基于核磁共振的伪CT序列作为产科骨盆测量CT的无辐射替代方案:概念验证研究。

IF 3.7 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Caroline Chabot, Mathilde Haegeman, Eya Chaouch, Dana Dumitriu, Renaud Menten, Patricia Steenhaut, Pierre Bernard, Perrine Triqueneaux, Nicolas Michoux, Frédéric E Lecouvet
{"title":"基于核磁共振的伪CT序列作为产科骨盆测量CT的无辐射替代方案:概念验证研究。","authors":"Caroline Chabot, Mathilde Haegeman, Eya Chaouch, Dana Dumitriu, Renaud Menten, Patricia Steenhaut, Pierre Bernard, Perrine Triqueneaux, Nicolas Michoux, Frédéric E Lecouvet","doi":"10.1186/s41747-025-00585-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Pelvimetry is essential in obstetrics for delivery planning. While computed tomography (CT) is the standard, magnetic resonance imaging (MRI) offers a radiation-free alternative with zero echo time (ZTE) and black bone (BB) sequences providing high bone-to-soft tissue contrast within short scan times. This proof-of-concept study evaluates the reliability of these sequences and the agreement with CT for pelvimetry in a predominantly elderly population.</p><p><strong>Methods: </strong>This retrospective study included 21 female patients who underwent 3-T whole-body MRI including ZTE and BB sequences and <sup>18</sup>fluorodeoxyglucose (<sup>18</sup>F-FDG) positron emission tomography (PET)/CT with optimized low-dose whole-body CT. Obstetric conjugate diameter (OCD), interspinous diameter (ISD), and median transverse diameter (MTD) were measured by five radiologists. Intra-reader, inter-reader, and inter-technique agreement were assessed using intraclass correlation coefficient (ICC) and repeatability/reproducibility coefficients.</p><p><strong>Results: </strong>Intra-reader agreement was good regardless of diameter or reader: all ICC ≥ 0.90, repeatability ranging from ± 0.26 to ± 0.48 cm (CT), ± 0.30 to ± 0.52 cm (BB), and ± 0.29 to ± 0.67 cm (ZTE). The inter-reader agreement was good regardless of sequence: all ICC ≥ 0.88, reproducibility ranging from ± 0.39 to ± 0.42 (OCD), ± 0.26 to ± 0.51 cm (ISD), and ± 0.53 to ± 0.58 cm (MTD). ZTE and BB showed similar agreement with CT: ± 0.57 to ± 0.81 cm when including inter-reader variability; ± 0.34 to ± 0.47 cm for only intra-reader variability.</p><p><strong>Conclusion: </strong>ZTE and BB sequences provided reliable measurements with good agreement with CT, for obstetric pelvimetry. Further validation in the context of pregnancy is needed.</p><p><strong>Relevance statement: </strong>MRI-based pseudo-CT sequences are a promising radiation-free alternative to CT for obstetric pelvimetry, offering the prospect of accurate, reliable measurements of pelvic diameters in pregnant women.</p><p><strong>Trial registration: </strong>The population included female patients with suspected multiple myeloma from a previous prospective oncology trial (ClinicalTrials.gov: NCT05381077).</p><p><strong>Key points: </strong>This study explores pseudo-CT MRI sequences for radiation-free non-invasive obstetric pelvimetry. Pseudo-CT zero echo time and black bone sequences provide repeatable and reproducible measurements of pelvic diameters. Pseudo-CT MRI sequences show good inter-technique agreement with the reference CT.</p>","PeriodicalId":36926,"journal":{"name":"European Radiology Experimental","volume":"9 1","pages":"52"},"PeriodicalIF":3.7000,"publicationDate":"2025-05-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12089014/pdf/","citationCount":"0","resultStr":"{\"title\":\"MRI-based pseudo-CT sequences as a radiation-free alternative to CT for obstetric pelvimetry: a proof-of-concept study.\",\"authors\":\"Caroline Chabot, Mathilde Haegeman, Eya Chaouch, Dana Dumitriu, Renaud Menten, Patricia Steenhaut, Pierre Bernard, Perrine Triqueneaux, Nicolas Michoux, Frédéric E Lecouvet\",\"doi\":\"10.1186/s41747-025-00585-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Pelvimetry is essential in obstetrics for delivery planning. While computed tomography (CT) is the standard, magnetic resonance imaging (MRI) offers a radiation-free alternative with zero echo time (ZTE) and black bone (BB) sequences providing high bone-to-soft tissue contrast within short scan times. This proof-of-concept study evaluates the reliability of these sequences and the agreement with CT for pelvimetry in a predominantly elderly population.</p><p><strong>Methods: </strong>This retrospective study included 21 female patients who underwent 3-T whole-body MRI including ZTE and BB sequences and <sup>18</sup>fluorodeoxyglucose (<sup>18</sup>F-FDG) positron emission tomography (PET)/CT with optimized low-dose whole-body CT. Obstetric conjugate diameter (OCD), interspinous diameter (ISD), and median transverse diameter (MTD) were measured by five radiologists. Intra-reader, inter-reader, and inter-technique agreement were assessed using intraclass correlation coefficient (ICC) and repeatability/reproducibility coefficients.</p><p><strong>Results: </strong>Intra-reader agreement was good regardless of diameter or reader: all ICC ≥ 0.90, repeatability ranging from ± 0.26 to ± 0.48 cm (CT), ± 0.30 to ± 0.52 cm (BB), and ± 0.29 to ± 0.67 cm (ZTE). The inter-reader agreement was good regardless of sequence: all ICC ≥ 0.88, reproducibility ranging from ± 0.39 to ± 0.42 (OCD), ± 0.26 to ± 0.51 cm (ISD), and ± 0.53 to ± 0.58 cm (MTD). ZTE and BB showed similar agreement with CT: ± 0.57 to ± 0.81 cm when including inter-reader variability; ± 0.34 to ± 0.47 cm for only intra-reader variability.</p><p><strong>Conclusion: </strong>ZTE and BB sequences provided reliable measurements with good agreement with CT, for obstetric pelvimetry. Further validation in the context of pregnancy is needed.</p><p><strong>Relevance statement: </strong>MRI-based pseudo-CT sequences are a promising radiation-free alternative to CT for obstetric pelvimetry, offering the prospect of accurate, reliable measurements of pelvic diameters in pregnant women.</p><p><strong>Trial registration: </strong>The population included female patients with suspected multiple myeloma from a previous prospective oncology trial (ClinicalTrials.gov: NCT05381077).</p><p><strong>Key points: </strong>This study explores pseudo-CT MRI sequences for radiation-free non-invasive obstetric pelvimetry. Pseudo-CT zero echo time and black bone sequences provide repeatable and reproducible measurements of pelvic diameters. Pseudo-CT MRI sequences show good inter-technique agreement with the reference CT.</p>\",\"PeriodicalId\":36926,\"journal\":{\"name\":\"European Radiology Experimental\",\"volume\":\"9 1\",\"pages\":\"52\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2025-05-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12089014/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Radiology Experimental\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s41747-025-00585-y\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Radiology Experimental","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s41747-025-00585-y","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

背景:骨盆测量在产科分娩计划中是必不可少的。虽然计算机断层扫描(CT)是标准,但磁共振成像(MRI)提供了零回波时间(中兴通讯)和黑骨(BB)序列的无辐射替代方案,可在短扫描时间内提供高骨-软组织对比度。这项概念验证研究评估了这些序列的可靠性,并与CT在主要老年人群中骨盆测量的一致性。方法:回顾性研究21例女性患者,行3-T全身MRI(包括ZTE和BB序列)和18氟脱氧葡萄糖(18F-FDG)正电子发射断层扫描(PET)/CT,优化低剂量全身CT。产科共轭直径(OCD)、棘间直径(ISD)和中位横径(MTD)由5名放射科医生测量。使用类内相关系数(ICC)和可重复性/再现性系数评估阅读器内、阅读器间和技术间的一致性。结果:无论直径或读取器,读取器内一致性良好:所有ICC≥0.90,重复性范围为±0.26至±0.48 cm (CT),±0.30至±0.52 cm (BB)和±0.29至±0.67 cm(中兴)。无论序列如何,阅读器间一致性良好:所有ICC≥0.88,重现性范围为±0.39至±0.42 (OCD),±0.26至±0.51 cm (ISD)和±0.53至±0.58 cm (MTD)。中兴通讯和BB显示出与CT相似的一致性:当包括阅读器间变异时,±0.57至±0.81 cm;±0.34至±0.47 cm仅为读取器内变异。结论:中兴和BB序列为产科骨盆测量提供了可靠的测量结果,与CT吻合良好。需要在妊娠背景下进一步验证。相关声明:基于mri的伪CT序列是一种很有前途的无辐射产科骨盆测量替代CT,为孕妇骨盆直径的准确、可靠测量提供了前景。试验注册:人群包括先前前瞻性肿瘤试验(ClinicalTrials.gov: NCT05381077)中疑似多发性骨髓瘤的女性患者。本研究探讨了伪ct MRI序列在无辐射无创产科骨盆测量中的应用。伪ct零回声时间和黑骨序列提供可重复和可再现的骨盆直径测量。伪CT MRI序列显示与参考CT具有良好的技术一致性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
MRI-based pseudo-CT sequences as a radiation-free alternative to CT for obstetric pelvimetry: a proof-of-concept study.

Background: Pelvimetry is essential in obstetrics for delivery planning. While computed tomography (CT) is the standard, magnetic resonance imaging (MRI) offers a radiation-free alternative with zero echo time (ZTE) and black bone (BB) sequences providing high bone-to-soft tissue contrast within short scan times. This proof-of-concept study evaluates the reliability of these sequences and the agreement with CT for pelvimetry in a predominantly elderly population.

Methods: This retrospective study included 21 female patients who underwent 3-T whole-body MRI including ZTE and BB sequences and 18fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/CT with optimized low-dose whole-body CT. Obstetric conjugate diameter (OCD), interspinous diameter (ISD), and median transverse diameter (MTD) were measured by five radiologists. Intra-reader, inter-reader, and inter-technique agreement were assessed using intraclass correlation coefficient (ICC) and repeatability/reproducibility coefficients.

Results: Intra-reader agreement was good regardless of diameter or reader: all ICC ≥ 0.90, repeatability ranging from ± 0.26 to ± 0.48 cm (CT), ± 0.30 to ± 0.52 cm (BB), and ± 0.29 to ± 0.67 cm (ZTE). The inter-reader agreement was good regardless of sequence: all ICC ≥ 0.88, reproducibility ranging from ± 0.39 to ± 0.42 (OCD), ± 0.26 to ± 0.51 cm (ISD), and ± 0.53 to ± 0.58 cm (MTD). ZTE and BB showed similar agreement with CT: ± 0.57 to ± 0.81 cm when including inter-reader variability; ± 0.34 to ± 0.47 cm for only intra-reader variability.

Conclusion: ZTE and BB sequences provided reliable measurements with good agreement with CT, for obstetric pelvimetry. Further validation in the context of pregnancy is needed.

Relevance statement: MRI-based pseudo-CT sequences are a promising radiation-free alternative to CT for obstetric pelvimetry, offering the prospect of accurate, reliable measurements of pelvic diameters in pregnant women.

Trial registration: The population included female patients with suspected multiple myeloma from a previous prospective oncology trial (ClinicalTrials.gov: NCT05381077).

Key points: This study explores pseudo-CT MRI sequences for radiation-free non-invasive obstetric pelvimetry. Pseudo-CT zero echo time and black bone sequences provide repeatable and reproducible measurements of pelvic diameters. Pseudo-CT MRI sequences show good inter-technique agreement with the reference CT.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Radiology Experimental
European Radiology Experimental Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
6.70
自引率
2.60%
发文量
56
审稿时长
18 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信