{"title":"ZIF-67硫化Co3S4中空多面体对氟喹诺酮类药物的吸附及其在HPLC-UV前分散固相萃取中的应用","authors":"Youfang Qi, Xueping Dang, Huaixia Chen","doi":"10.1016/j.aca.2025.344211","DOIUrl":null,"url":null,"abstract":"<h3>Background</h3>Developing pretreatment technique with new adsorbent is essential to improve the detection sensitivity of trace fluoroquinolones (FQs) in complex sample. Zeolite imidazole skeleton-67 (ZIF-67) has adsorbability for FQs, but its structure of rhombohedral dodecahedra may reduce the efficiency of mass transfer, and its application is limited by the instability and poor recyclability.<h3>Results</h3>A S-doped hollow Co<sub>3</sub>S<sub>4</sub> polyhedron was prepared by sulfidation of ZIF-67 with thioacetamide and applied for disperse solid phase extraction (DSPE) of four FQs. SEM and TEM confirmed its hollow structure, the BET specific surface area was 40.17 m<sup>2</sup>/g and the maximum adsorption capacity was up to 53.42 mg/g. The adsorption kinetics and isotherm of FQs on the Co<sub>3</sub>S<sub>4</sub> polyhedron were investigated. The adsorption process was a chemisorption reaction, which depends on electrostatic interaction, surface complexation, π-π interaction and hydrogen bonding. A DSPE-HPLC-UV method based on the hollow Co<sub>3</sub>S<sub>4</sub> polyhedron was developed to determine trace FQs. The method has broad linear range with LODs of 0.10 - 0.15 μg/kg and LOQs of 0.30 - 0.50 μg/kg. The intra-batch and inter-batch RSDs were less than 10%. The recovery rate of FQs in honey samples was satisfactory.<h3>Significance</h3>The hollow Co<sub>3</sub>S<sub>4</sub> polyhedron has high extraction efficiency for FQs because of the large cavities. Its maximum adsorption capacity was higher than some adsorbents and about 2 - 3 times than ZIF-67. It has better stability and repeatability. The DSPE-HPLC-UV method based on the hollow Co<sub>3</sub>S<sub>4</sub> polyhedron has high sensitivity and is dependable for the determination of trace FQs in complex sample.","PeriodicalId":240,"journal":{"name":"Analytica Chimica Acta","volume":"121 1","pages":"344211"},"PeriodicalIF":5.7000,"publicationDate":"2025-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Adsorption of fluoroquinolones on hollow Co3S4 polyhedron sulfidated from ZIF-67 and its application of dispersed solid phase extraction prior to HPLC-UV\",\"authors\":\"Youfang Qi, Xueping Dang, Huaixia Chen\",\"doi\":\"10.1016/j.aca.2025.344211\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<h3>Background</h3>Developing pretreatment technique with new adsorbent is essential to improve the detection sensitivity of trace fluoroquinolones (FQs) in complex sample. Zeolite imidazole skeleton-67 (ZIF-67) has adsorbability for FQs, but its structure of rhombohedral dodecahedra may reduce the efficiency of mass transfer, and its application is limited by the instability and poor recyclability.<h3>Results</h3>A S-doped hollow Co<sub>3</sub>S<sub>4</sub> polyhedron was prepared by sulfidation of ZIF-67 with thioacetamide and applied for disperse solid phase extraction (DSPE) of four FQs. SEM and TEM confirmed its hollow structure, the BET specific surface area was 40.17 m<sup>2</sup>/g and the maximum adsorption capacity was up to 53.42 mg/g. The adsorption kinetics and isotherm of FQs on the Co<sub>3</sub>S<sub>4</sub> polyhedron were investigated. The adsorption process was a chemisorption reaction, which depends on electrostatic interaction, surface complexation, π-π interaction and hydrogen bonding. A DSPE-HPLC-UV method based on the hollow Co<sub>3</sub>S<sub>4</sub> polyhedron was developed to determine trace FQs. The method has broad linear range with LODs of 0.10 - 0.15 μg/kg and LOQs of 0.30 - 0.50 μg/kg. The intra-batch and inter-batch RSDs were less than 10%. The recovery rate of FQs in honey samples was satisfactory.<h3>Significance</h3>The hollow Co<sub>3</sub>S<sub>4</sub> polyhedron has high extraction efficiency for FQs because of the large cavities. Its maximum adsorption capacity was higher than some adsorbents and about 2 - 3 times than ZIF-67. It has better stability and repeatability. The DSPE-HPLC-UV method based on the hollow Co<sub>3</sub>S<sub>4</sub> polyhedron has high sensitivity and is dependable for the determination of trace FQs in complex sample.\",\"PeriodicalId\":240,\"journal\":{\"name\":\"Analytica Chimica Acta\",\"volume\":\"121 1\",\"pages\":\"344211\"},\"PeriodicalIF\":5.7000,\"publicationDate\":\"2025-05-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytica Chimica Acta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1016/j.aca.2025.344211\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytica Chimica Acta","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1016/j.aca.2025.344211","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

背景开发新型吸附剂预处理技术是提高复杂样品中痕量氟喹诺酮类药物检测灵敏度的重要手段。沸石咪唑骨架-67 (ZIF-67)对FQs具有吸附性,但其菱形十二面体结构可能降低传质效率,不稳定性和可回收性差限制了其应用。结果用硫代乙酰胺对ZIF-67进行磺化,制备了sa掺杂Co3S4中空多面体,并应用于4种FQs的分散固相萃取(DSPE)。SEM和TEM证实了其中空结构,BET比表面积为40.17 m2/g,最大吸附容量为53.42 mg/g。研究了FQs在Co3S4多面体上的吸附动力学和等温线。吸附过程为化学吸附反应,主要依赖于静电相互作用、表面络合作用、π-π相互作用和氢键作用。建立了以空心Co3S4多面体为底物的DSPE-HPLC-UV法测定痕量FQs。该方法线性范围宽,检出限为0.10 ~ 0.15 μg/kg,检出限为0.30 ~ 0.50 μg/kg。批内、批间rsd均小于10%。FQs在蜂蜜样品中的回收率令人满意。意义空心Co3S4多面体由于空腔大,对FQs的提取效率高。其最大吸附量高于部分吸附剂,约为ZIF-67的2 ~ 3倍。具有较好的稳定性和重复性。基于空心Co3S4多面体的DSPE-HPLC-UV方法灵敏度高,可用于复杂样品中痕量FQs的测定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Adsorption of fluoroquinolones on hollow Co3S4 polyhedron sulfidated from ZIF-67 and its application of dispersed solid phase extraction prior to HPLC-UV

Adsorption of fluoroquinolones on hollow Co3S4 polyhedron sulfidated from ZIF-67 and its application of dispersed solid phase extraction prior to HPLC-UV

Background

Developing pretreatment technique with new adsorbent is essential to improve the detection sensitivity of trace fluoroquinolones (FQs) in complex sample. Zeolite imidazole skeleton-67 (ZIF-67) has adsorbability for FQs, but its structure of rhombohedral dodecahedra may reduce the efficiency of mass transfer, and its application is limited by the instability and poor recyclability.

Results

A S-doped hollow Co3S4 polyhedron was prepared by sulfidation of ZIF-67 with thioacetamide and applied for disperse solid phase extraction (DSPE) of four FQs. SEM and TEM confirmed its hollow structure, the BET specific surface area was 40.17 m2/g and the maximum adsorption capacity was up to 53.42 mg/g. The adsorption kinetics and isotherm of FQs on the Co3S4 polyhedron were investigated. The adsorption process was a chemisorption reaction, which depends on electrostatic interaction, surface complexation, π-π interaction and hydrogen bonding. A DSPE-HPLC-UV method based on the hollow Co3S4 polyhedron was developed to determine trace FQs. The method has broad linear range with LODs of 0.10 - 0.15 μg/kg and LOQs of 0.30 - 0.50 μg/kg. The intra-batch and inter-batch RSDs were less than 10%. The recovery rate of FQs in honey samples was satisfactory.

Significance

The hollow Co3S4 polyhedron has high extraction efficiency for FQs because of the large cavities. Its maximum adsorption capacity was higher than some adsorbents and about 2 - 3 times than ZIF-67. It has better stability and repeatability. The DSPE-HPLC-UV method based on the hollow Co3S4 polyhedron has high sensitivity and is dependable for the determination of trace FQs in complex sample.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analytica Chimica Acta
Analytica Chimica Acta 化学-分析化学
CiteScore
10.40
自引率
6.50%
发文量
1081
审稿时长
38 days
期刊介绍: Analytica Chimica Acta has an open access mirror journal Analytica Chimica Acta: X, sharing the same aims and scope, editorial team, submission system and rigorous peer review. Analytica Chimica Acta provides a forum for the rapid publication of original research, and critical, comprehensive reviews dealing with all aspects of fundamental and applied modern analytical chemistry. The journal welcomes the submission of research papers which report studies concerning the development of new and significant analytical methodologies. In determining the suitability of submitted articles for publication, particular scrutiny will be placed on the degree of novelty and impact of the research and the extent to which it adds to the existing body of knowledge in analytical chemistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信