冠状动脉疾病患者舒张期无充血率:一项前瞻性观察研究

IF 3 3区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Ji Woong Roh, Oh-Hyun Lee, Yongcheol Kim, Seok-Jae Heo, Eui Im, Deok-Kyu Cho
{"title":"冠状动脉疾病患者舒张期无充血率:一项前瞻性观察研究","authors":"Ji Woong Roh, Oh-Hyun Lee, Yongcheol Kim, Seok-Jae Heo, Eui Im, Deok-Kyu Cho","doi":"10.4070/kcj.2024.0351","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objectives: </strong>Diastolic hyperemia-free ratio (DFR), an alternative to fractional flow reserve (FFR) for the assessment of intermediate coronary artery stenosis, helps reduce patients' time, and inconvenience. However, the validation data for DFR and FFR are lacking. We aimed to evaluate the diagnostic accuracy of DFR and FFR and to assess the effective decision making for revascularization using their values.</p><p><strong>Methods: </strong>Patients subjected to an invasive physiological study for intermediate coronary artery stenosis at a single center in South Korea between August 2022 and January 2024 were prospectively recruited. We evaluated the correlation between DFR and FFR measurements and the diagnostic accuracy of DFR ≤0.89 to predict FFR ≤ 0.80. We also compared the correlation for each coronary artery.</p><p><strong>Results: </strong>A total of 324 intermediate coronary stenotic lesions from 300 patients were evaluated using DFR and FFR values simultaneously. There was a strong linear relationship between DFR and FFR (r = 0.80; 95% confidence interval [CI], 0.76-0.84; p < 0.001). The diagnostic accuracy of the DFR was 92.0% in predicting FFR ≤0.80. When compared separately for each coronary artery, all vessels showed a strong linear relationship with no statistical differences between any of the vessels (p=0.641). There was also a strong linear relationship between DFR and distal coronary pressure/aorta pressure (r=0.93; 95% CI, 0.91-0.94; p<0.001).</p><p><strong>Conclusions: </strong>There was a strong correlation between DFR and FFR and a high diagnostic accuracy rate of DFR compared to FFR. Good diagnostic performance of DFR was also observed in each coronary artery.</p><p><strong>Trial registration: </strong>ClinicalTrials.gov Identifier: NCT05421169.</p>","PeriodicalId":17850,"journal":{"name":"Korean Circulation Journal","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-02-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Diastolic Hyperemia-Free Ratio in Patients With Coronary Artery Disease: A Prospective Observational Study.\",\"authors\":\"Ji Woong Roh, Oh-Hyun Lee, Yongcheol Kim, Seok-Jae Heo, Eui Im, Deok-Kyu Cho\",\"doi\":\"10.4070/kcj.2024.0351\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and objectives: </strong>Diastolic hyperemia-free ratio (DFR), an alternative to fractional flow reserve (FFR) for the assessment of intermediate coronary artery stenosis, helps reduce patients' time, and inconvenience. However, the validation data for DFR and FFR are lacking. We aimed to evaluate the diagnostic accuracy of DFR and FFR and to assess the effective decision making for revascularization using their values.</p><p><strong>Methods: </strong>Patients subjected to an invasive physiological study for intermediate coronary artery stenosis at a single center in South Korea between August 2022 and January 2024 were prospectively recruited. We evaluated the correlation between DFR and FFR measurements and the diagnostic accuracy of DFR ≤0.89 to predict FFR ≤ 0.80. We also compared the correlation for each coronary artery.</p><p><strong>Results: </strong>A total of 324 intermediate coronary stenotic lesions from 300 patients were evaluated using DFR and FFR values simultaneously. There was a strong linear relationship between DFR and FFR (r = 0.80; 95% confidence interval [CI], 0.76-0.84; p < 0.001). The diagnostic accuracy of the DFR was 92.0% in predicting FFR ≤0.80. When compared separately for each coronary artery, all vessels showed a strong linear relationship with no statistical differences between any of the vessels (p=0.641). There was also a strong linear relationship between DFR and distal coronary pressure/aorta pressure (r=0.93; 95% CI, 0.91-0.94; p<0.001).</p><p><strong>Conclusions: </strong>There was a strong correlation between DFR and FFR and a high diagnostic accuracy rate of DFR compared to FFR. Good diagnostic performance of DFR was also observed in each coronary artery.</p><p><strong>Trial registration: </strong>ClinicalTrials.gov Identifier: NCT05421169.</p>\",\"PeriodicalId\":17850,\"journal\":{\"name\":\"Korean Circulation Journal\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-02-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Korean Circulation Journal\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4070/kcj.2024.0351\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Circulation Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4070/kcj.2024.0351","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景和目的:舒张无充血比(DFR)是评估中间冠状动脉狭窄的一种替代分数血流储备(FFR)的方法,有助于减少患者的时间和不便。然而,DFR和FFR的验证数据缺乏。我们的目的是评估DFR和FFR的诊断准确性,并利用它们的价值评估血运重建的有效决策。方法:前瞻性招募2022年8月至2024年1月在韩国单一中心接受中度冠状动脉狭窄侵袭性生理研究的患者。我们评估DFR和FFR测量之间的相关性,DFR≤0.89预测FFR≤0.80的诊断准确性。我们还比较了每条冠状动脉的相关性。结果:采用DFR和FFR同时对300例患者的324个中间冠状动脉狭窄病变进行评估。DFR与FFR之间存在较强的线性关系(r = 0.80;95%置信区间[CI], 0.76-0.84;结论:DFR与FFR有较强的相关性,DFR的诊断准确率高于FFR。DFR在各冠状动脉均有良好的诊断效果。试验注册:ClinicalTrials.gov标识符:NCT05421169。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Diastolic Hyperemia-Free Ratio in Patients With Coronary Artery Disease: A Prospective Observational Study.

Background and objectives: Diastolic hyperemia-free ratio (DFR), an alternative to fractional flow reserve (FFR) for the assessment of intermediate coronary artery stenosis, helps reduce patients' time, and inconvenience. However, the validation data for DFR and FFR are lacking. We aimed to evaluate the diagnostic accuracy of DFR and FFR and to assess the effective decision making for revascularization using their values.

Methods: Patients subjected to an invasive physiological study for intermediate coronary artery stenosis at a single center in South Korea between August 2022 and January 2024 were prospectively recruited. We evaluated the correlation between DFR and FFR measurements and the diagnostic accuracy of DFR ≤0.89 to predict FFR ≤ 0.80. We also compared the correlation for each coronary artery.

Results: A total of 324 intermediate coronary stenotic lesions from 300 patients were evaluated using DFR and FFR values simultaneously. There was a strong linear relationship between DFR and FFR (r = 0.80; 95% confidence interval [CI], 0.76-0.84; p < 0.001). The diagnostic accuracy of the DFR was 92.0% in predicting FFR ≤0.80. When compared separately for each coronary artery, all vessels showed a strong linear relationship with no statistical differences between any of the vessels (p=0.641). There was also a strong linear relationship between DFR and distal coronary pressure/aorta pressure (r=0.93; 95% CI, 0.91-0.94; p<0.001).

Conclusions: There was a strong correlation between DFR and FFR and a high diagnostic accuracy rate of DFR compared to FFR. Good diagnostic performance of DFR was also observed in each coronary artery.

Trial registration: ClinicalTrials.gov Identifier: NCT05421169.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Korean Circulation Journal
Korean Circulation Journal CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
4.90
自引率
17.20%
发文量
103
期刊介绍: Korean Circulation Journal is the official journal of the Korean Society of Cardiology, the Korean Pediatric Heart Society, the Korean Society of Interventional Cardiology, and the Korean Society of Heart Failure. Abbreviated title is ''Korean Circ J''. Korean Circulation Journal, established in 1971, is a professional, peer-reviewed journal covering all aspects of cardiovascular medicine, including original articles of basic research and clinical findings, review articles, editorials, images in cardiovascular medicine, and letters to the editor. Korean Circulation Journal is published monthly in English and publishes scientific and state-of-the-art clinical articles aimed at improving human health in general and contributing to the treatment and prevention of cardiovascular diseases in particular. The journal is published on the official website (https://e-kcj.org). It is indexed in PubMed, PubMed Central, Science Citation Index Expanded (SCIE, Web of Science), Scopus, EMBASE, Chemical Abstracts Service (CAS), Google Scholar, KoreaMed, KoreaMed Synapse and KoMCI, and easily available to wide international researchers
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信