由本地ASIC电子器件实现的具有方位平面波和行复用仰角波束形成的手持大型2D阵列。

IF 3 2区 工程技术 Q1 ACOUSTICS
Robert Wodnicki, Josquin Foiret, Baoqiang Liu, Ning Lu, Xin Sun, Junhang Zhang, Haochen Kang, Lei Fu, Christophe Notard, Mathieu Legros, Chifeng Chang, Jesse T Yen, Qifa Zhou, Katherine W Ferrara
{"title":"由本地ASIC电子器件实现的具有方位平面波和行复用仰角波束形成的手持大型2D阵列。","authors":"Robert Wodnicki, Josquin Foiret, Baoqiang Liu, Ning Lu, Xin Sun, Junhang Zhang, Haochen Kang, Lei Fu, Christophe Notard, Mathieu Legros, Chifeng Chang, Jesse T Yen, Qifa Zhou, Katherine W Ferrara","doi":"10.1109/TUFFC.2025.3570732","DOIUrl":null,"url":null,"abstract":"<p><p>Large aperture 2D arrays benefit from improved lateral resolution at depth, due to the dependence of beamwidth on the inverse of the aperture width, and improved contrast resolution due to electronic focusing. We have been developing modular large aperture multi-row 1,024 (64 azimuth × 16 elevation) element, 2D arrays based on custom-designed and locally integrated Application Specific Integrated Circuit (ASIC) multiplexing devices. The implemented handheld large array prototype probe for human imaging consists of multiple rows with multiplexed synthetic aperture in elevation and planewave transmits in azimuth. The pitch of the acoustic array is 650 μm in azimuth by 1,000 μm in elevation, with a 2.4 MHz (FBW=88%) center frequency and total active aperture of 42 mm × 16 mm. We interfaced the large aperture array and multiplexing ASICs, along with local preamplifier devices for improved sensitivity, and a local FPGA for digital ASIC control, to a configurable ultrasound imaging platform and demonstrate 2D orthogonal and full 3D-beamformed imaging. The implemented imaging prototype includes local buffering for improved sensitivity of the high impedance 2D array elements, and realizes penetration down to 140 mm, experimental lateral/axial resolution at 67 mm of 1.1 mm/0.4 mm, and maximum experimental CNR of 2.1 for 8 mm cylindrical cysts, and 1.7 for 10 mm spherical cysts. We demonstrate in-vivo imaging of liver in human volunteers utilizing a hermetically-sealed and safety-validated handheld prototype of the large 2D array. Preliminary results are promising for clinical imaging in future studies.</p>","PeriodicalId":13322,"journal":{"name":"IEEE transactions on ultrasonics, ferroelectrics, and frequency control","volume":"PP ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Handheld Large 2D Array with Azimuthal Planewave and Row-Multiplexed Elevation Beamforming Enabled by local ASIC Electronics.\",\"authors\":\"Robert Wodnicki, Josquin Foiret, Baoqiang Liu, Ning Lu, Xin Sun, Junhang Zhang, Haochen Kang, Lei Fu, Christophe Notard, Mathieu Legros, Chifeng Chang, Jesse T Yen, Qifa Zhou, Katherine W Ferrara\",\"doi\":\"10.1109/TUFFC.2025.3570732\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Large aperture 2D arrays benefit from improved lateral resolution at depth, due to the dependence of beamwidth on the inverse of the aperture width, and improved contrast resolution due to electronic focusing. We have been developing modular large aperture multi-row 1,024 (64 azimuth × 16 elevation) element, 2D arrays based on custom-designed and locally integrated Application Specific Integrated Circuit (ASIC) multiplexing devices. The implemented handheld large array prototype probe for human imaging consists of multiple rows with multiplexed synthetic aperture in elevation and planewave transmits in azimuth. The pitch of the acoustic array is 650 μm in azimuth by 1,000 μm in elevation, with a 2.4 MHz (FBW=88%) center frequency and total active aperture of 42 mm × 16 mm. We interfaced the large aperture array and multiplexing ASICs, along with local preamplifier devices for improved sensitivity, and a local FPGA for digital ASIC control, to a configurable ultrasound imaging platform and demonstrate 2D orthogonal and full 3D-beamformed imaging. The implemented imaging prototype includes local buffering for improved sensitivity of the high impedance 2D array elements, and realizes penetration down to 140 mm, experimental lateral/axial resolution at 67 mm of 1.1 mm/0.4 mm, and maximum experimental CNR of 2.1 for 8 mm cylindrical cysts, and 1.7 for 10 mm spherical cysts. We demonstrate in-vivo imaging of liver in human volunteers utilizing a hermetically-sealed and safety-validated handheld prototype of the large 2D array. Preliminary results are promising for clinical imaging in future studies.</p>\",\"PeriodicalId\":13322,\"journal\":{\"name\":\"IEEE transactions on ultrasonics, ferroelectrics, and frequency control\",\"volume\":\"PP \",\"pages\":\"\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE transactions on ultrasonics, ferroelectrics, and frequency control\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1109/TUFFC.2025.3570732\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on ultrasonics, ferroelectrics, and frequency control","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1109/TUFFC.2025.3570732","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

摘要

由于波束宽度依赖于孔径宽度的倒数,大孔径二维阵列得益于深度横向分辨率的提高,以及电子聚焦带来的对比度分辨率的提高。我们一直在开发模块化大孔径多排1024(64方位角× 16仰角)元件,基于定制设计和本地集成应用专用集成电路(ASIC)多路复用器件的2D阵列。所实现的手持式人体成像大阵列原型探头由多排高程多路合成孔径和方位角平面波传输组成。声阵的间距为方位角650 μm,仰角1000 μm,中心频率为2.4 MHz (FBW=88%),总有效孔径为42 mm × 16 mm。我们将大孔径阵列和多路复用ASIC,以及用于提高灵敏度的本地前置放大器设备和用于数字ASIC控制的本地FPGA连接到可配置的超声成像平台,并演示了2D正交和全3d波束形成成像。所实现的成像原型包括局部缓冲,以提高高阻抗二维阵列元件的灵敏度,并实现了低至140 mm的穿透,67 mm的实验横向/轴向分辨率为1.1 mm/0.4 mm, 8 mm圆柱形囊肿的最大实验CNR为2.1,10 mm球形囊肿的最大实验CNR为1.7。我们展示了人类志愿者肝脏的体内成像,利用密封和安全验证的手持大型2D阵列原型。初步结果对今后的临床影像学研究具有一定的指导意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Handheld Large 2D Array with Azimuthal Planewave and Row-Multiplexed Elevation Beamforming Enabled by local ASIC Electronics.

Large aperture 2D arrays benefit from improved lateral resolution at depth, due to the dependence of beamwidth on the inverse of the aperture width, and improved contrast resolution due to electronic focusing. We have been developing modular large aperture multi-row 1,024 (64 azimuth × 16 elevation) element, 2D arrays based on custom-designed and locally integrated Application Specific Integrated Circuit (ASIC) multiplexing devices. The implemented handheld large array prototype probe for human imaging consists of multiple rows with multiplexed synthetic aperture in elevation and planewave transmits in azimuth. The pitch of the acoustic array is 650 μm in azimuth by 1,000 μm in elevation, with a 2.4 MHz (FBW=88%) center frequency and total active aperture of 42 mm × 16 mm. We interfaced the large aperture array and multiplexing ASICs, along with local preamplifier devices for improved sensitivity, and a local FPGA for digital ASIC control, to a configurable ultrasound imaging platform and demonstrate 2D orthogonal and full 3D-beamformed imaging. The implemented imaging prototype includes local buffering for improved sensitivity of the high impedance 2D array elements, and realizes penetration down to 140 mm, experimental lateral/axial resolution at 67 mm of 1.1 mm/0.4 mm, and maximum experimental CNR of 2.1 for 8 mm cylindrical cysts, and 1.7 for 10 mm spherical cysts. We demonstrate in-vivo imaging of liver in human volunteers utilizing a hermetically-sealed and safety-validated handheld prototype of the large 2D array. Preliminary results are promising for clinical imaging in future studies.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.70
自引率
16.70%
发文量
583
审稿时长
4.5 months
期刊介绍: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control includes the theory, technology, materials, and applications relating to: (1) the generation, transmission, and detection of ultrasonic waves and related phenomena; (2) medical ultrasound, including hyperthermia, bioeffects, tissue characterization and imaging; (3) ferroelectric, piezoelectric, and piezomagnetic materials, including crystals, polycrystalline solids, films, polymers, and composites; (4) frequency control, timing and time distribution, including crystal oscillators and other means of classical frequency control, and atomic, molecular and laser frequency control standards. Areas of interest range from fundamental studies to the design and/or applications of devices and systems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信