臭氧水消毒后有机硅印模材料尺寸稳定性和精度的体外研究

Q3 Dentistry
Frontiers in Dentistry Pub Date : 2025-02-04 eCollection Date: 2025-01-01 DOI:10.18502/fid.v22i5.17838
Abinaya Kutralanathan, Ahila Singaravel Chidambaranathan, Muthukumar Balasubramaniam
{"title":"臭氧水消毒后有机硅印模材料尺寸稳定性和精度的体外研究","authors":"Abinaya Kutralanathan, Ahila Singaravel Chidambaranathan, Muthukumar Balasubramaniam","doi":"10.18502/fid.v22i5.17838","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objectives:</b> This study evaluated the effect of ozone water disinfection on dimensional stability and accuracy of silicone impression materials. <b>Materials and Methods:</b> According to ISO-4823, a stainless-steel die was fabricated for this in vitro study. Three horizontal parallel lines, namely x, y, and z (25, 50, and 75µm in width and 25mm in length) running perpendicular to two vertical lines, namely D1 and D2 (0.075±0.008mm wide), were created on the superior surface of the die. Group A served as the control group with no disinfection. Disinfection was performed with 2% glutaraldehyde in group B, 5.25% sodium hypochlorite in group C, and ozone water in group D for 10 minutes. Totally, 60 samples were fabricated. The silicone impression samples were allowed to polymerize in a thermostatically controlled water bath at 35±1ºC for 10 minutes. The dimensional stability and accuracy of the silicone impression samples were evaluated by using a video measuring microscope and an optical microscope. Data were analyzed by two-way ANOVA followed by post-hoc analysis with the Scheffe test (alpha=0.05). <b>Results:</b> The highest dimensional stability (25.01mm) and accuracy (25.02µm) were seen in addition silicone putty and light body impression with ozone water disinfection, and the lowest parameters were seen in condensation silicon putty and light body disinfected with 2% glutaraldehyde (24.87mm and 24.88 µm, respectively); this difference was statistically significant (P<0.001). <b>Conclusion:</b> Ozone water disinfection caused minimal changes in dimensional stability and accuracy when compared to 2% glutaraldehyde and 5.25% sodium hypochlorite disinfection.</p>","PeriodicalId":12445,"journal":{"name":"Frontiers in Dentistry","volume":"22 ","pages":"5"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12086316/pdf/","citationCount":"0","resultStr":"{\"title\":\"Dimensional Stability and Accuracy of Silicone Impression Materials after Ozone Water Disinfection: An In Vitro Study.\",\"authors\":\"Abinaya Kutralanathan, Ahila Singaravel Chidambaranathan, Muthukumar Balasubramaniam\",\"doi\":\"10.18502/fid.v22i5.17838\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Objectives:</b> This study evaluated the effect of ozone water disinfection on dimensional stability and accuracy of silicone impression materials. <b>Materials and Methods:</b> According to ISO-4823, a stainless-steel die was fabricated for this in vitro study. Three horizontal parallel lines, namely x, y, and z (25, 50, and 75µm in width and 25mm in length) running perpendicular to two vertical lines, namely D1 and D2 (0.075±0.008mm wide), were created on the superior surface of the die. Group A served as the control group with no disinfection. Disinfection was performed with 2% glutaraldehyde in group B, 5.25% sodium hypochlorite in group C, and ozone water in group D for 10 minutes. Totally, 60 samples were fabricated. The silicone impression samples were allowed to polymerize in a thermostatically controlled water bath at 35±1ºC for 10 minutes. The dimensional stability and accuracy of the silicone impression samples were evaluated by using a video measuring microscope and an optical microscope. Data were analyzed by two-way ANOVA followed by post-hoc analysis with the Scheffe test (alpha=0.05). <b>Results:</b> The highest dimensional stability (25.01mm) and accuracy (25.02µm) were seen in addition silicone putty and light body impression with ozone water disinfection, and the lowest parameters were seen in condensation silicon putty and light body disinfected with 2% glutaraldehyde (24.87mm and 24.88 µm, respectively); this difference was statistically significant (P<0.001). <b>Conclusion:</b> Ozone water disinfection caused minimal changes in dimensional stability and accuracy when compared to 2% glutaraldehyde and 5.25% sodium hypochlorite disinfection.</p>\",\"PeriodicalId\":12445,\"journal\":{\"name\":\"Frontiers in Dentistry\",\"volume\":\"22 \",\"pages\":\"5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-02-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12086316/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Frontiers in Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18502/fid.v22i5.17838\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18502/fid.v22i5.17838","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

目的:研究臭氧水消毒对硅胶印模材料尺寸稳定性和精度的影响。材料与方法:根据ISO-4823标准制作不锈钢体外实验模具。在模具上表面形成三条水平平行线,分别为x、y、z(宽度分别为25、50、75µm,长度分别为25mm),垂直于两条垂直线D1、D2(宽度为0.075±0.008mm)。A组为对照组,不进行消毒。B组用2%戊二醛消毒,C组用5.25%次氯酸钠消毒,D组用臭氧水消毒10分钟。共制作了60个样品。硅胶印模样品在35±1℃的恒温控制水浴中聚合10分钟。采用视频测量显微镜和光学显微镜对硅胶印模样品的尺寸稳定性和精度进行了评价。数据采用双因素方差分析和事后分析,采用Scheffe检验(α =0.05)。结果:臭氧水消毒硅灰和光体印模的尺寸稳定性最高(25.01mm),精度最高(25.02µm), 2%戊二醛消毒冷凝硅灰和光体印模的尺寸稳定性最低(24.87mm和24.88µm);结论:与2%戊二醛和5.25%次氯酸钠消毒相比,臭氧水消毒的尺寸稳定性和准确性变化很小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dimensional Stability and Accuracy of Silicone Impression Materials after Ozone Water Disinfection: An In Vitro Study.

Objectives: This study evaluated the effect of ozone water disinfection on dimensional stability and accuracy of silicone impression materials. Materials and Methods: According to ISO-4823, a stainless-steel die was fabricated for this in vitro study. Three horizontal parallel lines, namely x, y, and z (25, 50, and 75µm in width and 25mm in length) running perpendicular to two vertical lines, namely D1 and D2 (0.075±0.008mm wide), were created on the superior surface of the die. Group A served as the control group with no disinfection. Disinfection was performed with 2% glutaraldehyde in group B, 5.25% sodium hypochlorite in group C, and ozone water in group D for 10 minutes. Totally, 60 samples were fabricated. The silicone impression samples were allowed to polymerize in a thermostatically controlled water bath at 35±1ºC for 10 minutes. The dimensional stability and accuracy of the silicone impression samples were evaluated by using a video measuring microscope and an optical microscope. Data were analyzed by two-way ANOVA followed by post-hoc analysis with the Scheffe test (alpha=0.05). Results: The highest dimensional stability (25.01mm) and accuracy (25.02µm) were seen in addition silicone putty and light body impression with ozone water disinfection, and the lowest parameters were seen in condensation silicon putty and light body disinfected with 2% glutaraldehyde (24.87mm and 24.88 µm, respectively); this difference was statistically significant (P<0.001). Conclusion: Ozone water disinfection caused minimal changes in dimensional stability and accuracy when compared to 2% glutaraldehyde and 5.25% sodium hypochlorite disinfection.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Frontiers in Dentistry
Frontiers in Dentistry Dentistry-General Dentistry
CiteScore
1.00
自引率
0.00%
发文量
34
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信