正畸清除矫正器治疗后超声对骨密度影响的初步研究。

IF 1.1 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Mohsen Gholizadeh, Hollis Lai, Lindsey Westover, Tarek El-Bialy
{"title":"正畸清除矫正器治疗后超声对骨密度影响的初步研究。","authors":"Mohsen Gholizadeh, Hollis Lai, Lindsey Westover, Tarek El-Bialy","doi":"10.2174/0115734056371884250324151755","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study evaluated the impact of Low-Intensity Pulsed Ultrasound (LIPUS) on bone radio density in patients undergoing orthodontic treatment with clear aligners, aiming to enhance bone remodeling and improve treatment stability.</p><p><strong>Methods: </strong>This retrospective study included 68 participants divided into two groups: 34 treated with LIPUS and 34 in a control group. Bone radio density was measured using Hounsfield units from CBCT scans before and after treatment. Statistical analyses included Mann-Whitney U tests and paired ttests.</p><p><strong>Results: </strong>The average age was 29.85 ± 14.85 years in the control group and 36.29 ± 12.78 years in the LIPUS group. Bone radio density in the upper arch of the LIPUS group significantly increased from 444.6 HU to 751.3 HU (p < 0.001), while the control group showed a slight decrease in the upper arch (657.4 HU to 650.5 HU, p = 0.86). In the lower arch, a similar trend was observed in the LIPUS group, with an increase from 767.7 HU to 823.4 HU (p = 0.17), though not statistically significant. There were no significant differences in post-treatment ABO DI scores between groups, suggesting equivalent effectiveness in achieving orthodontic outcomes.</p><p><strong>Conclusion: </strong>LIPUS with clear aligners seems promising in enhancing bone radio density, indicating an improved bone remodeling effect. This highlights LIPUS's potential as a beneficial adjunct in orthodontic treatments.</p>","PeriodicalId":54215,"journal":{"name":"Current Medical Imaging Reviews","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2025-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Impact of Therapeutic Ultrasound on Bone Radio Density Following Orthodontic Treatment with Clear Aligners: A Preliminary Study.\",\"authors\":\"Mohsen Gholizadeh, Hollis Lai, Lindsey Westover, Tarek El-Bialy\",\"doi\":\"10.2174/0115734056371884250324151755\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>This study evaluated the impact of Low-Intensity Pulsed Ultrasound (LIPUS) on bone radio density in patients undergoing orthodontic treatment with clear aligners, aiming to enhance bone remodeling and improve treatment stability.</p><p><strong>Methods: </strong>This retrospective study included 68 participants divided into two groups: 34 treated with LIPUS and 34 in a control group. Bone radio density was measured using Hounsfield units from CBCT scans before and after treatment. Statistical analyses included Mann-Whitney U tests and paired ttests.</p><p><strong>Results: </strong>The average age was 29.85 ± 14.85 years in the control group and 36.29 ± 12.78 years in the LIPUS group. Bone radio density in the upper arch of the LIPUS group significantly increased from 444.6 HU to 751.3 HU (p < 0.001), while the control group showed a slight decrease in the upper arch (657.4 HU to 650.5 HU, p = 0.86). In the lower arch, a similar trend was observed in the LIPUS group, with an increase from 767.7 HU to 823.4 HU (p = 0.17), though not statistically significant. There were no significant differences in post-treatment ABO DI scores between groups, suggesting equivalent effectiveness in achieving orthodontic outcomes.</p><p><strong>Conclusion: </strong>LIPUS with clear aligners seems promising in enhancing bone radio density, indicating an improved bone remodeling effect. This highlights LIPUS's potential as a beneficial adjunct in orthodontic treatments.</p>\",\"PeriodicalId\":54215,\"journal\":{\"name\":\"Current Medical Imaging Reviews\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2025-04-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Medical Imaging Reviews\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2174/0115734056371884250324151755\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Medical Imaging Reviews","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2174/0115734056371884250324151755","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价低强度脉冲超声(Low-Intensity Pulsed Ultrasound, LIPUS)对正畸使用透明矫正器治疗患者骨放射性密度的影响,旨在促进骨重塑,提高治疗稳定性。方法:本回顾性研究纳入68例受试者,分为两组:34例LIPUS治疗组和34例对照组。治疗前后用CBCT扫描的Hounsfield单位测量骨放射密度。统计分析包括Mann-Whitney U检验和配对检验。结果:对照组平均年龄29.85±14.85岁,LIPUS组平均年龄36.29±12.78岁。LIPUS组上弓骨放射密度由444.6 HU显著升高至751.3 HU (p < 0.001),而对照组上弓骨放射密度略有下降(由657.4 HU升高至650.5 HU, p = 0.86)。在下弓,LIPUS组观察到类似的趋势,从767.7 HU增加到823.4 HU (p = 0.17),尽管没有统计学意义。两组治疗后ABO DI评分无显著差异,表明在实现正畸结果方面具有同等的有效性。结论:LIPUS与清晰对准器似乎有希望提高骨放射性密度,表明改善骨重塑效果。这突出了LIPUS在正畸治疗中作为有益辅助剂的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Impact of Therapeutic Ultrasound on Bone Radio Density Following Orthodontic Treatment with Clear Aligners: A Preliminary Study.

Objective: This study evaluated the impact of Low-Intensity Pulsed Ultrasound (LIPUS) on bone radio density in patients undergoing orthodontic treatment with clear aligners, aiming to enhance bone remodeling and improve treatment stability.

Methods: This retrospective study included 68 participants divided into two groups: 34 treated with LIPUS and 34 in a control group. Bone radio density was measured using Hounsfield units from CBCT scans before and after treatment. Statistical analyses included Mann-Whitney U tests and paired ttests.

Results: The average age was 29.85 ± 14.85 years in the control group and 36.29 ± 12.78 years in the LIPUS group. Bone radio density in the upper arch of the LIPUS group significantly increased from 444.6 HU to 751.3 HU (p < 0.001), while the control group showed a slight decrease in the upper arch (657.4 HU to 650.5 HU, p = 0.86). In the lower arch, a similar trend was observed in the LIPUS group, with an increase from 767.7 HU to 823.4 HU (p = 0.17), though not statistically significant. There were no significant differences in post-treatment ABO DI scores between groups, suggesting equivalent effectiveness in achieving orthodontic outcomes.

Conclusion: LIPUS with clear aligners seems promising in enhancing bone radio density, indicating an improved bone remodeling effect. This highlights LIPUS's potential as a beneficial adjunct in orthodontic treatments.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.60
自引率
0.00%
发文量
246
审稿时长
1 months
期刊介绍: Current Medical Imaging Reviews publishes frontier review articles, original research articles, drug clinical trial studies and guest edited thematic issues on all the latest advances on medical imaging dedicated to clinical research. All relevant areas are covered by the journal, including advances in the diagnosis, instrumentation and therapeutic applications related to all modern medical imaging techniques. The journal is essential reading for all clinicians and researchers involved in medical imaging and diagnosis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信