Jaehyung Jeon, Heeseon Choi, Gyeo-Re Han, Rajesh Ghosh, Barath Palanisamy, Dino Di Carlo, Aydogan Ozcan* and Sungsu Park*,
{"title":"用于体外诊断和环境监测的基于纸张的垂直流动试验","authors":"Jaehyung Jeon, Heeseon Choi, Gyeo-Re Han, Rajesh Ghosh, Barath Palanisamy, Dino Di Carlo, Aydogan Ozcan* and Sungsu Park*, ","doi":"10.1021/acssensors.5c0066810.1021/acssensors.5c00668","DOIUrl":null,"url":null,"abstract":"<p >Microfluidic paper-based analytical devices (μPADs) are powerful tools for diagnostic and environmental monitoring. Being affordable and portable, μPADs enable rapid detection of small molecules, heavy metals, and biomolecules, thereby decentralizing diagnostics and expanding biosensor accessibility. However, the reliance on two-dimensional fluid flow restricts the utility of conventional μPADs, presenting challenges for applications that require simultaneous multibiomarker analysis from a single sample. Vertical flow paper-based analytical devices (VF-μPADs) overcome this challenge by allowing axial fluid movement through paper stacks, offering several advantages, including (1) enhanced multiplexing capabilities, (2) reduced hook effect for improved accuracy, and (3) shorter assay times. This review provides an overview of VF-μPADs technologies, exploring structural and functional performance trade-offs between VF-μPADs and conventional lateral flow systems. The sensing performance, fabrication methods, and applications in in vitro diagnostics and environmental monitoring are discussed. Furthermore, critical challenges─such as fabrication complexity, data analysis, and scalability─are addressed, along with proposed strategies for mitigating these barriers to facilitate broader adoption. By examining these strengths and challenges, this review presents the potential of VF-μPADs to advance point-of-care testing, particularly in resource-limited settings.</p>","PeriodicalId":24,"journal":{"name":"ACS Sensors","volume":"10 5","pages":"3317–3339 3317–3339"},"PeriodicalIF":8.2000,"publicationDate":"2025-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Paper-Based Vertical Flow Assays for in Vitro Diagnostics and Environmental Monitoring\",\"authors\":\"Jaehyung Jeon, Heeseon Choi, Gyeo-Re Han, Rajesh Ghosh, Barath Palanisamy, Dino Di Carlo, Aydogan Ozcan* and Sungsu Park*, \",\"doi\":\"10.1021/acssensors.5c0066810.1021/acssensors.5c00668\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >Microfluidic paper-based analytical devices (μPADs) are powerful tools for diagnostic and environmental monitoring. Being affordable and portable, μPADs enable rapid detection of small molecules, heavy metals, and biomolecules, thereby decentralizing diagnostics and expanding biosensor accessibility. However, the reliance on two-dimensional fluid flow restricts the utility of conventional μPADs, presenting challenges for applications that require simultaneous multibiomarker analysis from a single sample. Vertical flow paper-based analytical devices (VF-μPADs) overcome this challenge by allowing axial fluid movement through paper stacks, offering several advantages, including (1) enhanced multiplexing capabilities, (2) reduced hook effect for improved accuracy, and (3) shorter assay times. This review provides an overview of VF-μPADs technologies, exploring structural and functional performance trade-offs between VF-μPADs and conventional lateral flow systems. The sensing performance, fabrication methods, and applications in in vitro diagnostics and environmental monitoring are discussed. Furthermore, critical challenges─such as fabrication complexity, data analysis, and scalability─are addressed, along with proposed strategies for mitigating these barriers to facilitate broader adoption. By examining these strengths and challenges, this review presents the potential of VF-μPADs to advance point-of-care testing, particularly in resource-limited settings.</p>\",\"PeriodicalId\":24,\"journal\":{\"name\":\"ACS Sensors\",\"volume\":\"10 5\",\"pages\":\"3317–3339 3317–3339\"},\"PeriodicalIF\":8.2000,\"publicationDate\":\"2025-05-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Sensors\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://pubs.acs.org/doi/10.1021/acssensors.5c00668\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Sensors","FirstCategoryId":"92","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acssensors.5c00668","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Paper-Based Vertical Flow Assays for in Vitro Diagnostics and Environmental Monitoring
Microfluidic paper-based analytical devices (μPADs) are powerful tools for diagnostic and environmental monitoring. Being affordable and portable, μPADs enable rapid detection of small molecules, heavy metals, and biomolecules, thereby decentralizing diagnostics and expanding biosensor accessibility. However, the reliance on two-dimensional fluid flow restricts the utility of conventional μPADs, presenting challenges for applications that require simultaneous multibiomarker analysis from a single sample. Vertical flow paper-based analytical devices (VF-μPADs) overcome this challenge by allowing axial fluid movement through paper stacks, offering several advantages, including (1) enhanced multiplexing capabilities, (2) reduced hook effect for improved accuracy, and (3) shorter assay times. This review provides an overview of VF-μPADs technologies, exploring structural and functional performance trade-offs between VF-μPADs and conventional lateral flow systems. The sensing performance, fabrication methods, and applications in in vitro diagnostics and environmental monitoring are discussed. Furthermore, critical challenges─such as fabrication complexity, data analysis, and scalability─are addressed, along with proposed strategies for mitigating these barriers to facilitate broader adoption. By examining these strengths and challenges, this review presents the potential of VF-μPADs to advance point-of-care testing, particularly in resource-limited settings.
期刊介绍:
ACS Sensors is a peer-reviewed research journal that focuses on the dissemination of new and original knowledge in the field of sensor science, particularly those that selectively sense chemical or biological species or processes. The journal covers a broad range of topics, including but not limited to biosensors, chemical sensors, gas sensors, intracellular sensors, single molecule sensors, cell chips, and microfluidic devices. It aims to publish articles that address conceptual advances in sensing technology applicable to various types of analytes or application papers that report on the use of existing sensing concepts in new ways or for new analytes.