{"title":"新型材料交联聚异丁烯人工晶状体植入术的安全性和稳定性评价:初步研究。","authors":"Yinying Zhao, Jing Jin, Fuman Yang, Man Hu, Pingjun Chang, Zhangliang Li, Dandan Wang, Hengli Lian, Jiayan Fang, Ziqi Meng, Yune Zhao","doi":"10.1097/j.jcrs.0000000000001685","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the safety and stability of an intraocular lens(IOL) made of crosslinked polyisobutylene (xPIB), a novel biomaterial for new-generation foldable IOL.</p><p><strong>Setting: </strong>Eye Hospital of Wenzhou Medical University, Hangzhou, Zhejiang Province, China.</p><p><strong>Design: </strong>Prospective observational study.</p><p><strong>Methods: </strong>This was a prospective, parallel-controlled, randomised clinical study. Participants were randomly enrolled in a 1:1 ratio and underwent one-eye cataract removal with either xPIB or Acrysof (control) IOL implantation. The follow-up schedule was 1 day, 1 week, 1, 3, and 6 months, and 1 year after implantation. Various ocular biometric parameters were recorded and compared between the two groups.</p><p><strong>Results: </strong>Precisely 38 (19 per group) participants were included in this study. All surgeries were performed successfully. The xPIB IOL showed less decentration than the Acrysof IOL [0.16 (0.08,0.21) vs. 0.18 (0.12,0.21) mm] 1 week after surgery (P=0.032). The anterior capsule opening area decreased during the trial, with more shrinkage in the xPIB than in the Acrysof IOL (P<0.05 at all-time points). The anterior capsule contraction negatively correlated with the changes in postoperative aqueous depth from 1 week to 6 months (r=-0.671, P=0.002) and was uncorrelated with the changes in spherical equivalent at all-time points (P>0.05). The differences in other ocular parameters were not statistically significant between the two groups (P<0.05).</p><p><strong>Conclusions: </strong>The new xPIB IOL exhibited excellent in-the-bag stability and visual rehabilitation after cataract removal. Although the incidence was higher, the anterior capsule contraction in the xPIB group was not clinically significant and did not negatively impact vision.</p>","PeriodicalId":15214,"journal":{"name":"Journal of cataract and refractive surgery","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2025-05-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of safety and stability after intraocular lens implantation using a novel material-crosslinked polyisobutylene: A preliminary study.\",\"authors\":\"Yinying Zhao, Jing Jin, Fuman Yang, Man Hu, Pingjun Chang, Zhangliang Li, Dandan Wang, Hengli Lian, Jiayan Fang, Ziqi Meng, Yune Zhao\",\"doi\":\"10.1097/j.jcrs.0000000000001685\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the safety and stability of an intraocular lens(IOL) made of crosslinked polyisobutylene (xPIB), a novel biomaterial for new-generation foldable IOL.</p><p><strong>Setting: </strong>Eye Hospital of Wenzhou Medical University, Hangzhou, Zhejiang Province, China.</p><p><strong>Design: </strong>Prospective observational study.</p><p><strong>Methods: </strong>This was a prospective, parallel-controlled, randomised clinical study. Participants were randomly enrolled in a 1:1 ratio and underwent one-eye cataract removal with either xPIB or Acrysof (control) IOL implantation. The follow-up schedule was 1 day, 1 week, 1, 3, and 6 months, and 1 year after implantation. Various ocular biometric parameters were recorded and compared between the two groups.</p><p><strong>Results: </strong>Precisely 38 (19 per group) participants were included in this study. All surgeries were performed successfully. The xPIB IOL showed less decentration than the Acrysof IOL [0.16 (0.08,0.21) vs. 0.18 (0.12,0.21) mm] 1 week after surgery (P=0.032). The anterior capsule opening area decreased during the trial, with more shrinkage in the xPIB than in the Acrysof IOL (P<0.05 at all-time points). The anterior capsule contraction negatively correlated with the changes in postoperative aqueous depth from 1 week to 6 months (r=-0.671, P=0.002) and was uncorrelated with the changes in spherical equivalent at all-time points (P>0.05). The differences in other ocular parameters were not statistically significant between the two groups (P<0.05).</p><p><strong>Conclusions: </strong>The new xPIB IOL exhibited excellent in-the-bag stability and visual rehabilitation after cataract removal. Although the incidence was higher, the anterior capsule contraction in the xPIB group was not clinically significant and did not negatively impact vision.</p>\",\"PeriodicalId\":15214,\"journal\":{\"name\":\"Journal of cataract and refractive surgery\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2025-05-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of cataract and refractive surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/j.jcrs.0000000000001685\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cataract and refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/j.jcrs.0000000000001685","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Evaluation of safety and stability after intraocular lens implantation using a novel material-crosslinked polyisobutylene: A preliminary study.
Purpose: To evaluate the safety and stability of an intraocular lens(IOL) made of crosslinked polyisobutylene (xPIB), a novel biomaterial for new-generation foldable IOL.
Setting: Eye Hospital of Wenzhou Medical University, Hangzhou, Zhejiang Province, China.
Design: Prospective observational study.
Methods: This was a prospective, parallel-controlled, randomised clinical study. Participants were randomly enrolled in a 1:1 ratio and underwent one-eye cataract removal with either xPIB or Acrysof (control) IOL implantation. The follow-up schedule was 1 day, 1 week, 1, 3, and 6 months, and 1 year after implantation. Various ocular biometric parameters were recorded and compared between the two groups.
Results: Precisely 38 (19 per group) participants were included in this study. All surgeries were performed successfully. The xPIB IOL showed less decentration than the Acrysof IOL [0.16 (0.08,0.21) vs. 0.18 (0.12,0.21) mm] 1 week after surgery (P=0.032). The anterior capsule opening area decreased during the trial, with more shrinkage in the xPIB than in the Acrysof IOL (P<0.05 at all-time points). The anterior capsule contraction negatively correlated with the changes in postoperative aqueous depth from 1 week to 6 months (r=-0.671, P=0.002) and was uncorrelated with the changes in spherical equivalent at all-time points (P>0.05). The differences in other ocular parameters were not statistically significant between the two groups (P<0.05).
Conclusions: The new xPIB IOL exhibited excellent in-the-bag stability and visual rehabilitation after cataract removal. Although the incidence was higher, the anterior capsule contraction in the xPIB group was not clinically significant and did not negatively impact vision.
期刊介绍:
The Journal of Cataract & Refractive Surgery (JCRS), a preeminent peer-reviewed monthly ophthalmology publication, is the official journal of the American Society of Cataract and Refractive Surgery (ASCRS) and the European Society of Cataract and Refractive Surgeons (ESCRS).
JCRS publishes high quality articles on all aspects of anterior segment surgery. In addition to original clinical studies, the journal features a consultation section, practical techniques, important cases, and reviews as well as basic science articles.