GLUMA脱敏剂和低强度980 nm二极管激光对自粘树脂水泥(RelyX U200)固化烤瓷冠金属框架固位的影响。

IF 1.4 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Journal of lasers in medical sciences Pub Date : 2025-01-21 eCollection Date: 2025-01-01 DOI:10.34172/jlms.2025.03
Mohammad Joudaki, Arash Azizi, Sahel Bazarnoei, Shirin Lawaf
{"title":"GLUMA脱敏剂和低强度980 nm二极管激光对自粘树脂水泥(RelyX U200)固化烤瓷冠金属框架固位的影响。","authors":"Mohammad Joudaki, Arash Azizi, Sahel Bazarnoei, Shirin Lawaf","doi":"10.34172/jlms.2025.03","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction:</b> Sometimes, dentinal tubules are exposed to the oral cavity during the preparation of vital teeth for crowns, and patients show various signs of tooth hypersensitivity. Some treatments have been suggested for dental hypersensitivity after tooth preparation, such as low-level diode laser (980 nm) and GLUMA desensitizer. The pretreatment of dentin with desensitizers may affect retention. The aim of this study was to ascertain the effects of the 980nm Diode laser and GLUMA Desensitizer on the retention of the metal frames cemented by self-adhesive resin cement (RelyX U200). <b>Methods:</b> Thirty intact permanent maxillary first premolars were used in this study. After preparing teeth with 0.5 to 0.7 finishing line above CEJ, casting full metal crowns with a 5-diameter ring on the occlusal surface was done. Then the samples were divided into 3 groups: (1) Control Group (n=10), (2) 980 nm diode laser (n=10), and (3) GLUMA desensitizer (n=10). Frames were cemented with self-adhesive resin cement (RelyX U200) and the bond strength was measured by universal testing machine. Data were analyzed by ANOVA and Tukey post hoc tests in SPSS version 25 (<i>P</i><0.05). <b>Results:</b> Frame retention in the 980 nm diode laser group (40.90±27.07N) was significantly lower than the control group (138.17±40.81 N) and the GLUMA desensitizer group (318.59±56.31N) (<i>P</i><0.05), and frame retention in the GLUMA Desensitizer group was significantly higher than the other groups (<i>P</i><0.05). <b>Conclusion:</b> The GLUMA desensitizer has a positive effect and the 980 nm diode laser has a negative effect on the retention of frames cemented by self-adhesive resin cement (RelyX U200).</p>","PeriodicalId":16224,"journal":{"name":"Journal of lasers in medical sciences","volume":"16 ","pages":"e3"},"PeriodicalIF":1.4000,"publicationDate":"2025-01-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12049577/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effects of GLUMA Desensitizer and Low-Level 980 nm Diode Laser on the Retention of the Metal Frames of the PFM Crowns Cemented by Self-adhesive Resin Cement (RelyX U200).\",\"authors\":\"Mohammad Joudaki, Arash Azizi, Sahel Bazarnoei, Shirin Lawaf\",\"doi\":\"10.34172/jlms.2025.03\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Introduction:</b> Sometimes, dentinal tubules are exposed to the oral cavity during the preparation of vital teeth for crowns, and patients show various signs of tooth hypersensitivity. Some treatments have been suggested for dental hypersensitivity after tooth preparation, such as low-level diode laser (980 nm) and GLUMA desensitizer. The pretreatment of dentin with desensitizers may affect retention. The aim of this study was to ascertain the effects of the 980nm Diode laser and GLUMA Desensitizer on the retention of the metal frames cemented by self-adhesive resin cement (RelyX U200). <b>Methods:</b> Thirty intact permanent maxillary first premolars were used in this study. After preparing teeth with 0.5 to 0.7 finishing line above CEJ, casting full metal crowns with a 5-diameter ring on the occlusal surface was done. Then the samples were divided into 3 groups: (1) Control Group (n=10), (2) 980 nm diode laser (n=10), and (3) GLUMA desensitizer (n=10). Frames were cemented with self-adhesive resin cement (RelyX U200) and the bond strength was measured by universal testing machine. Data were analyzed by ANOVA and Tukey post hoc tests in SPSS version 25 (<i>P</i><0.05). <b>Results:</b> Frame retention in the 980 nm diode laser group (40.90±27.07N) was significantly lower than the control group (138.17±40.81 N) and the GLUMA desensitizer group (318.59±56.31N) (<i>P</i><0.05), and frame retention in the GLUMA Desensitizer group was significantly higher than the other groups (<i>P</i><0.05). <b>Conclusion:</b> The GLUMA desensitizer has a positive effect and the 980 nm diode laser has a negative effect on the retention of frames cemented by self-adhesive resin cement (RelyX U200).</p>\",\"PeriodicalId\":16224,\"journal\":{\"name\":\"Journal of lasers in medical sciences\",\"volume\":\"16 \",\"pages\":\"e3\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2025-01-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12049577/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of lasers in medical sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.34172/jlms.2025.03\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of lasers in medical sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34172/jlms.2025.03","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

在预备牙冠过程中,有时牙本质小管暴露在口腔内,患者表现出各种牙齿过敏症状。对于预备牙后的牙敏反应,建议采用低能级二极管激光(980 nm)和GLUMA脱敏剂等治疗方法。用脱敏剂预处理牙本质会影响牙本质的固位。本研究的目的是确定980nm二极管激光和GLUMA脱敏剂对自粘树脂水泥(RelyX U200)粘接金属框架固位的影响。方法:选择30颗完整的恒颌第一前磨牙作为研究对象。在CEJ上方0.5 ~ 0.7终点线预备好牙后,在咬合面铸造5直径环的全金属冠。然后将样品分为3组:(1)对照组(n=10), (2) 980 nm二极管激光器(n=10), (3) GLUMA脱敏剂(n=10)。框架采用自粘树脂水泥(RelyX U200)进行胶结,并用万能试验机测定胶结强度。结果:980 nm二极管激光组(40.90±27.07N)显著低于对照组(138.17±40.81 N)和GLUMA脱敏剂组(318.59±56.31N) (ppp)。结论:GLUMA脱敏剂对自粘树脂水泥(RelyX U200)固化框架的固位有积极影响,980 nm二极管激光对自粘树脂水泥(RelyX U200)固化框架的固位有消极影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effects of GLUMA Desensitizer and Low-Level 980 nm Diode Laser on the Retention of the Metal Frames of the PFM Crowns Cemented by Self-adhesive Resin Cement (RelyX U200).

Introduction: Sometimes, dentinal tubules are exposed to the oral cavity during the preparation of vital teeth for crowns, and patients show various signs of tooth hypersensitivity. Some treatments have been suggested for dental hypersensitivity after tooth preparation, such as low-level diode laser (980 nm) and GLUMA desensitizer. The pretreatment of dentin with desensitizers may affect retention. The aim of this study was to ascertain the effects of the 980nm Diode laser and GLUMA Desensitizer on the retention of the metal frames cemented by self-adhesive resin cement (RelyX U200). Methods: Thirty intact permanent maxillary first premolars were used in this study. After preparing teeth with 0.5 to 0.7 finishing line above CEJ, casting full metal crowns with a 5-diameter ring on the occlusal surface was done. Then the samples were divided into 3 groups: (1) Control Group (n=10), (2) 980 nm diode laser (n=10), and (3) GLUMA desensitizer (n=10). Frames were cemented with self-adhesive resin cement (RelyX U200) and the bond strength was measured by universal testing machine. Data were analyzed by ANOVA and Tukey post hoc tests in SPSS version 25 (P<0.05). Results: Frame retention in the 980 nm diode laser group (40.90±27.07N) was significantly lower than the control group (138.17±40.81 N) and the GLUMA desensitizer group (318.59±56.31N) (P<0.05), and frame retention in the GLUMA Desensitizer group was significantly higher than the other groups (P<0.05). Conclusion: The GLUMA desensitizer has a positive effect and the 980 nm diode laser has a negative effect on the retention of frames cemented by self-adhesive resin cement (RelyX U200).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of lasers in medical sciences
Journal of lasers in medical sciences RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
3.00
自引率
13.30%
发文量
24
期刊介绍: The "Journal of Lasers in Medical Sciences " is a scientific quarterly publication of the Laser Application in Medical Sciences Research Center, Shahid Beheshti University of Medical Sciences. This journal received a scientific and research rank from the national medical publication committee. This Journal accepts original papers, review articles, case reports, brief reports, case series, photo assays, letters to the editor, and commentaries in the field of laser, or light in any fields of medicine such as the following medical specialties: -Dermatology -General and Vascular Surgery -Oncology -Cardiology -Dentistry -Urology -Rehabilitation -Ophthalmology -Otorhinolaryngology -Gynecology & Obstetrics -Internal Medicine -Orthopedics -Neurosurgery -Radiology -Pain Medicine (Algology) -Basic Sciences (Stem cell, Cellular and Molecular application and physic)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信