Tl₂LaCl₅:Ce晶体与硅光电倍增管耦合用于紧凑型单光子发射计算机断层扫描系统的表征

IF 1.9 3区 工程技术 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC
I. H. Bang;H. W. Park;A. Khan;J. Jegal;H. J. Kim
{"title":"Tl₂LaCl₅:Ce晶体与硅光电倍增管耦合用于紧凑型单光子发射计算机断层扫描系统的表征","authors":"I. H. Bang;H. W. Park;A. Khan;J. Jegal;H. J. Kim","doi":"10.1109/TNS.2025.3562678","DOIUrl":null,"url":null,"abstract":"The novel Tl2LaCl5:Ce (TLC) crystal scintillator has a high density and effective Z number. Hence, a single-photon emission computed tomography (SPECT) detector equipped with the scintillator has excellent X-ray and <inline-formula> <tex-math>$\\gamma $ </tex-math></inline-formula>-ray detection efficiency and a high light yield (LY). The feasibility of utilizing the TLC crystal coupled with a silicon photomultiplier (SiPM) was investigated for a compact SPECT detector. The TLC crystal (Ø<inline-formula> <tex-math>$8\\times 2$ </tex-math></inline-formula> mm) coupled with a one-channel SiPM (<inline-formula> <tex-math>$6.07\\times 6.07$ </tex-math></inline-formula> mm2) was used. Electrical characteristics of the SiPM were used for optimizing the operating voltage and dynamic range. The <inline-formula> <tex-math>$\\gamma $ </tex-math></inline-formula>-rays’ energy spectra of 133 Ba, 241Am, and 152 Eu were obtained. The SiPM outputs were digitized utilizing a data acquisition (DAQ) system. The breakdown voltage of the SiPM was measured to be 24.8 V. The operating voltage was fixed as 29.8 V by comparing energy resolutions for different operating voltages under 81-keV <inline-formula> <tex-math>$\\gamma $ </tex-math></inline-formula>-ray excitation from a 133Ba radioactive source. The linearity of the SiPM was measured to be within 3.7% for up to 8500 incident photons. Owing to the high LY of the TLC crystal and the dynamic range of SiPM, the best energy resolution of the TLC crystal was achieved to be 8.7% full-width-half-maximum at 121.7-keV <inline-formula> <tex-math>$\\gamma $ </tex-math></inline-formula>-ray at the voltage of 29.8 V. The TLC crystal coupled with SiPM is expected to be utilized for the development of compact SPECT detectors. It can replace conventional photomultiplier detectors and attain a good image quality, comparable to that of a solid-state detector in the SPECT system.","PeriodicalId":13406,"journal":{"name":"IEEE Transactions on Nuclear Science","volume":"72 5","pages":"1828-1832"},"PeriodicalIF":1.9000,"publicationDate":"2025-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Characterization of a Tl₂LaCl₅:Ce Crystal Coupled With a Silicon Photomultiplier for a Compact Single-Photon Emission Computed Tomography System\",\"authors\":\"I. H. Bang;H. W. Park;A. Khan;J. Jegal;H. J. Kim\",\"doi\":\"10.1109/TNS.2025.3562678\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The novel Tl2LaCl5:Ce (TLC) crystal scintillator has a high density and effective Z number. Hence, a single-photon emission computed tomography (SPECT) detector equipped with the scintillator has excellent X-ray and <inline-formula> <tex-math>$\\\\gamma $ </tex-math></inline-formula>-ray detection efficiency and a high light yield (LY). The feasibility of utilizing the TLC crystal coupled with a silicon photomultiplier (SiPM) was investigated for a compact SPECT detector. The TLC crystal (Ø<inline-formula> <tex-math>$8\\\\times 2$ </tex-math></inline-formula> mm) coupled with a one-channel SiPM (<inline-formula> <tex-math>$6.07\\\\times 6.07$ </tex-math></inline-formula> mm2) was used. Electrical characteristics of the SiPM were used for optimizing the operating voltage and dynamic range. The <inline-formula> <tex-math>$\\\\gamma $ </tex-math></inline-formula>-rays’ energy spectra of 133 Ba, 241Am, and 152 Eu were obtained. The SiPM outputs were digitized utilizing a data acquisition (DAQ) system. The breakdown voltage of the SiPM was measured to be 24.8 V. The operating voltage was fixed as 29.8 V by comparing energy resolutions for different operating voltages under 81-keV <inline-formula> <tex-math>$\\\\gamma $ </tex-math></inline-formula>-ray excitation from a 133Ba radioactive source. The linearity of the SiPM was measured to be within 3.7% for up to 8500 incident photons. Owing to the high LY of the TLC crystal and the dynamic range of SiPM, the best energy resolution of the TLC crystal was achieved to be 8.7% full-width-half-maximum at 121.7-keV <inline-formula> <tex-math>$\\\\gamma $ </tex-math></inline-formula>-ray at the voltage of 29.8 V. The TLC crystal coupled with SiPM is expected to be utilized for the development of compact SPECT detectors. It can replace conventional photomultiplier detectors and attain a good image quality, comparable to that of a solid-state detector in the SPECT system.\",\"PeriodicalId\":13406,\"journal\":{\"name\":\"IEEE Transactions on Nuclear Science\",\"volume\":\"72 5\",\"pages\":\"1828-1832\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2025-04-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Nuclear Science\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10971417/\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Nuclear Science","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10971417/","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

新型Tl2LaCl5:Ce (TLC)晶体闪烁体具有较高的密度和有效Z数。因此,配备该闪烁体的单光子发射计算机断层扫描(SPECT)探测器具有优异的x射线和γ射线探测效率和高光产率(LY)。研究了薄层色谱晶体与硅光电倍增管(SiPM)耦合用于小型SPECT探测器的可行性。TLC晶体(Ø $8\times 2$ mm)与单通道SiPM ($6.07\times 6.07$ mm2)耦合使用。利用SiPM的电特性优化工作电压和动态范围。得到了133ba、241Am和152eu的γ射线能谱。SiPM输出利用数据采集(DAQ)系统进行数字化。SiPM的击穿电压为24.8 V。通过比较133Ba辐射源81 kev γ射线激发下不同工作电压下的能量分辨率,确定工作电压为29.8 V。当入射光子达到8500个时,SiPM的线性度在3.7%以内。由于TLC晶体的高LY和SiPM的动态范围,在121.7 kev γ射线下,在29.8 V电压下,TLC晶体的能量分辨率达到了8.7%的全宽半最大值。TLC晶体与SiPM相结合有望用于开发紧凑型SPECT探测器。它可以取代传统的光电倍增管探测器,并获得良好的图像质量,可与SPECT系统中的固态探测器相媲美。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Characterization of a Tl₂LaCl₅:Ce Crystal Coupled With a Silicon Photomultiplier for a Compact Single-Photon Emission Computed Tomography System
The novel Tl2LaCl5:Ce (TLC) crystal scintillator has a high density and effective Z number. Hence, a single-photon emission computed tomography (SPECT) detector equipped with the scintillator has excellent X-ray and $\gamma $ -ray detection efficiency and a high light yield (LY). The feasibility of utilizing the TLC crystal coupled with a silicon photomultiplier (SiPM) was investigated for a compact SPECT detector. The TLC crystal (Ø $8\times 2$ mm) coupled with a one-channel SiPM ( $6.07\times 6.07$ mm2) was used. Electrical characteristics of the SiPM were used for optimizing the operating voltage and dynamic range. The $\gamma $ -rays’ energy spectra of 133 Ba, 241Am, and 152 Eu were obtained. The SiPM outputs were digitized utilizing a data acquisition (DAQ) system. The breakdown voltage of the SiPM was measured to be 24.8 V. The operating voltage was fixed as 29.8 V by comparing energy resolutions for different operating voltages under 81-keV $\gamma $ -ray excitation from a 133Ba radioactive source. The linearity of the SiPM was measured to be within 3.7% for up to 8500 incident photons. Owing to the high LY of the TLC crystal and the dynamic range of SiPM, the best energy resolution of the TLC crystal was achieved to be 8.7% full-width-half-maximum at 121.7-keV $\gamma $ -ray at the voltage of 29.8 V. The TLC crystal coupled with SiPM is expected to be utilized for the development of compact SPECT detectors. It can replace conventional photomultiplier detectors and attain a good image quality, comparable to that of a solid-state detector in the SPECT system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IEEE Transactions on Nuclear Science
IEEE Transactions on Nuclear Science 工程技术-工程:电子与电气
CiteScore
3.70
自引率
27.80%
发文量
314
审稿时长
6.2 months
期刊介绍: The IEEE Transactions on Nuclear Science is a publication of the IEEE Nuclear and Plasma Sciences Society. It is viewed as the primary source of technical information in many of the areas it covers. As judged by JCR impact factor, TNS consistently ranks in the top five journals in the category of Nuclear Science & Technology. It has one of the higher immediacy indices, indicating that the information it publishes is viewed as timely, and has a relatively long citation half-life, indicating that the published information also is viewed as valuable for a number of years. The IEEE Transactions on Nuclear Science is published bimonthly. Its scope includes all aspects of the theory and application of nuclear science and engineering. It focuses on instrumentation for the detection and measurement of ionizing radiation; particle accelerators and their controls; nuclear medicine and its application; effects of radiation on materials, components, and systems; reactor instrumentation and controls; and measurement of radiation in space.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信