{"title":"B型主动脉夹层假腔血栓形成的影响因素:单中心回顾性研究。","authors":"Qian-Hui Tang, Han Yang, Zhong Qin, Qiu-Ning Lin, Ming Hu, Xiao Qin, Jing Chen","doi":"10.1515/med-2025-1179","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate the factors associated with false lumen thrombosis in preoperative type B aortic dissection (TBAD) patients.</p><p><strong>Methods: </strong>Between January 2008 and December 2017, TBAD patients were evaluated. Participants were divided into patent, partial thrombosis, and complete thrombosis groups according to the status of the false lumen. Univariate analysis and logistic regression analysis were used to identify the factors associated with false lumen thrombosis.</p><p><strong>Results: </strong>A total of 285 participants fulfilled our inclusion criteria. Patients in the complete thrombosis group were significantly older than those in the partial thrombosis and patent groups (59 ± 10 vs 53 ± 11 and 50 ± 11 years, respectively), and combined shorter dissection lengths (290 ± 101 vs 354 ± 92 and 351 ± 102 mm, respectively). The following factors were associated with partial thrombosis of the false lumen with an odds ratio (OR) <1: primary tear size (OR, 0.96; 95% confidence interval [CI], 0.93-0.99; <i>p</i> = 0.03), last tear size (OR, 0.93; 95% CI, 0.87-0.99; <i>p</i> = 0.04), and the total number of tears (OR, 0.87; 95% CI, 0.78-0.98; <i>p</i> = 0.02).</p><p><strong>Conclusions: </strong>TBAD patients older than 59 years or with aortic dissection lengths of less than 290 mm were more likely to have a thrombosed false lumen.</p>","PeriodicalId":19715,"journal":{"name":"Open Medicine","volume":"20 1","pages":"20251179"},"PeriodicalIF":1.6000,"publicationDate":"2025-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12086627/pdf/","citationCount":"0","resultStr":"{\"title\":\"Influencing factors of false lumen thrombosis in type B aortic dissection: A single-center retrospective study.\",\"authors\":\"Qian-Hui Tang, Han Yang, Zhong Qin, Qiu-Ning Lin, Ming Hu, Xiao Qin, Jing Chen\",\"doi\":\"10.1515/med-2025-1179\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To evaluate the factors associated with false lumen thrombosis in preoperative type B aortic dissection (TBAD) patients.</p><p><strong>Methods: </strong>Between January 2008 and December 2017, TBAD patients were evaluated. Participants were divided into patent, partial thrombosis, and complete thrombosis groups according to the status of the false lumen. Univariate analysis and logistic regression analysis were used to identify the factors associated with false lumen thrombosis.</p><p><strong>Results: </strong>A total of 285 participants fulfilled our inclusion criteria. Patients in the complete thrombosis group were significantly older than those in the partial thrombosis and patent groups (59 ± 10 vs 53 ± 11 and 50 ± 11 years, respectively), and combined shorter dissection lengths (290 ± 101 vs 354 ± 92 and 351 ± 102 mm, respectively). The following factors were associated with partial thrombosis of the false lumen with an odds ratio (OR) <1: primary tear size (OR, 0.96; 95% confidence interval [CI], 0.93-0.99; <i>p</i> = 0.03), last tear size (OR, 0.93; 95% CI, 0.87-0.99; <i>p</i> = 0.04), and the total number of tears (OR, 0.87; 95% CI, 0.78-0.98; <i>p</i> = 0.02).</p><p><strong>Conclusions: </strong>TBAD patients older than 59 years or with aortic dissection lengths of less than 290 mm were more likely to have a thrombosed false lumen.</p>\",\"PeriodicalId\":19715,\"journal\":{\"name\":\"Open Medicine\",\"volume\":\"20 1\",\"pages\":\"20251179\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2025-05-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12086627/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Open Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1515/med-2025-1179\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1515/med-2025-1179","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
摘要
目的:探讨术前B型主动脉夹层(TBAD)患者假腔血栓形成的相关因素。方法:2008年1月至2017年12月,对TBAD患者进行评估。根据假腔的状态将参与者分为未通畅血栓、部分血栓和完全血栓组。采用单因素分析和logistic回归分析确定与假腔血栓形成相关的因素。结果:共有285名受试者符合我们的纳入标准。完全血栓组患者年龄明显大于部分血栓组和未闭组(分别为59±10岁vs 53±11岁和50±11岁),且夹层长度较短(分别为290±101 mm vs 354±92 mm和351±102 mm)。以下因素与假腔部分血栓形成相关,优势比(OR) p = 0.03),最后撕裂大小(OR, 0.93;95% ci, 0.87-0.99;p = 0.04),泪点总数(OR, 0.87;95% ci, 0.78-0.98;P = 0.02)。结论:年龄大于59岁或主动脉夹层长度小于290毫米的TBAD患者更有可能有血栓形成的假腔。
Influencing factors of false lumen thrombosis in type B aortic dissection: A single-center retrospective study.
Objectives: To evaluate the factors associated with false lumen thrombosis in preoperative type B aortic dissection (TBAD) patients.
Methods: Between January 2008 and December 2017, TBAD patients were evaluated. Participants were divided into patent, partial thrombosis, and complete thrombosis groups according to the status of the false lumen. Univariate analysis and logistic regression analysis were used to identify the factors associated with false lumen thrombosis.
Results: A total of 285 participants fulfilled our inclusion criteria. Patients in the complete thrombosis group were significantly older than those in the partial thrombosis and patent groups (59 ± 10 vs 53 ± 11 and 50 ± 11 years, respectively), and combined shorter dissection lengths (290 ± 101 vs 354 ± 92 and 351 ± 102 mm, respectively). The following factors were associated with partial thrombosis of the false lumen with an odds ratio (OR) <1: primary tear size (OR, 0.96; 95% confidence interval [CI], 0.93-0.99; p = 0.03), last tear size (OR, 0.93; 95% CI, 0.87-0.99; p = 0.04), and the total number of tears (OR, 0.87; 95% CI, 0.78-0.98; p = 0.02).
Conclusions: TBAD patients older than 59 years or with aortic dissection lengths of less than 290 mm were more likely to have a thrombosed false lumen.
期刊介绍:
Open Medicine is an open access journal that provides users with free, instant, and continued access to all content worldwide. The primary goal of the journal has always been a focus on maintaining the high quality of its published content. Its mission is to facilitate the exchange of ideas between medical science researchers from different countries. Papers connected to all fields of medicine and public health are welcomed. Open Medicine accepts submissions of research articles, reviews, case reports, letters to editor and book reviews.