{"title":"evermin50依维莫司洗脱冠状动脉支架系统在原生冠状动脉病变患者中的安全性和有效性:单中心三年结果","authors":"Suresh V Patted","doi":"10.34172/jcvtr.025.33123","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The Evermine50<sup>TM</sup> (Meril Life Sciences Pvt. Ltd., India) is the world's thinnest strut (50 µm) featuring a biodegradable polymer-based Everolimus-eluting stent (EES) system. We present the 3-year safety and performance outcomes of Evermine50 EES.</p><p><strong>Methods: </strong>This was a prospective, post-marketing, single-center study of patients with native coronary artery lesions (CAL) in real-world settings. Patients with symptomatic ischemic heart disease due to <i>de novo</i> and in-stent restenotic lesions (lengths<44mm) in native coronary arteries with reference vessel diameters of 2.0 - 4.5 mm. and eligible for stenting procedure with percutaneous transluminal coronary angioplasty were included.</p><p><strong>Results: </strong>A total of 251 patients (mean age: 58.20 years) were enrolled, of which 48.2% had ST-elevation myocardial infarction and 31.5% had silent ischemia. The mean lesion length was 21.81±8.14 mm, and 70.3% of patients had pre-procedure Thrombolysis in Myocardial Infarction (TIMI) flow grade III. The average and stent length was recorded as 23.50±12.21 mm. In 98% of patients, post-procedural TIMI-III flow grade was achieved. The cumulative rate of major adverse cardiac events defined as composite of cardiac death, target vessel myocardial infarction, and clinically-driven target lesion revascularization (CD-TLR) at 1, 2, and 3 years were 1.59%, 3.58%, and 3.58%, respectively. The cumulative rates of CD-TLR remained constant at 0.79% from 1 to 3 years. There were no cases of stent thrombosis until 3 years.</p><p><strong>Conclusion: </strong>This study demonstrated favorable safety and performance of the ultrathin Evermine50 EES at 36 months in patients with native CAL.</p>","PeriodicalId":15207,"journal":{"name":"Journal of Cardiovascular and Thoracic Research","volume":"17 1","pages":"58-65"},"PeriodicalIF":1.2000,"publicationDate":"2025-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12068795/pdf/","citationCount":"0","resultStr":"{\"title\":\"Safety and efficacy of Evermine50 Everolimus-eluting coronary stent system in patients with native coronary artery lesions: Three-year outcomes from a single-center.\",\"authors\":\"Suresh V Patted\",\"doi\":\"10.34172/jcvtr.025.33123\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>The Evermine50<sup>TM</sup> (Meril Life Sciences Pvt. Ltd., India) is the world's thinnest strut (50 µm) featuring a biodegradable polymer-based Everolimus-eluting stent (EES) system. We present the 3-year safety and performance outcomes of Evermine50 EES.</p><p><strong>Methods: </strong>This was a prospective, post-marketing, single-center study of patients with native coronary artery lesions (CAL) in real-world settings. Patients with symptomatic ischemic heart disease due to <i>de novo</i> and in-stent restenotic lesions (lengths<44mm) in native coronary arteries with reference vessel diameters of 2.0 - 4.5 mm. and eligible for stenting procedure with percutaneous transluminal coronary angioplasty were included.</p><p><strong>Results: </strong>A total of 251 patients (mean age: 58.20 years) were enrolled, of which 48.2% had ST-elevation myocardial infarction and 31.5% had silent ischemia. The mean lesion length was 21.81±8.14 mm, and 70.3% of patients had pre-procedure Thrombolysis in Myocardial Infarction (TIMI) flow grade III. The average and stent length was recorded as 23.50±12.21 mm. In 98% of patients, post-procedural TIMI-III flow grade was achieved. The cumulative rate of major adverse cardiac events defined as composite of cardiac death, target vessel myocardial infarction, and clinically-driven target lesion revascularization (CD-TLR) at 1, 2, and 3 years were 1.59%, 3.58%, and 3.58%, respectively. The cumulative rates of CD-TLR remained constant at 0.79% from 1 to 3 years. There were no cases of stent thrombosis until 3 years.</p><p><strong>Conclusion: </strong>This study demonstrated favorable safety and performance of the ultrathin Evermine50 EES at 36 months in patients with native CAL.</p>\",\"PeriodicalId\":15207,\"journal\":{\"name\":\"Journal of Cardiovascular and Thoracic Research\",\"volume\":\"17 1\",\"pages\":\"58-65\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2025-03-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12068795/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Cardiovascular and Thoracic Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.34172/jcvtr.025.33123\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/3/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular and Thoracic Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34172/jcvtr.025.33123","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Safety and efficacy of Evermine50 Everolimus-eluting coronary stent system in patients with native coronary artery lesions: Three-year outcomes from a single-center.
Introduction: The Evermine50TM (Meril Life Sciences Pvt. Ltd., India) is the world's thinnest strut (50 µm) featuring a biodegradable polymer-based Everolimus-eluting stent (EES) system. We present the 3-year safety and performance outcomes of Evermine50 EES.
Methods: This was a prospective, post-marketing, single-center study of patients with native coronary artery lesions (CAL) in real-world settings. Patients with symptomatic ischemic heart disease due to de novo and in-stent restenotic lesions (lengths<44mm) in native coronary arteries with reference vessel diameters of 2.0 - 4.5 mm. and eligible for stenting procedure with percutaneous transluminal coronary angioplasty were included.
Results: A total of 251 patients (mean age: 58.20 years) were enrolled, of which 48.2% had ST-elevation myocardial infarction and 31.5% had silent ischemia. The mean lesion length was 21.81±8.14 mm, and 70.3% of patients had pre-procedure Thrombolysis in Myocardial Infarction (TIMI) flow grade III. The average and stent length was recorded as 23.50±12.21 mm. In 98% of patients, post-procedural TIMI-III flow grade was achieved. The cumulative rate of major adverse cardiac events defined as composite of cardiac death, target vessel myocardial infarction, and clinically-driven target lesion revascularization (CD-TLR) at 1, 2, and 3 years were 1.59%, 3.58%, and 3.58%, respectively. The cumulative rates of CD-TLR remained constant at 0.79% from 1 to 3 years. There were no cases of stent thrombosis until 3 years.
Conclusion: This study demonstrated favorable safety and performance of the ultrathin Evermine50 EES at 36 months in patients with native CAL.