{"title":"全包传感片,集成无源混合器,用于紫外溶液","authors":"Seyed Hamid Safiabadi Tali,&nbsp;Muna Al-Kassawneh,&nbsp;Maryam Mansouri,&nbsp;Zubi Sadiq and Sana Jahanshahi-Anbuhi*,&nbsp;","doi":"10.1021/acssensors.4c0372610.1021/acssensors.4c03726","DOIUrl":null,"url":null,"abstract":"<p >Developing low-cost and easy-to-use point-of-care devices is necessary for timely disease diagnosis and health monitoring. Here, we introduce all-inclusive, tablet-based chemo/biosensors with rapid automixing features, capable of mixing in highly viscous solutions with viscosities up to 1700 mPa·s. These tablets are created using a simple powder compression method and contain all necessary reagents to perform assays in a “drop-and-detect” manner, without the need for vigorous shaking or vortex mixing. As proof of concept, we demonstrated the applicability of our Speedy tablets for detecting nitrite in human saliva, a challenging medium due to its viscosity. The strong mixing capability of the proposed tablets ensured consistent and reliable results across range of viscosities, from low to high, while delivering an excellent detection range of 0.03–1.50 mg/dL, covering nitrite levels in human saliva. Additionally, we developed a straightforward method to encapsulate enzymes in trehalose, making them bulkier and more stable using only a mist sprayer, nonstick tray, and spatula, eliminating the need for expensive equipment. This approach allowed us to incorporate small amounts of enzymes into tablet formulations and fabricate the first automixing tablet biosensor. These biosensors were used for the bienzymatic detection of glucose in real human urine within the biologically relevant range of 0.3–2.5 mM, indicating the compatibility of automixing tablets with bioreagents. Each tablet costs less than $0.30 to produce and remains stable for at least one month at room temperature. The affordability and convenience of our tablets make them a valuable addition to the array of diagnostic tools.</p>","PeriodicalId":24,"journal":{"name":"ACS Sensors","volume":"10 5","pages":"3493–3503 3493–3503"},"PeriodicalIF":9.1000,"publicationDate":"2025-05-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"All-Inclusive Sensing Tablet with Integrated Passive Mixer for Ultraviscous Solutions\",\"authors\":\"Seyed Hamid Safiabadi Tali,&nbsp;Muna Al-Kassawneh,&nbsp;Maryam Mansouri,&nbsp;Zubi Sadiq and Sana Jahanshahi-Anbuhi*,&nbsp;\",\"doi\":\"10.1021/acssensors.4c0372610.1021/acssensors.4c03726\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >Developing low-cost and easy-to-use point-of-care devices is necessary for timely disease diagnosis and health monitoring. Here, we introduce all-inclusive, tablet-based chemo/biosensors with rapid automixing features, capable of mixing in highly viscous solutions with viscosities up to 1700 mPa·s. These tablets are created using a simple powder compression method and contain all necessary reagents to perform assays in a “drop-and-detect” manner, without the need for vigorous shaking or vortex mixing. As proof of concept, we demonstrated the applicability of our Speedy tablets for detecting nitrite in human saliva, a challenging medium due to its viscosity. The strong mixing capability of the proposed tablets ensured consistent and reliable results across range of viscosities, from low to high, while delivering an excellent detection range of 0.03–1.50 mg/dL, covering nitrite levels in human saliva. Additionally, we developed a straightforward method to encapsulate enzymes in trehalose, making them bulkier and more stable using only a mist sprayer, nonstick tray, and spatula, eliminating the need for expensive equipment. This approach allowed us to incorporate small amounts of enzymes into tablet formulations and fabricate the first automixing tablet biosensor. These biosensors were used for the bienzymatic detection of glucose in real human urine within the biologically relevant range of 0.3–2.5 mM, indicating the compatibility of automixing tablets with bioreagents. Each tablet costs less than $0.30 to produce and remains stable for at least one month at room temperature. The affordability and convenience of our tablets make them a valuable addition to the array of diagnostic tools.</p>\",\"PeriodicalId\":24,\"journal\":{\"name\":\"ACS Sensors\",\"volume\":\"10 5\",\"pages\":\"3493–3503 3493–3503\"},\"PeriodicalIF\":9.1000,\"publicationDate\":\"2025-05-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Sensors\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://pubs.acs.org/doi/10.1021/acssensors.4c03726\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Sensors","FirstCategoryId":"92","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acssensors.4c03726","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

开发低成本和易于使用的护理点设备对于及时诊断疾病和监测健康是必要的。在这里,我们介绍了具有快速自动混合功能的全包式片剂化学/生物传感器,能够在粘度高达1700 mPa·s的高粘性溶液中混合。这些药片是用简单的粉末压缩法制成的,含有所有必要的试剂,以“滴下检测”的方式进行分析,不需要剧烈摇动或漩涡混合。作为概念证明,我们展示了我们的快速片剂用于检测人类唾液中的亚硝酸盐的适用性,由于其粘度,这是一种具有挑战性的介质。所述片剂的强大混合能力确保了从低到高粘度范围内一致可靠的结果,同时提供了0.03-1.50 mg/dL的出色检测范围,涵盖了人类唾液中的亚硝酸盐水平。此外,我们开发了一种简单的方法来封装海藻糖中的酶,使它们更大,更稳定,只使用喷雾器,不粘锅和抹刀,消除了对昂贵设备的需要。这种方法使我们能够将少量的酶结合到片剂配方中,并制造出第一个自动混合片剂生物传感器。这些生物传感器用于在0.3-2.5 mM的生物学相关范围内对真实人尿中的葡萄糖进行双酶检测,表明自动混合片与生物试剂的相容性。每片药片的生产成本不到0.30美元,在室温下至少可以保持一个月的稳定性。我们的平板电脑价格实惠,使用方便,使其成为诊断工具系列中有价值的补充。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

All-Inclusive Sensing Tablet with Integrated Passive Mixer for Ultraviscous Solutions

All-Inclusive Sensing Tablet with Integrated Passive Mixer for Ultraviscous Solutions

Developing low-cost and easy-to-use point-of-care devices is necessary for timely disease diagnosis and health monitoring. Here, we introduce all-inclusive, tablet-based chemo/biosensors with rapid automixing features, capable of mixing in highly viscous solutions with viscosities up to 1700 mPa·s. These tablets are created using a simple powder compression method and contain all necessary reagents to perform assays in a “drop-and-detect” manner, without the need for vigorous shaking or vortex mixing. As proof of concept, we demonstrated the applicability of our Speedy tablets for detecting nitrite in human saliva, a challenging medium due to its viscosity. The strong mixing capability of the proposed tablets ensured consistent and reliable results across range of viscosities, from low to high, while delivering an excellent detection range of 0.03–1.50 mg/dL, covering nitrite levels in human saliva. Additionally, we developed a straightforward method to encapsulate enzymes in trehalose, making them bulkier and more stable using only a mist sprayer, nonstick tray, and spatula, eliminating the need for expensive equipment. This approach allowed us to incorporate small amounts of enzymes into tablet formulations and fabricate the first automixing tablet biosensor. These biosensors were used for the bienzymatic detection of glucose in real human urine within the biologically relevant range of 0.3–2.5 mM, indicating the compatibility of automixing tablets with bioreagents. Each tablet costs less than $0.30 to produce and remains stable for at least one month at room temperature. The affordability and convenience of our tablets make them a valuable addition to the array of diagnostic tools.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Sensors
ACS Sensors Chemical Engineering-Bioengineering
CiteScore
14.50
自引率
3.40%
发文量
372
期刊介绍: ACS Sensors is a peer-reviewed research journal that focuses on the dissemination of new and original knowledge in the field of sensor science, particularly those that selectively sense chemical or biological species or processes. The journal covers a broad range of topics, including but not limited to biosensors, chemical sensors, gas sensors, intracellular sensors, single molecule sensors, cell chips, and microfluidic devices. It aims to publish articles that address conceptual advances in sensing technology applicable to various types of analytes or application papers that report on the use of existing sensing concepts in new ways or for new analytes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信