nDSEK与DSEK供受者界面改变及视觉效果的比较与相关性

IF 1.9 4区 医学 Q3 OPHTHALMOLOGY
Journal of Ophthalmology Pub Date : 2025-03-12 eCollection Date: 2025-01-01 DOI:10.1155/joph/2066562
Minghai Huang, Thuthuy Hoang, Guina Yin, Yanqing Liang, Zhifeng Wu, Jian Teng, Zhuoyuan Zhang, Dongmei Wei
{"title":"nDSEK与DSEK供受者界面改变及视觉效果的比较与相关性","authors":"Minghai Huang, Thuthuy Hoang, Guina Yin, Yanqing Liang, Zhifeng Wu, Jian Teng, Zhuoyuan Zhang, Dongmei Wei","doi":"10.1155/joph/2066562","DOIUrl":null,"url":null,"abstract":"<p><p><b>Purpose:</b> This study aimed to compare the donor-recipient interface changes between non-Descemet stripping endothelial keratoplasty (nDSEK) and Descemet stripping endothelial keratoplasty (DSEK) and assess their correlation with the postoperative best spectacle-corrected visual acuity (BCVA). <b>Methods:</b> This retrospective study collected clinical data on patients with corneal endothelial decompensation who underwent either nDSEK or DSEK between August 2019 and April 2023. The donor-recipient interface particle density, interface haze, visual outcome, and graft dislocation were compared between nDSEK and DSEK groups. <b>Results:</b> A total of 66 eyes from 66 patients (nDSEK <i>n</i>: 31 eyes and DSEK <i>n</i>: 35 eyes) were included. At 12 months postoperatively, nDSEK had a mean interface particle density of 631.97 ± 143.95 particles/mm<sup>2</sup>, significantly higher than DSEK's 518.20 ± 121.72 particles/mm<sup>2</sup> (<i>p</i>=0.001). The interface haze was also greater in nDSEK (78.16 ± 13.74) compared with DSEK (64.21 ± 14.78) (<i>p</i> < 0.001). BCVA improved similarly in both groups, with nDSEK changing from 1.92 ± 0.26 to 0.37 ± 0.11 and DSEK from 1.85 ± 0.24 to 0.34 ± 0.10 (<i>p</i>=0.149). Correlation analysis revealed a significant association between interface particle density and interface haze in both the nDSEK (correlation coefficient: 0.716, <i>p</i> < 0.001) and DSEK (correlation coefficient: 0.618, <i>p</i> < 0.001) groups. However, there was no significant correlation between interface particle density and postoperative BCVA for either the nDSEK (correlation coefficient: -0.028, <i>p</i>=0.883) or DSEK (correlation coefficient: 0.111, <i>p</i>=0.525) group. Similarly, no significant correlation was found between interface haze and postoperative BCVA in both groups (nDSEK: correlation coefficient: -0.080, <i>p</i>=0.670 and DSEK: correlation coefficient: -0.210, <i>p</i>=0.227). Graft dislocation rates were comparable: 3.2% in nDSEK and 2.9% in DSEK (<i>p</i>=0.931). <b>Conclusion:</b> nDSEK exhibited more interface particles and haze than standard DSEK, but visual outcomes and graft attachment were similarly effective.</p>","PeriodicalId":16674,"journal":{"name":"Journal of Ophthalmology","volume":"2025 ","pages":"2066562"},"PeriodicalIF":1.9000,"publicationDate":"2025-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11991815/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparison and Correlation of the Donor-Recipient Interface Changes and Visual Outcomes Between nDSEK and DSEK.\",\"authors\":\"Minghai Huang, Thuthuy Hoang, Guina Yin, Yanqing Liang, Zhifeng Wu, Jian Teng, Zhuoyuan Zhang, Dongmei Wei\",\"doi\":\"10.1155/joph/2066562\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Purpose:</b> This study aimed to compare the donor-recipient interface changes between non-Descemet stripping endothelial keratoplasty (nDSEK) and Descemet stripping endothelial keratoplasty (DSEK) and assess their correlation with the postoperative best spectacle-corrected visual acuity (BCVA). <b>Methods:</b> This retrospective study collected clinical data on patients with corneal endothelial decompensation who underwent either nDSEK or DSEK between August 2019 and April 2023. The donor-recipient interface particle density, interface haze, visual outcome, and graft dislocation were compared between nDSEK and DSEK groups. <b>Results:</b> A total of 66 eyes from 66 patients (nDSEK <i>n</i>: 31 eyes and DSEK <i>n</i>: 35 eyes) were included. At 12 months postoperatively, nDSEK had a mean interface particle density of 631.97 ± 143.95 particles/mm<sup>2</sup>, significantly higher than DSEK's 518.20 ± 121.72 particles/mm<sup>2</sup> (<i>p</i>=0.001). The interface haze was also greater in nDSEK (78.16 ± 13.74) compared with DSEK (64.21 ± 14.78) (<i>p</i> < 0.001). BCVA improved similarly in both groups, with nDSEK changing from 1.92 ± 0.26 to 0.37 ± 0.11 and DSEK from 1.85 ± 0.24 to 0.34 ± 0.10 (<i>p</i>=0.149). Correlation analysis revealed a significant association between interface particle density and interface haze in both the nDSEK (correlation coefficient: 0.716, <i>p</i> < 0.001) and DSEK (correlation coefficient: 0.618, <i>p</i> < 0.001) groups. However, there was no significant correlation between interface particle density and postoperative BCVA for either the nDSEK (correlation coefficient: -0.028, <i>p</i>=0.883) or DSEK (correlation coefficient: 0.111, <i>p</i>=0.525) group. Similarly, no significant correlation was found between interface haze and postoperative BCVA in both groups (nDSEK: correlation coefficient: -0.080, <i>p</i>=0.670 and DSEK: correlation coefficient: -0.210, <i>p</i>=0.227). Graft dislocation rates were comparable: 3.2% in nDSEK and 2.9% in DSEK (<i>p</i>=0.931). <b>Conclusion:</b> nDSEK exhibited more interface particles and haze than standard DSEK, but visual outcomes and graft attachment were similarly effective.</p>\",\"PeriodicalId\":16674,\"journal\":{\"name\":\"Journal of Ophthalmology\",\"volume\":\"2025 \",\"pages\":\"2066562\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2025-03-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11991815/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1155/joph/2066562\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1155/joph/2066562","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在比较非Descemet剥脱内皮角膜移植术(nDSEK)和Descemet剥脱内皮角膜移植术(DSEK)的供受体界面变化,并评估其与术后最佳眼镜矫正视力(BCVA)的相关性。方法:本回顾性研究收集了2019年8月至2023年4月期间接受nDSEK或DSEK治疗的角膜内皮失代偿患者的临床资料。比较nDSEK组和DSEK组供受体界面颗粒密度、界面雾度、视觉效果和移植物错位。结果:共纳入66例患者66只眼(nDSEK n: 31眼,DSEK n: 35眼)。术后12个月,nDSEK的平均界面粒子密度为631.97±143.95个粒子/mm2,显著高于DSEK的518.20±121.72个粒子/mm2 (p=0.001)。nDSEK的界面雾霾(78.16±13.74)高于DSEK(64.21±14.78)(p < 0.001)。两组BCVA的改善相似,nDSEK从1.92±0.26变为0.37±0.11,DSEK从1.85±0.24变为0.34±0.10 (p=0.149)。相关分析显示,nDSEK组(相关系数为0.716,p < 0.001)和DSEK组(相关系数为0.618,p < 0.001)界面颗粒密度与界面雾霾之间存在显著相关。然而,无论是nDSEK组(相关系数:-0.028,p=0.883)还是DSEK组(相关系数:0.111,p=0.525),界面颗粒密度与术后BCVA均无显著相关性。同样,两组患者界面雾度与术后BCVA无显著相关性(nDSEK:相关系数:-0.080,p=0.670; DSEK:相关系数:-0.210,p=0.227)。移植物脱位率具有可比性:nDSEK组为3.2%,DSEK组为2.9% (p=0.931)。结论:与标准DSEK相比,nDSEK表现出更多的界面颗粒和雾霾,但视觉效果和移植物附着效果相似。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison and Correlation of the Donor-Recipient Interface Changes and Visual Outcomes Between nDSEK and DSEK.

Purpose: This study aimed to compare the donor-recipient interface changes between non-Descemet stripping endothelial keratoplasty (nDSEK) and Descemet stripping endothelial keratoplasty (DSEK) and assess their correlation with the postoperative best spectacle-corrected visual acuity (BCVA). Methods: This retrospective study collected clinical data on patients with corneal endothelial decompensation who underwent either nDSEK or DSEK between August 2019 and April 2023. The donor-recipient interface particle density, interface haze, visual outcome, and graft dislocation were compared between nDSEK and DSEK groups. Results: A total of 66 eyes from 66 patients (nDSEK n: 31 eyes and DSEK n: 35 eyes) were included. At 12 months postoperatively, nDSEK had a mean interface particle density of 631.97 ± 143.95 particles/mm2, significantly higher than DSEK's 518.20 ± 121.72 particles/mm2 (p=0.001). The interface haze was also greater in nDSEK (78.16 ± 13.74) compared with DSEK (64.21 ± 14.78) (p < 0.001). BCVA improved similarly in both groups, with nDSEK changing from 1.92 ± 0.26 to 0.37 ± 0.11 and DSEK from 1.85 ± 0.24 to 0.34 ± 0.10 (p=0.149). Correlation analysis revealed a significant association between interface particle density and interface haze in both the nDSEK (correlation coefficient: 0.716, p < 0.001) and DSEK (correlation coefficient: 0.618, p < 0.001) groups. However, there was no significant correlation between interface particle density and postoperative BCVA for either the nDSEK (correlation coefficient: -0.028, p=0.883) or DSEK (correlation coefficient: 0.111, p=0.525) group. Similarly, no significant correlation was found between interface haze and postoperative BCVA in both groups (nDSEK: correlation coefficient: -0.080, p=0.670 and DSEK: correlation coefficient: -0.210, p=0.227). Graft dislocation rates were comparable: 3.2% in nDSEK and 2.9% in DSEK (p=0.931). Conclusion: nDSEK exhibited more interface particles and haze than standard DSEK, but visual outcomes and graft attachment were similarly effective.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Ophthalmology
Journal of Ophthalmology MEDICINE, RESEARCH & EXPERIMENTAL-OPHTHALMOLOGY
CiteScore
4.30
自引率
5.30%
发文量
194
审稿时长
6-12 weeks
期刊介绍: Journal of Ophthalmology is a peer-reviewed, Open Access journal that publishes original research articles, review articles, and clinical studies related to the anatomy, physiology and diseases of the eye. Submissions should focus on new diagnostic and surgical techniques, instrument and therapy updates, as well as clinical trials and research findings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信