高凝血活性和低凝血活性样品中阿加曲班对多种APTT试剂影响的变异性。

IF 2.3 4区 医学 Q3 HEMATOLOGY
Osamu Kumano, Masahiro Ieko, Teruto Hashiguchi, Takashi Ito, Satoshi Yamazaki, Sumiyoshi Naito, Masako Yamazaki
{"title":"高凝血活性和低凝血活性样品中阿加曲班对多种APTT试剂影响的变异性。","authors":"Osamu Kumano,&nbsp;Masahiro Ieko,&nbsp;Teruto Hashiguchi,&nbsp;Takashi Ito,&nbsp;Satoshi Yamazaki,&nbsp;Sumiyoshi Naito,&nbsp;Masako Yamazaki","doi":"10.1111/ijlh.14488","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Introduction</h3>\n \n <p>Argatroban is routinely monitored using activated partial thromboplastin time (APTT), with a recommended target range of 1.5–3.0 times. Although this range was established based on clinical trial data, including several APTT reagents, the differences in reactivity among APTT reagents remain unclear. This study compared the reactivity of six commercial APTT reagents to argatroban in normal and abnormal plasma samples.</p>\n </section>\n \n <section>\n \n <h3> Materials and Methods</h3>\n \n <p>Normal samples were spiked with argatroban and five abnormal samples: low coagulation factor activity, high factor VIII, high factor VIIa, low fibrinogen, and high fibrinogen. Drug concentrations were adjusted to 0, 0.5, 1.0, 1.5, and 2.0 μg/mL in each plasma. Six APTT reagents, including silica or ellagic acid activator and phospholipids derived from synthetic or natural sources, were tested.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>The APTT ratio range among the six reagents was 2.4–3.2 in normal plasma at a concentration of 2.0 μg/mL. The sample showing the most expanded range was low coagulation activity (3.3–5.2), and the range in the sample with high factor VIII activity decreased (1.5–2.2).</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>A reactivity difference was observed in argatroban-spiked samples, which increased in abnormal plasma samples. APTT may not reflect the anticoagulant activity of argatroban in patients with abnormal coagulation activity. The reactivity of APTT should be confirmed in each laboratory, and patient background coagulation status should be assessed before monitoring is conducted using the APTT ratio.</p>\n </section>\n </div>","PeriodicalId":14120,"journal":{"name":"International Journal of Laboratory Hematology","volume":"47 5","pages":"923-930"},"PeriodicalIF":2.3000,"publicationDate":"2025-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/ijlh.14488","citationCount":"0","resultStr":"{\"title\":\"Variability of Argatroban Effects on the Multiple APTT Reagents in High and Low Coagulation Activity Samples\",\"authors\":\"Osamu Kumano,&nbsp;Masahiro Ieko,&nbsp;Teruto Hashiguchi,&nbsp;Takashi Ito,&nbsp;Satoshi Yamazaki,&nbsp;Sumiyoshi Naito,&nbsp;Masako Yamazaki\",\"doi\":\"10.1111/ijlh.14488\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Introduction</h3>\\n \\n <p>Argatroban is routinely monitored using activated partial thromboplastin time (APTT), with a recommended target range of 1.5–3.0 times. Although this range was established based on clinical trial data, including several APTT reagents, the differences in reactivity among APTT reagents remain unclear. This study compared the reactivity of six commercial APTT reagents to argatroban in normal and abnormal plasma samples.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Materials and Methods</h3>\\n \\n <p>Normal samples were spiked with argatroban and five abnormal samples: low coagulation factor activity, high factor VIII, high factor VIIa, low fibrinogen, and high fibrinogen. Drug concentrations were adjusted to 0, 0.5, 1.0, 1.5, and 2.0 μg/mL in each plasma. Six APTT reagents, including silica or ellagic acid activator and phospholipids derived from synthetic or natural sources, were tested.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>The APTT ratio range among the six reagents was 2.4–3.2 in normal plasma at a concentration of 2.0 μg/mL. The sample showing the most expanded range was low coagulation activity (3.3–5.2), and the range in the sample with high factor VIII activity decreased (1.5–2.2).</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>A reactivity difference was observed in argatroban-spiked samples, which increased in abnormal plasma samples. APTT may not reflect the anticoagulant activity of argatroban in patients with abnormal coagulation activity. The reactivity of APTT should be confirmed in each laboratory, and patient background coagulation status should be assessed before monitoring is conducted using the APTT ratio.</p>\\n </section>\\n </div>\",\"PeriodicalId\":14120,\"journal\":{\"name\":\"International Journal of Laboratory Hematology\",\"volume\":\"47 5\",\"pages\":\"923-930\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2025-04-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1111/ijlh.14488\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Laboratory Hematology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/ijlh.14488\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Laboratory Hematology","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/ijlh.14488","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

简介:阿加曲班常规监测使用活化部分凝血活酶时间(APTT),推荐的目标范围为1.5-3.0倍。虽然这个范围是根据临床试验数据建立的,包括几种APTT试剂,但APTT试剂之间的反应性差异尚不清楚。本研究比较了六种商用APTT试剂在正常和异常血浆样品中对阿加曲班的反应性。材料与方法:正常样品加加阿加曲班,正常样品加加低凝血因子活性、高凝血因子VIII、高凝血因子VIIa、低纤维蛋白原、高纤维蛋白原5种异常样品加标。各组血浆药物浓度分别调整为0、0.5、1.0、1.5、2.0 μg/mL。测试了六种APTT试剂,包括二氧化硅或鞣花酸活化剂和合成或天然来源的磷脂。结果:在浓度为2.0 μg/mL的正常血浆中,6种试剂的APTT比值范围为2.4 ~ 3.2。凝血活性低的样品范围扩大最大(3.3-5.2),凝血活性高的样品范围缩小(1.5-2.2)。结论:在加了阿加曲班的样品中观察到反应性差异,在异常血浆样品中反应性增加。APTT可能不能反映凝血活性异常患者阿加曲班的抗凝活性。应在各实验室确认APTT的反应性,并在使用APTT比值进行监测前评估患者的背景凝血状态。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Variability of Argatroban Effects on the Multiple APTT Reagents in High and Low Coagulation Activity Samples

Variability of Argatroban Effects on the Multiple APTT Reagents in High and Low Coagulation Activity Samples

Introduction

Argatroban is routinely monitored using activated partial thromboplastin time (APTT), with a recommended target range of 1.5–3.0 times. Although this range was established based on clinical trial data, including several APTT reagents, the differences in reactivity among APTT reagents remain unclear. This study compared the reactivity of six commercial APTT reagents to argatroban in normal and abnormal plasma samples.

Materials and Methods

Normal samples were spiked with argatroban and five abnormal samples: low coagulation factor activity, high factor VIII, high factor VIIa, low fibrinogen, and high fibrinogen. Drug concentrations were adjusted to 0, 0.5, 1.0, 1.5, and 2.0 μg/mL in each plasma. Six APTT reagents, including silica or ellagic acid activator and phospholipids derived from synthetic or natural sources, were tested.

Results

The APTT ratio range among the six reagents was 2.4–3.2 in normal plasma at a concentration of 2.0 μg/mL. The sample showing the most expanded range was low coagulation activity (3.3–5.2), and the range in the sample with high factor VIII activity decreased (1.5–2.2).

Conclusions

A reactivity difference was observed in argatroban-spiked samples, which increased in abnormal plasma samples. APTT may not reflect the anticoagulant activity of argatroban in patients with abnormal coagulation activity. The reactivity of APTT should be confirmed in each laboratory, and patient background coagulation status should be assessed before monitoring is conducted using the APTT ratio.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.50
自引率
6.70%
发文量
211
审稿时长
6-12 weeks
期刊介绍: The International Journal of Laboratory Hematology provides a forum for the communication of new developments, research topics and the practice of laboratory haematology. The journal publishes invited reviews, full length original articles, and correspondence. The International Journal of Laboratory Hematology is the official journal of the International Society for Laboratory Hematology, which addresses the following sub-disciplines: cellular analysis, flow cytometry, haemostasis and thrombosis, molecular diagnostics, haematology informatics, haemoglobinopathies, point of care testing, standards and guidelines. The journal was launched in 2006 as the successor to Clinical and Laboratory Hematology, which was first published in 1979. An active and positive editorial policy ensures that work of a high scientific standard is reported, in order to bridge the gap between practical and academic aspects of laboratory haematology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信