超高分辨率光子计数检测器肺部计算机断层扫描重建核优化。

IF 1.3 4区 医学 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Adrienn Tóth, Jordan H Chamberlin, Carter D Smith, Dhruw Maisuria, Aaron M McGuire, U Joseph Schoepf, Jim O'Doherty, Reginald F Munden, Jeremy Burt, Dhiraj Baruah, Ismail M Kabakus
{"title":"超高分辨率光子计数检测器肺部计算机断层扫描重建核优化。","authors":"Adrienn Tóth, Jordan H Chamberlin, Carter D Smith, Dhruw Maisuria, Aaron M McGuire, U Joseph Schoepf, Jim O'Doherty, Reginald F Munden, Jeremy Burt, Dhiraj Baruah, Ismail M Kabakus","doi":"10.1097/RCT.0000000000001694","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The latest generation of computed tomography (CT) systems based on photon-counting detector promises significant improvements in several clinical applications, including chest imaging.</p><p><strong>Purpose: </strong>The aim of the study is to evaluate the image quality of ultra-high-resolution (UHR) photon-counting detector CT (PCD-CT) of the lung using four sharp reconstruction kernels.</p><p><strong>Material and methods: </strong>This retrospective study included 25 patients (11 women and 14 men; median age, 71 years) who underwent unenhanced chest CT from April to May 2023. Images were acquired in UHR mode on a clinical dual-source PCD-CT scanner and reconstructed with four sharp kernels (Bl64, Br76, Br84, Br96). Quantitative image analysis included the measurement of image noise, and the calculation of signal-to-noise ratio, and contrast-to-noise ratio. Two radiologists independently rated the images on a 5-point Likert scale for image sharpness, image noise, overall image quality, and airway details. The 4 image sets were compared pairwise in the statistical analysis.</p><p><strong>Results: </strong>Image noise was lowest for Br76 (74.16 ± 22.05, P  < 0.001). Signal-to-noise ratio was significantly higher in the Br76 images (13.34 ± 3.47), than in the other 3 image sets (all P  < 0.001). The Br76 images demonstrated the highest contrast-to-noise ratio among all reconstructions (1.54 ± 0.86, all P  < 0.001). Subjective image sharpness, image noise, overall image quality, and airway detail were best in the Br76 images (all P  < 0.001 to P  < 0.01, for both readers).</p><p><strong>Conclusions: </strong>The use of the Br76 reconstruction kernel provided the best quantitative and qualitative image quality for UHR PCD-CT of the lungs.</p>","PeriodicalId":15402,"journal":{"name":"Journal of Computer Assisted Tomography","volume":"49 3","pages":"456-461"},"PeriodicalIF":1.3000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reconstruction Kernel Optimization for Ultra-High-Resolution Photon-Counting Detector Computed Tomography of the Lung.\",\"authors\":\"Adrienn Tóth, Jordan H Chamberlin, Carter D Smith, Dhruw Maisuria, Aaron M McGuire, U Joseph Schoepf, Jim O'Doherty, Reginald F Munden, Jeremy Burt, Dhiraj Baruah, Ismail M Kabakus\",\"doi\":\"10.1097/RCT.0000000000001694\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The latest generation of computed tomography (CT) systems based on photon-counting detector promises significant improvements in several clinical applications, including chest imaging.</p><p><strong>Purpose: </strong>The aim of the study is to evaluate the image quality of ultra-high-resolution (UHR) photon-counting detector CT (PCD-CT) of the lung using four sharp reconstruction kernels.</p><p><strong>Material and methods: </strong>This retrospective study included 25 patients (11 women and 14 men; median age, 71 years) who underwent unenhanced chest CT from April to May 2023. Images were acquired in UHR mode on a clinical dual-source PCD-CT scanner and reconstructed with four sharp kernels (Bl64, Br76, Br84, Br96). Quantitative image analysis included the measurement of image noise, and the calculation of signal-to-noise ratio, and contrast-to-noise ratio. Two radiologists independently rated the images on a 5-point Likert scale for image sharpness, image noise, overall image quality, and airway details. The 4 image sets were compared pairwise in the statistical analysis.</p><p><strong>Results: </strong>Image noise was lowest for Br76 (74.16 ± 22.05, P  < 0.001). Signal-to-noise ratio was significantly higher in the Br76 images (13.34 ± 3.47), than in the other 3 image sets (all P  < 0.001). The Br76 images demonstrated the highest contrast-to-noise ratio among all reconstructions (1.54 ± 0.86, all P  < 0.001). Subjective image sharpness, image noise, overall image quality, and airway detail were best in the Br76 images (all P  < 0.001 to P  < 0.01, for both readers).</p><p><strong>Conclusions: </strong>The use of the Br76 reconstruction kernel provided the best quantitative and qualitative image quality for UHR PCD-CT of the lungs.</p>\",\"PeriodicalId\":15402,\"journal\":{\"name\":\"Journal of Computer Assisted Tomography\",\"volume\":\"49 3\",\"pages\":\"456-461\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2025-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Computer Assisted Tomography\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/RCT.0000000000001694\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/11/18 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Computer Assisted Tomography","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RCT.0000000000001694","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/18 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

背景:基于光子计数检测器的最新一代计算机断层扫描(CT)系统有望在包括胸部成像在内的几种临床应用中取得重大进展。目的:利用四种锐重建核对肺部超高分辨率光子计数CT (PCD-CT)图像质量进行评价。材料和方法:本回顾性研究纳入25例患者(女性11例,男性14例;中位年龄,71岁),于2023年4月至5月接受了未增强胸部CT。在临床双源PCD-CT扫描仪上以UHR模式获取图像,并使用四个尖锐核(Bl64, Br76, Br84, Br96)重建图像。定量图像分析包括图像噪声的测量、信噪比和比噪比的计算。两名放射科医生根据图像清晰度、图像噪声、整体图像质量和气道细节,以李克特5分制对图像进行独立评分。对4组图像进行两两比较统计分析。结果:Br76的图像噪声最低(74.16±22.05,P)。结论:使用Br76重建核为肺部UHR PCD-CT提供了最佳的定量和定性图像质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reconstruction Kernel Optimization for Ultra-High-Resolution Photon-Counting Detector Computed Tomography of the Lung.

Background: The latest generation of computed tomography (CT) systems based on photon-counting detector promises significant improvements in several clinical applications, including chest imaging.

Purpose: The aim of the study is to evaluate the image quality of ultra-high-resolution (UHR) photon-counting detector CT (PCD-CT) of the lung using four sharp reconstruction kernels.

Material and methods: This retrospective study included 25 patients (11 women and 14 men; median age, 71 years) who underwent unenhanced chest CT from April to May 2023. Images were acquired in UHR mode on a clinical dual-source PCD-CT scanner and reconstructed with four sharp kernels (Bl64, Br76, Br84, Br96). Quantitative image analysis included the measurement of image noise, and the calculation of signal-to-noise ratio, and contrast-to-noise ratio. Two radiologists independently rated the images on a 5-point Likert scale for image sharpness, image noise, overall image quality, and airway details. The 4 image sets were compared pairwise in the statistical analysis.

Results: Image noise was lowest for Br76 (74.16 ± 22.05, P  < 0.001). Signal-to-noise ratio was significantly higher in the Br76 images (13.34 ± 3.47), than in the other 3 image sets (all P  < 0.001). The Br76 images demonstrated the highest contrast-to-noise ratio among all reconstructions (1.54 ± 0.86, all P  < 0.001). Subjective image sharpness, image noise, overall image quality, and airway detail were best in the Br76 images (all P  < 0.001 to P  < 0.01, for both readers).

Conclusions: The use of the Br76 reconstruction kernel provided the best quantitative and qualitative image quality for UHR PCD-CT of the lungs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.50
自引率
0.00%
发文量
230
审稿时长
4-8 weeks
期刊介绍: The mission of Journal of Computer Assisted Tomography is to showcase the latest clinical and research developments in CT, MR, and closely related diagnostic techniques. We encourage submission of both original research and review articles that have immediate or promissory clinical applications. Topics of special interest include: 1) functional MR and CT of the brain and body; 2) advanced/innovative MRI techniques (diffusion, perfusion, rapid scanning); and 3) advanced/innovative CT techniques (perfusion, multi-energy, dose-reduction, and processing).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信