{"title":"辐照4H-SiC MESFET的位移损伤","authors":"Steven C. Witczak;Wayne A. Martin;James W. Palko;Joseph R. Srour;Rokutaro Koga","doi":"10.1109/TNS.2025.3550298","DOIUrl":null,"url":null,"abstract":"Radiation-induced degradation of a commercial 4H-SiC metal-semiconductor field-effect transistor (MESFET) is examined following exposure to 941-MeV Bi ions, 20-MeV protons and 60Co <inline-formula> <tex-math>$\\gamma $ </tex-math></inline-formula>-rays. The degradation results primarily from displacement damage. The device is radiation-hard to an equivalent 1-MeV neutron fluence of <inline-formula> <tex-math>$2.6\\times 10^{14}$ </tex-math></inline-formula> cm−2. The relative contributions of carrier removal and mobility degradation to device degradation are comparable. The channel mobility is reduced by 40% at a non-ionizing dose (NID) of <inline-formula> <tex-math>$3.1\\times 10^{12}$ </tex-math></inline-formula> MeV/g. The carrier removal rate normalized to 1-MeV neutron fluence is <inline-formula> <tex-math>$32~\\pm ~3$ </tex-math></inline-formula> cm−1, which is more than six times the rates reported for similar 6H-SiC devices. The difference in carrier removal rates for the two polytypes is apparently related to differences in radiation defect properties. The degradation scales with elastic non-ionizing energy loss (NIEL), which suggests that nuclear inelastic interactions, which tend to produce long recoils relative to the device channel depth, do not contribute to parametric degradation. This implies that qualification testing of certain device types with high-energy protons directed at the device surface may lead to an overestimation of device lifetime in space.","PeriodicalId":13406,"journal":{"name":"IEEE Transactions on Nuclear Science","volume":"72 5","pages":"1755-1762"},"PeriodicalIF":1.9000,"publicationDate":"2025-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Displacement Damage in an Irradiated 4H-SiC MESFET\",\"authors\":\"Steven C. Witczak;Wayne A. Martin;James W. Palko;Joseph R. Srour;Rokutaro Koga\",\"doi\":\"10.1109/TNS.2025.3550298\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Radiation-induced degradation of a commercial 4H-SiC metal-semiconductor field-effect transistor (MESFET) is examined following exposure to 941-MeV Bi ions, 20-MeV protons and 60Co <inline-formula> <tex-math>$\\\\gamma $ </tex-math></inline-formula>-rays. The degradation results primarily from displacement damage. The device is radiation-hard to an equivalent 1-MeV neutron fluence of <inline-formula> <tex-math>$2.6\\\\times 10^{14}$ </tex-math></inline-formula> cm−2. The relative contributions of carrier removal and mobility degradation to device degradation are comparable. The channel mobility is reduced by 40% at a non-ionizing dose (NID) of <inline-formula> <tex-math>$3.1\\\\times 10^{12}$ </tex-math></inline-formula> MeV/g. The carrier removal rate normalized to 1-MeV neutron fluence is <inline-formula> <tex-math>$32~\\\\pm ~3$ </tex-math></inline-formula> cm−1, which is more than six times the rates reported for similar 6H-SiC devices. The difference in carrier removal rates for the two polytypes is apparently related to differences in radiation defect properties. The degradation scales with elastic non-ionizing energy loss (NIEL), which suggests that nuclear inelastic interactions, which tend to produce long recoils relative to the device channel depth, do not contribute to parametric degradation. This implies that qualification testing of certain device types with high-energy protons directed at the device surface may lead to an overestimation of device lifetime in space.\",\"PeriodicalId\":13406,\"journal\":{\"name\":\"IEEE Transactions on Nuclear Science\",\"volume\":\"72 5\",\"pages\":\"1755-1762\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2025-03-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Nuclear Science\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10922199/\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Nuclear Science","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10922199/","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

研究了商用4H-SiC金属半导体场效应晶体管(MESFET)在暴露于941 mev Bi离子、20 mev质子和60Co γ射线后的辐射诱导降解。退化的主要原因是位移损伤。该装置的辐射强度相当于1兆电子伏的中子通量为2.6\ × 10^{14}$ cm−2。载波去除和迁移率退化对设备退化的相对贡献是可比的。当非电离剂量(NID)为3.1\ × 10^{12}$ MeV/g时,通道迁移率降低了40%。以1 mev中子通量归一化的载流子去除率为$32~\pm ~ $3 $ cm−1,是同类6H-SiC器件的6倍以上。两种多型的载流子去除率的差异显然与辐射缺陷特性的差异有关。退化尺度与弹性非电离能量损失(NIEL)有关,这表明核非弹性相互作用倾向于产生相对于器件通道深度的较长反冲,但对参数退化没有贡献。这意味着对某些类型的器件进行高能质子指向器件表面的鉴定测试可能会导致对器件在空间中的寿命的高估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Displacement Damage in an Irradiated 4H-SiC MESFET
Radiation-induced degradation of a commercial 4H-SiC metal-semiconductor field-effect transistor (MESFET) is examined following exposure to 941-MeV Bi ions, 20-MeV protons and 60Co $\gamma $ -rays. The degradation results primarily from displacement damage. The device is radiation-hard to an equivalent 1-MeV neutron fluence of $2.6\times 10^{14}$ cm−2. The relative contributions of carrier removal and mobility degradation to device degradation are comparable. The channel mobility is reduced by 40% at a non-ionizing dose (NID) of $3.1\times 10^{12}$ MeV/g. The carrier removal rate normalized to 1-MeV neutron fluence is $32~\pm ~3$ cm−1, which is more than six times the rates reported for similar 6H-SiC devices. The difference in carrier removal rates for the two polytypes is apparently related to differences in radiation defect properties. The degradation scales with elastic non-ionizing energy loss (NIEL), which suggests that nuclear inelastic interactions, which tend to produce long recoils relative to the device channel depth, do not contribute to parametric degradation. This implies that qualification testing of certain device types with high-energy protons directed at the device surface may lead to an overestimation of device lifetime in space.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IEEE Transactions on Nuclear Science
IEEE Transactions on Nuclear Science 工程技术-工程:电子与电气
CiteScore
3.70
自引率
27.80%
发文量
314
审稿时长
6.2 months
期刊介绍: The IEEE Transactions on Nuclear Science is a publication of the IEEE Nuclear and Plasma Sciences Society. It is viewed as the primary source of technical information in many of the areas it covers. As judged by JCR impact factor, TNS consistently ranks in the top five journals in the category of Nuclear Science & Technology. It has one of the higher immediacy indices, indicating that the information it publishes is viewed as timely, and has a relatively long citation half-life, indicating that the published information also is viewed as valuable for a number of years. The IEEE Transactions on Nuclear Science is published bimonthly. Its scope includes all aspects of the theory and application of nuclear science and engineering. It focuses on instrumentation for the detection and measurement of ionizing radiation; particle accelerators and their controls; nuclear medicine and its application; effects of radiation on materials, components, and systems; reactor instrumentation and controls; and measurement of radiation in space.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信