玻璃体切除术后角膜内滤过膜剥离及凹下注射治疗糖尿病黄斑水肿。

IF 1.4 4区 医学 Q3 OPHTHALMOLOGY
European Journal of Ophthalmology Pub Date : 2025-05-01 Epub Date: 2024-10-17 DOI:10.1177/11206721241290264
Zofia Nawrocka, Jerzy Nawrocki
{"title":"玻璃体切除术后角膜内滤过膜剥离及凹下注射治疗糖尿病黄斑水肿。","authors":"Zofia Nawrocka, Jerzy Nawrocki","doi":"10.1177/11206721241290264","DOIUrl":null,"url":null,"abstract":"<p><p>PurposeTo determine whether subretinal injections cause defects in the RPE that are visible on fundus autofluorescence (FAF).MethodsThis retrospective study analyzed twenty-six eyes after vitrectomy with ILM peeling and subretinal injection of balanced salt solution for diabetic macular edema (DME). FAF was performed before and 36 months after surgery. Four FAF patterns were distinguished: grade 1 -normal autofluorescence, grade 2 -one or more hyperautofluorescent spots, grade 3 -central increased autofluorescence, grade 4 -central decreased autofluorescence.ResultsVisual acuity improved from 0.18 to 0.26 Snellen (<i>p</i> = 0.03). Retinal thickness decreased (<i>p</i> = 0.01). The injection site would not be possible to spot on postoperative FAF without reviewing surgical videos. Grade 1 pattern was visible in 31% operated and 36% fellow eyes, Grade 2 pattern was observed in 11% operated and in 43% fellow eyes, Grade 3 pattern in 31% operated and in 14% fellow eyes and grade 4 pattern in 31% operated and in 14% fellow eyes.ConclusionNo abnormal FAF patterns were observed at the subretinal injection sites. ILM peeling likely decreases the pressure required to perform the injection and protects the RPE from iatrogenic damage. Anomalous autofluorescence patterns are most likely associated with long-standing disease.</p>","PeriodicalId":12000,"journal":{"name":"European Journal of Ophthalmology","volume":"35 3","pages":"1036-1043"},"PeriodicalIF":1.4000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fundus autofluorescence after vitrectomy with ILM peeling and subfoveal injection in diabetic macular edema.\",\"authors\":\"Zofia Nawrocka, Jerzy Nawrocki\",\"doi\":\"10.1177/11206721241290264\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>PurposeTo determine whether subretinal injections cause defects in the RPE that are visible on fundus autofluorescence (FAF).MethodsThis retrospective study analyzed twenty-six eyes after vitrectomy with ILM peeling and subretinal injection of balanced salt solution for diabetic macular edema (DME). FAF was performed before and 36 months after surgery. Four FAF patterns were distinguished: grade 1 -normal autofluorescence, grade 2 -one or more hyperautofluorescent spots, grade 3 -central increased autofluorescence, grade 4 -central decreased autofluorescence.ResultsVisual acuity improved from 0.18 to 0.26 Snellen (<i>p</i> = 0.03). Retinal thickness decreased (<i>p</i> = 0.01). The injection site would not be possible to spot on postoperative FAF without reviewing surgical videos. Grade 1 pattern was visible in 31% operated and 36% fellow eyes, Grade 2 pattern was observed in 11% operated and in 43% fellow eyes, Grade 3 pattern in 31% operated and in 14% fellow eyes and grade 4 pattern in 31% operated and in 14% fellow eyes.ConclusionNo abnormal FAF patterns were observed at the subretinal injection sites. ILM peeling likely decreases the pressure required to perform the injection and protects the RPE from iatrogenic damage. Anomalous autofluorescence patterns are most likely associated with long-standing disease.</p>\",\"PeriodicalId\":12000,\"journal\":{\"name\":\"European Journal of Ophthalmology\",\"volume\":\"35 3\",\"pages\":\"1036-1043\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2025-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/11206721241290264\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11206721241290264","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/17 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的观察视网膜下注射是否会引起眼底自身荧光(FAF)显示的RPE缺损。方法回顾性分析26只玻璃体切除术后视网膜下注射平衡盐溶液治疗糖尿病性黄斑水肿(DME)的病例。术前和术后36个月分别行FAF。FAF分为四种模式:1级-正常自体荧光,2级-一个或多个高度自体荧光斑点,3级-中心型自体荧光增强,4级-中心型自体荧光减弱。结果视力由0.18改善至0.26 (p = 0.03)。视网膜厚度降低(p = 0.01)。如果不回顾手术录像,就不可能在术后FAF上发现注射部位。31%的手术眼和36%的同伴眼可见1级模式,11%的手术眼和43%的同伴眼可见2级模式,31%的手术眼和14%的同伴眼可见3级模式,31%的手术眼和14%的同伴眼可见4级模式。结论视网膜下注射部位未见FAF异常。ILM剥离可能会降低进行注射所需的压力,并保护RPE免受医源性损伤。异常的自身荧光模式很可能与长期疾病有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fundus autofluorescence after vitrectomy with ILM peeling and subfoveal injection in diabetic macular edema.

PurposeTo determine whether subretinal injections cause defects in the RPE that are visible on fundus autofluorescence (FAF).MethodsThis retrospective study analyzed twenty-six eyes after vitrectomy with ILM peeling and subretinal injection of balanced salt solution for diabetic macular edema (DME). FAF was performed before and 36 months after surgery. Four FAF patterns were distinguished: grade 1 -normal autofluorescence, grade 2 -one or more hyperautofluorescent spots, grade 3 -central increased autofluorescence, grade 4 -central decreased autofluorescence.ResultsVisual acuity improved from 0.18 to 0.26 Snellen (p = 0.03). Retinal thickness decreased (p = 0.01). The injection site would not be possible to spot on postoperative FAF without reviewing surgical videos. Grade 1 pattern was visible in 31% operated and 36% fellow eyes, Grade 2 pattern was observed in 11% operated and in 43% fellow eyes, Grade 3 pattern in 31% operated and in 14% fellow eyes and grade 4 pattern in 31% operated and in 14% fellow eyes.ConclusionNo abnormal FAF patterns were observed at the subretinal injection sites. ILM peeling likely decreases the pressure required to perform the injection and protects the RPE from iatrogenic damage. Anomalous autofluorescence patterns are most likely associated with long-standing disease.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.60
自引率
0.00%
发文量
372
审稿时长
3-8 weeks
期刊介绍: The European Journal of Ophthalmology was founded in 1991 and is issued in print bi-monthly. It publishes only peer-reviewed original research reporting clinical observations and laboratory investigations with clinical relevance focusing on new diagnostic and surgical techniques, instrument and therapy updates, results of clinical trials and research findings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信