Lucas Kreiss, Melissa Wu, Michael Wayne, Shiqi Xu, Paul McKee, Derrick Dwamena, Kanghyun Kim, Kyung Chul Lee, Kyle R Cowdrick, Wenhui Liu, Arin Ülkü, Mark Harfouche, Xi Yang, Clare Cook, Seung Ah Lee, Erin Buckley, Claudio Bruschini, Edoardo Charbon, Scott Huettel, Roarke Horstmeyer
{"title":"表面之下:用大规模并行漫射相关光谱揭示人体受试者的深层组织血流。","authors":"Lucas Kreiss, Melissa Wu, Michael Wayne, Shiqi Xu, Paul McKee, Derrick Dwamena, Kanghyun Kim, Kyung Chul Lee, Kyle R Cowdrick, Wenhui Liu, Arin Ülkü, Mark Harfouche, Xi Yang, Clare Cook, Seung Ah Lee, Erin Buckley, Claudio Bruschini, Edoardo Charbon, Scott Huettel, Roarke Horstmeyer","doi":"10.1117/1.NPh.12.2.025007","DOIUrl":null,"url":null,"abstract":"<p><strong>Significance: </strong>Diffuse correlation spectroscopy (DCS) allows label-free, non-invasive investigation of microvascular dynamics deep within tissue, such as cerebral blood flow (CBF). However, the signal-to-noise ratio (SNR) in DCS limits its effective cerebral sensitivity in adults, in which the depth to the brain, through the scalp and skull, is substantially larger than in infants.</p><p><strong>Aim: </strong>Therefore, we aim to increase its SNR and, ultimately, its sensitivity to CBF through new DCS techniques.</p><p><strong>Approach: </strong>We present an <i>in vivo</i> demonstration of parallelized DCS (PDCS) to measure cerebral and muscular blood flow in healthy adults. Our setup employs an innovative array with hundreds of thousands single photon avalanche diodes (SPAD) in a <math><mrow><mn>500</mn> <mo>×</mo> <mn>500</mn></mrow> </math> grid to boost SNR by averaging all independent pixel measurements. We tested this device on different total pixel counts and frame rates. A secondary, smaller array was used for reference measurements from shallower tissue at lower source-detector-separation (SDS).</p><p><strong>Results: </strong>The new system can measure pulsatile blood flow in cerebral and muscular tissue, at up to 4 cm SDS, while maintaining a similar measurement noise as compared with a previously published <math><mrow><mn>32</mn> <mo>×</mo> <mn>32</mn></mrow> </math> PDCS system at 1.5 cm SDS. Data from a cohort of 15 adults provide strong experimental evidence for functional CBF activity during a cognitive memory task and allowed analysis of pulse markers. Additional control experiments on muscular blood flow in the forearm with a different technical configuration provide converging evidence for the efficacy of this technique.</p><p><strong>Conclusions: </strong>Our results outline successful PDCS measurements with large SPAD arrays to enable detect CBF in human adults. The ongoing development of SPAD camera technology is expected to result in larger and faster detectors in the future. In combination with new data processing techniques, tailored for the sparse signal of binary photon detection events in SPADs, this could lead to even greater SNR increase and ultimately greater depth sensitivity of PDCS.</p>","PeriodicalId":54335,"journal":{"name":"Neurophotonics","volume":"12 2","pages":"025007"},"PeriodicalIF":4.8000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11981687/pdf/","citationCount":"0","resultStr":"{\"title\":\"Beneath the surface: revealing deep-tissue blood flow in human subjects with massively parallelized diffuse correlation spectroscopy.\",\"authors\":\"Lucas Kreiss, Melissa Wu, Michael Wayne, Shiqi Xu, Paul McKee, Derrick Dwamena, Kanghyun Kim, Kyung Chul Lee, Kyle R Cowdrick, Wenhui Liu, Arin Ülkü, Mark Harfouche, Xi Yang, Clare Cook, Seung Ah Lee, Erin Buckley, Claudio Bruschini, Edoardo Charbon, Scott Huettel, Roarke Horstmeyer\",\"doi\":\"10.1117/1.NPh.12.2.025007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Significance: </strong>Diffuse correlation spectroscopy (DCS) allows label-free, non-invasive investigation of microvascular dynamics deep within tissue, such as cerebral blood flow (CBF). However, the signal-to-noise ratio (SNR) in DCS limits its effective cerebral sensitivity in adults, in which the depth to the brain, through the scalp and skull, is substantially larger than in infants.</p><p><strong>Aim: </strong>Therefore, we aim to increase its SNR and, ultimately, its sensitivity to CBF through new DCS techniques.</p><p><strong>Approach: </strong>We present an <i>in vivo</i> demonstration of parallelized DCS (PDCS) to measure cerebral and muscular blood flow in healthy adults. Our setup employs an innovative array with hundreds of thousands single photon avalanche diodes (SPAD) in a <math><mrow><mn>500</mn> <mo>×</mo> <mn>500</mn></mrow> </math> grid to boost SNR by averaging all independent pixel measurements. We tested this device on different total pixel counts and frame rates. A secondary, smaller array was used for reference measurements from shallower tissue at lower source-detector-separation (SDS).</p><p><strong>Results: </strong>The new system can measure pulsatile blood flow in cerebral and muscular tissue, at up to 4 cm SDS, while maintaining a similar measurement noise as compared with a previously published <math><mrow><mn>32</mn> <mo>×</mo> <mn>32</mn></mrow> </math> PDCS system at 1.5 cm SDS. Data from a cohort of 15 adults provide strong experimental evidence for functional CBF activity during a cognitive memory task and allowed analysis of pulse markers. Additional control experiments on muscular blood flow in the forearm with a different technical configuration provide converging evidence for the efficacy of this technique.</p><p><strong>Conclusions: </strong>Our results outline successful PDCS measurements with large SPAD arrays to enable detect CBF in human adults. The ongoing development of SPAD camera technology is expected to result in larger and faster detectors in the future. In combination with new data processing techniques, tailored for the sparse signal of binary photon detection events in SPADs, this could lead to even greater SNR increase and ultimately greater depth sensitivity of PDCS.</p>\",\"PeriodicalId\":54335,\"journal\":{\"name\":\"Neurophotonics\",\"volume\":\"12 2\",\"pages\":\"025007\"},\"PeriodicalIF\":4.8000,\"publicationDate\":\"2025-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11981687/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Neurophotonics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1117/1.NPh.12.2.025007\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/4/9 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"NEUROSCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neurophotonics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1117/1.NPh.12.2.025007","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/4/9 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
引用次数: 0
摘要
意义:漫射相关光谱(DCS)允许无标记、无创地研究组织深处的微血管动力学,如脑血流量(CBF)。然而,DCS的信噪比(SNR)限制了其在成人中的有效大脑灵敏度,成人通过头皮和颅骨到达大脑的深度比婴儿大得多。目的:因此,我们的目标是通过新的DCS技术提高其信噪比,并最终提高其对CBF的敏感性。方法:我们提出了并行DCS (PDCS)在体内的演示,以测量健康成人的大脑和肌肉血流量。我们的设置采用了一个创新的阵列,在500 × 500的网格中有数十万个单光子雪崩二极管(SPAD),通过平均所有独立的像素测量来提高信噪比。我们在不同的总像素数和帧速率下测试了这款设备。在较低的源-检测器-分离(SDS)下,二级较小的阵列用于较浅组织的参考测量。结果:新系统可以测量高达4 cm SDS的大脑和肌肉组织的脉动血流量,同时与先前发表的1.5 cm SDS的32 × 32 PDCS系统相比,保持相似的测量噪声。来自15名成年人队列的数据提供了强有力的实验证据,证明了认知记忆任务期间CBF的功能性活动,并允许对脉搏标记物进行分析。另外对前臂肌肉血流进行的不同技术配置的对照实验为该技术的有效性提供了越来越多的证据。结论:我们的结果概述了成功的PDCS测量与大型SPAD阵列能够检测成人的CBF。SPAD相机技术的持续发展有望在未来产生更大更快的探测器。结合新的数据处理技术,为spad中二元光子探测事件的稀疏信号量身定制,这可能会导致更大的信噪比增加,最终提高PDCS的深度灵敏度。
Beneath the surface: revealing deep-tissue blood flow in human subjects with massively parallelized diffuse correlation spectroscopy.
Significance: Diffuse correlation spectroscopy (DCS) allows label-free, non-invasive investigation of microvascular dynamics deep within tissue, such as cerebral blood flow (CBF). However, the signal-to-noise ratio (SNR) in DCS limits its effective cerebral sensitivity in adults, in which the depth to the brain, through the scalp and skull, is substantially larger than in infants.
Aim: Therefore, we aim to increase its SNR and, ultimately, its sensitivity to CBF through new DCS techniques.
Approach: We present an in vivo demonstration of parallelized DCS (PDCS) to measure cerebral and muscular blood flow in healthy adults. Our setup employs an innovative array with hundreds of thousands single photon avalanche diodes (SPAD) in a grid to boost SNR by averaging all independent pixel measurements. We tested this device on different total pixel counts and frame rates. A secondary, smaller array was used for reference measurements from shallower tissue at lower source-detector-separation (SDS).
Results: The new system can measure pulsatile blood flow in cerebral and muscular tissue, at up to 4 cm SDS, while maintaining a similar measurement noise as compared with a previously published PDCS system at 1.5 cm SDS. Data from a cohort of 15 adults provide strong experimental evidence for functional CBF activity during a cognitive memory task and allowed analysis of pulse markers. Additional control experiments on muscular blood flow in the forearm with a different technical configuration provide converging evidence for the efficacy of this technique.
Conclusions: Our results outline successful PDCS measurements with large SPAD arrays to enable detect CBF in human adults. The ongoing development of SPAD camera technology is expected to result in larger and faster detectors in the future. In combination with new data processing techniques, tailored for the sparse signal of binary photon detection events in SPADs, this could lead to even greater SNR increase and ultimately greater depth sensitivity of PDCS.
期刊介绍:
At the interface of optics and neuroscience, Neurophotonics is a peer-reviewed journal that covers advances in optical technology applicable to study of the brain and their impact on the basic and clinical neuroscience applications.