Mohammad Joudaki, Arash Azizi, Sahel Bazarnoei, Shirin Lawaf
{"title":"GLUMA脱敏剂和低强度980 nm二极管激光对自粘树脂水泥(RelyX U200)固化烤瓷冠金属框架固位的影响。","authors":"Mohammad Joudaki, Arash Azizi, Sahel Bazarnoei, Shirin Lawaf","doi":"10.34172/jlms.2025.03","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction:</b> Sometimes, dentinal tubules are exposed to the oral cavity during the preparation of vital teeth for crowns, and patients show various signs of tooth hypersensitivity. Some treatments have been suggested for dental hypersensitivity after tooth preparation, such as low-level diode laser (980 nm) and GLUMA desensitizer. The pretreatment of dentin with desensitizers may affect retention. The aim of this study was to ascertain the effects of the 980nm Diode laser and GLUMA Desensitizer on the retention of the metal frames cemented by self-adhesive resin cement (RelyX U200). <b>Methods:</b> Thirty intact permanent maxillary first premolars were used in this study. After preparing teeth with 0.5 to 0.7 finishing line above CEJ, casting full metal crowns with a 5-diameter ring on the occlusal surface was done. Then the samples were divided into 3 groups: (1) Control Group (n=10), (2) 980 nm diode laser (n=10), and (3) GLUMA desensitizer (n=10). Frames were cemented with self-adhesive resin cement (RelyX U200) and the bond strength was measured by universal testing machine. Data were analyzed by ANOVA and Tukey post hoc tests in SPSS version 25 (<i>P</i><0.05). <b>Results:</b> Frame retention in the 980 nm diode laser group (40.90±27.07N) was significantly lower than the control group (138.17±40.81 N) and the GLUMA desensitizer group (318.59±56.31N) (<i>P</i><0.05), and frame retention in the GLUMA Desensitizer group was significantly higher than the other groups (<i>P</i><0.05). <b>Conclusion:</b> The GLUMA desensitizer has a positive effect and the 980 nm diode laser has a negative effect on the retention of frames cemented by self-adhesive resin cement (RelyX U200).</p>","PeriodicalId":16224,"journal":{"name":"Journal of lasers in medical sciences","volume":"16 ","pages":"e3"},"PeriodicalIF":1.4000,"publicationDate":"2025-01-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12049577/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effects of GLUMA Desensitizer and Low-Level 980 nm Diode Laser on the Retention of the Metal Frames of the PFM Crowns Cemented by Self-adhesive Resin Cement (RelyX U200).\",\"authors\":\"Mohammad Joudaki, Arash Azizi, Sahel Bazarnoei, Shirin Lawaf\",\"doi\":\"10.34172/jlms.2025.03\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Introduction:</b> Sometimes, dentinal tubules are exposed to the oral cavity during the preparation of vital teeth for crowns, and patients show various signs of tooth hypersensitivity. Some treatments have been suggested for dental hypersensitivity after tooth preparation, such as low-level diode laser (980 nm) and GLUMA desensitizer. The pretreatment of dentin with desensitizers may affect retention. The aim of this study was to ascertain the effects of the 980nm Diode laser and GLUMA Desensitizer on the retention of the metal frames cemented by self-adhesive resin cement (RelyX U200). <b>Methods:</b> Thirty intact permanent maxillary first premolars were used in this study. After preparing teeth with 0.5 to 0.7 finishing line above CEJ, casting full metal crowns with a 5-diameter ring on the occlusal surface was done. Then the samples were divided into 3 groups: (1) Control Group (n=10), (2) 980 nm diode laser (n=10), and (3) GLUMA desensitizer (n=10). Frames were cemented with self-adhesive resin cement (RelyX U200) and the bond strength was measured by universal testing machine. Data were analyzed by ANOVA and Tukey post hoc tests in SPSS version 25 (<i>P</i><0.05). <b>Results:</b> Frame retention in the 980 nm diode laser group (40.90±27.07N) was significantly lower than the control group (138.17±40.81 N) and the GLUMA desensitizer group (318.59±56.31N) (<i>P</i><0.05), and frame retention in the GLUMA Desensitizer group was significantly higher than the other groups (<i>P</i><0.05). <b>Conclusion:</b> The GLUMA desensitizer has a positive effect and the 980 nm diode laser has a negative effect on the retention of frames cemented by self-adhesive resin cement (RelyX U200).</p>\",\"PeriodicalId\":16224,\"journal\":{\"name\":\"Journal of lasers in medical sciences\",\"volume\":\"16 \",\"pages\":\"e3\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2025-01-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12049577/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of lasers in medical sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.34172/jlms.2025.03\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of lasers in medical sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34172/jlms.2025.03","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Effects of GLUMA Desensitizer and Low-Level 980 nm Diode Laser on the Retention of the Metal Frames of the PFM Crowns Cemented by Self-adhesive Resin Cement (RelyX U200).
Introduction: Sometimes, dentinal tubules are exposed to the oral cavity during the preparation of vital teeth for crowns, and patients show various signs of tooth hypersensitivity. Some treatments have been suggested for dental hypersensitivity after tooth preparation, such as low-level diode laser (980 nm) and GLUMA desensitizer. The pretreatment of dentin with desensitizers may affect retention. The aim of this study was to ascertain the effects of the 980nm Diode laser and GLUMA Desensitizer on the retention of the metal frames cemented by self-adhesive resin cement (RelyX U200). Methods: Thirty intact permanent maxillary first premolars were used in this study. After preparing teeth with 0.5 to 0.7 finishing line above CEJ, casting full metal crowns with a 5-diameter ring on the occlusal surface was done. Then the samples were divided into 3 groups: (1) Control Group (n=10), (2) 980 nm diode laser (n=10), and (3) GLUMA desensitizer (n=10). Frames were cemented with self-adhesive resin cement (RelyX U200) and the bond strength was measured by universal testing machine. Data were analyzed by ANOVA and Tukey post hoc tests in SPSS version 25 (P<0.05). Results: Frame retention in the 980 nm diode laser group (40.90±27.07N) was significantly lower than the control group (138.17±40.81 N) and the GLUMA desensitizer group (318.59±56.31N) (P<0.05), and frame retention in the GLUMA Desensitizer group was significantly higher than the other groups (P<0.05). Conclusion: The GLUMA desensitizer has a positive effect and the 980 nm diode laser has a negative effect on the retention of frames cemented by self-adhesive resin cement (RelyX U200).
期刊介绍:
The "Journal of Lasers in Medical Sciences " is a scientific quarterly publication of the Laser Application in Medical Sciences Research Center, Shahid Beheshti University of Medical Sciences. This journal received a scientific and research rank from the national medical publication committee. This Journal accepts original papers, review articles, case reports, brief reports, case series, photo assays, letters to the editor, and commentaries in the field of laser, or light in any fields of medicine such as the following medical specialties: -Dermatology -General and Vascular Surgery -Oncology -Cardiology -Dentistry -Urology -Rehabilitation -Ophthalmology -Otorhinolaryngology -Gynecology & Obstetrics -Internal Medicine -Orthopedics -Neurosurgery -Radiology -Pain Medicine (Algology) -Basic Sciences (Stem cell, Cellular and Molecular application and physic)