用绝对线性偏差法评估常规和数字全弓印模的可行性:体外研究。

IF 2.6 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Jianhua Ji, Luming Wei, Xuzhe Zha, Huiying Guo, Penglai Wang
{"title":"用绝对线性偏差法评估常规和数字全弓印模的可行性:体外研究。","authors":"Jianhua Ji, Luming Wei, Xuzhe Zha, Huiying Guo, Penglai Wang","doi":"10.1186/s12903-025-06068-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Intraoral scanners (IOS) facilitate dental treatment, but the efficacy in full-arch scanning remains controversial. The aim of this study was to compare arch deformations between conventional impressions (CIs) and digital impressions (DIs) across six distinct spans in the maxillary and mandibular models, using the absolute linear deviation method.</p><p><strong>Methods: </strong>Standard maxillary and mandibular models, each with seven cylindrical landmarks added, were used as the reference. CIs and DIs as test scans (n = 15 each) were performed on the models using silicone impression material and three IOSs: CS3600, Trios3, and Trios5. The trueness of the distances and angles between the remaining cylinders and initial scanning cylinder were evaluated. Data were analyzed using the Kruskal-Wallis and One-way ANOVA tests, with the Bonferroni test for post hoc analysis (α = 0.05).</p><p><strong>Results: </strong>Deviations of DIs increased gradually from smaller spans to full-arch spans, while deviations of CIs remained stable. Within a 5-tooth-units, DIs provided superior trueness compared to CIs (P < 0.05), except for ΔL8, where the results from four impression methods were comparable (P = 0.28). For other measurements, CIs exhibited significantly better trueness than three IOSs (P < 0.05).</p><p><strong>Conclusions: </strong>The current accuracy of IOSs was insufficient for full-arch applications, but suitable for short scan ranges (fixed prostheses within a 5-unit span).</p>","PeriodicalId":9072,"journal":{"name":"BMC Oral Health","volume":"25 1","pages":"720"},"PeriodicalIF":2.6000,"publicationDate":"2025-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12079954/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluating the feasibility of conventional and digital impressions of full-arch by the absolute linear deviation method: an in vitro study.\",\"authors\":\"Jianhua Ji, Luming Wei, Xuzhe Zha, Huiying Guo, Penglai Wang\",\"doi\":\"10.1186/s12903-025-06068-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Intraoral scanners (IOS) facilitate dental treatment, but the efficacy in full-arch scanning remains controversial. The aim of this study was to compare arch deformations between conventional impressions (CIs) and digital impressions (DIs) across six distinct spans in the maxillary and mandibular models, using the absolute linear deviation method.</p><p><strong>Methods: </strong>Standard maxillary and mandibular models, each with seven cylindrical landmarks added, were used as the reference. CIs and DIs as test scans (n = 15 each) were performed on the models using silicone impression material and three IOSs: CS3600, Trios3, and Trios5. The trueness of the distances and angles between the remaining cylinders and initial scanning cylinder were evaluated. Data were analyzed using the Kruskal-Wallis and One-way ANOVA tests, with the Bonferroni test for post hoc analysis (α = 0.05).</p><p><strong>Results: </strong>Deviations of DIs increased gradually from smaller spans to full-arch spans, while deviations of CIs remained stable. Within a 5-tooth-units, DIs provided superior trueness compared to CIs (P < 0.05), except for ΔL8, where the results from four impression methods were comparable (P = 0.28). For other measurements, CIs exhibited significantly better trueness than three IOSs (P < 0.05).</p><p><strong>Conclusions: </strong>The current accuracy of IOSs was insufficient for full-arch applications, but suitable for short scan ranges (fixed prostheses within a 5-unit span).</p>\",\"PeriodicalId\":9072,\"journal\":{\"name\":\"BMC Oral Health\",\"volume\":\"25 1\",\"pages\":\"720\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2025-05-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12079954/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BMC Oral Health\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12903-025-06068-1\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Oral Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12903-025-06068-1","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

背景:口腔内扫描仪(IOS)促进牙科治疗,但在全弓扫描的有效性仍然存在争议。本研究的目的是使用绝对线性偏差法,比较上颌和下颌骨模型中六个不同牙槽的传统印模(CIs)和数字印模(DIs)的弓变形。方法:以标准上颌和下颌骨模型为参照,各增加7个圆柱形标志。使用硅胶印模材料和三种IOSs (CS3600、Trios3和Trios5)对模型进行ci和DIs测试扫描(n = 15)。评估了剩余圆柱与初始扫描圆柱之间距离和角度的准确性。数据分析采用Kruskal-Wallis检验和单因素方差分析,事后分析采用Bonferroni检验(α = 0.05)。结果:DIs的偏差从小跨到全跨逐渐增大,而CIs的偏差保持稳定。在5个牙单元内,与CIs相比,DIs提供了更好的正确率(P结论:目前的iss精度不足以用于全弓应用,但适用于短扫描范围(5个牙单元范围内的固定假体)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluating the feasibility of conventional and digital impressions of full-arch by the absolute linear deviation method: an in vitro study.

Background: Intraoral scanners (IOS) facilitate dental treatment, but the efficacy in full-arch scanning remains controversial. The aim of this study was to compare arch deformations between conventional impressions (CIs) and digital impressions (DIs) across six distinct spans in the maxillary and mandibular models, using the absolute linear deviation method.

Methods: Standard maxillary and mandibular models, each with seven cylindrical landmarks added, were used as the reference. CIs and DIs as test scans (n = 15 each) were performed on the models using silicone impression material and three IOSs: CS3600, Trios3, and Trios5. The trueness of the distances and angles between the remaining cylinders and initial scanning cylinder were evaluated. Data were analyzed using the Kruskal-Wallis and One-way ANOVA tests, with the Bonferroni test for post hoc analysis (α = 0.05).

Results: Deviations of DIs increased gradually from smaller spans to full-arch spans, while deviations of CIs remained stable. Within a 5-tooth-units, DIs provided superior trueness compared to CIs (P < 0.05), except for ΔL8, where the results from four impression methods were comparable (P = 0.28). For other measurements, CIs exhibited significantly better trueness than three IOSs (P < 0.05).

Conclusions: The current accuracy of IOSs was insufficient for full-arch applications, but suitable for short scan ranges (fixed prostheses within a 5-unit span).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
BMC Oral Health
BMC Oral Health DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.90
自引率
6.90%
发文量
481
审稿时长
6-12 weeks
期刊介绍: BMC Oral Health is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of disorders of the mouth, teeth and gums, as well as related molecular genetics, pathophysiology, and epidemiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信