position-sensitive CLYC detector that acts as the neutron imaging layer and <span><math><mi>γ</mi></math></span>-ray Compton scatterer of the novel dual Gamma-ray and Neutron Vision (GN-Vision) system, which aims at simultaneously obtaining information about the spatial origin of <span><math><mi>γ</mi></math></span>-ray and neutron sources. We first investigated the performance of two large 50 × 50 mm<sup>2</sup> monolithic CLYC crystals, 8 and 13 mm thick respectively, coupled to a pixelated SiPM in terms of energy resolution and neutron-gamma discrimination. The response of two different 95% <sup>6</sup>Li-enriched CLYC detectors coupled to an array of 8 × 8 SiPMs was studied in comparison to the results of a conventional photo-multiplier tube. An energy resolution of about 6% with PMT and 8% with SiPMs for the <sup>137</sup>Cs peak and a figure of merit of 3–4 for the neutron-gamma discrimination have been obtained. The spatial response of the CLYC-SiPM detector to <span><math><mi>γ</mi></math></span>-rays and neutrons has also been characterized using charge modulation-based multiplexing techniques based on a diode-coupled charge division circuit. Average resolutions close to 5 mm FWHM with good linearity are obtained in the transverse crystal plane. Last, this work presents the first proof-of-concept experiments of the neutron imaging capability using a neutron pinhole collimator attached to the developed position sensitive CLYC detector.</div></div>","PeriodicalId":19359,"journal":{"name":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","volume":"1079 ","pages":"Article 170594"},"PeriodicalIF":1.4000,"publicationDate":"2025-05-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Imaging neutrons with a position-sensitive monolithic CLYC detector\",\"authors\":\"J. Lerendegui-Marco ,&nbsp;G. Cisterna ,&nbsp;J. Hallam ,&nbsp;V. Babiano-Suárez ,&nbsp;J. Balibrea-Correa ,&nbsp;D. Calvo ,&nbsp;I. Ladarescu ,&nbsp;G. de la Fuente ,&nbsp;B. Gameiro ,&nbsp;A. Sanchis-Moltó ,&nbsp;P. Torres-Sánchez ,&nbsp;C. Domingo-Pardo\",\"doi\":\"10.1016/j.nima.2025.170594\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>In this work, we have developed and characterized a position-sensitive CLYC detector that acts as the neutron imaging layer and <span><math><mi>γ</mi></math></span>-ray Compton scatterer of the novel dual Gamma-ray and Neutron Vision (GN-Vision) system, which aims at simultaneously obtaining information about the spatial origin of <span><math><mi>γ</mi></math></span>-ray and neutron sources. We first investigated the performance of two large 50 × 50 mm<sup>2</sup> monolithic CLYC crystals, 8 and 13 mm thick respectively, coupled to a pixelated SiPM in terms of energy resolution and neutron-gamma discrimination. The response of two different 95% <sup>6</sup>Li-enriched CLYC detectors coupled to an array of 8 × 8 SiPMs was studied in comparison to the results of a conventional photo-multiplier tube. An energy resolution of about 6% with PMT and 8% with SiPMs for the <sup>137</sup>Cs peak and a figure of merit of 3–4 for the neutron-gamma discrimination have been obtained. The spatial response of the CLYC-SiPM detector to <span><math><mi>γ</mi></math></span>-rays and neutrons has also been characterized using charge modulation-based multiplexing techniques based on a diode-coupled charge division circuit. Average resolutions close to 5 mm FWHM with good linearity are obtained in the transverse crystal plane. Last, this work presents the first proof-of-concept experiments of the neutron imaging capability using a neutron pinhole collimator attached to the developed position sensitive CLYC detector.</div></div>\",\"PeriodicalId\":19359,\"journal\":{\"name\":\"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment\",\"volume\":\"1079 \",\"pages\":\"Article 170594\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2025-05-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S016890022500395X\",\"RegionNum\":3,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S016890022500395X","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

在这项工作中,我们开发并表征了一种位置敏感的CLYC探测器,该探测器作为新型双伽马射线和中子视觉(GN-Vision)系统的中子成像层和γ射线康普顿散射体,旨在同时获取γ射线和中子源的空间起源信息。我们首先研究了两个50 × 50 mm2的大型单片CLYC晶体,分别为8和13 mm厚,耦合到像素化SiPM在能量分辨率和中子-伽马辨别方面的性能。研究了两种不同的95%富集6li的CLYC探测器耦合到8 × 8 SiPMs阵列的响应,并与传统光倍增管的结果进行了比较。对137Cs峰,PMT和SiPMs分别获得了6%和8%的能量分辨和3-4的中子- γ鉴别值。CLYC-SiPM探测器对γ射线和中子的空间响应也利用基于二极管耦合电荷分割电路的电荷调制复用技术进行了表征。在横向晶面上获得了接近5 mm的平均分辨率和良好的线性度。最后,本工作提出了中子成像能力的第一个概念验证实验,该实验使用附加在开发的位置敏感CLYC探测器上的中子针孔准直器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Imaging neutrons with a position-sensitive monolithic CLYC detector
In this work, we have developed and characterized a position-sensitive CLYC detector that acts as the neutron imaging layer and γ-ray Compton scatterer of the novel dual Gamma-ray and Neutron Vision (GN-Vision) system, which aims at simultaneously obtaining information about the spatial origin of γ-ray and neutron sources. We first investigated the performance of two large 50 × 50 mm2 monolithic CLYC crystals, 8 and 13 mm thick respectively, coupled to a pixelated SiPM in terms of energy resolution and neutron-gamma discrimination. The response of two different 95% 6Li-enriched CLYC detectors coupled to an array of 8 × 8 SiPMs was studied in comparison to the results of a conventional photo-multiplier tube. An energy resolution of about 6% with PMT and 8% with SiPMs for the 137Cs peak and a figure of merit of 3–4 for the neutron-gamma discrimination have been obtained. The spatial response of the CLYC-SiPM detector to γ-rays and neutrons has also been characterized using charge modulation-based multiplexing techniques based on a diode-coupled charge division circuit. Average resolutions close to 5 mm FWHM with good linearity are obtained in the transverse crystal plane. Last, this work presents the first proof-of-concept experiments of the neutron imaging capability using a neutron pinhole collimator attached to the developed position sensitive CLYC detector.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.20
自引率
21.40%
发文量
787
审稿时长
1 months
期刊介绍: Section A of Nuclear Instruments and Methods in Physics Research publishes papers on design, manufacturing and performance of scientific instruments with an emphasis on large scale facilities. This includes the development of particle accelerators, ion sources, beam transport systems and target arrangements as well as the use of secondary phenomena such as synchrotron radiation and free electron lasers. It also includes all types of instrumentation for the detection and spectrometry of radiations from high energy processes and nuclear decays, as well as instrumentation for experiments at nuclear reactors. Specialized electronics for nuclear and other types of spectrometry as well as computerization of measurements and control systems in this area also find their place in the A section. Theoretical as well as experimental papers are accepted.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信