数字技术与传统技术构建下颌种植固位覆盖义齿的比较。

IF 2.6 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Abd Elsalam Awad Ali, Ahmed Habib, Mohamed Shady
{"title":"数字技术与传统技术构建下颌种植固位覆盖义齿的比较。","authors":"Abd Elsalam Awad Ali, Ahmed Habib, Mohamed Shady","doi":"10.1186/s12903-025-05918-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study aimed to evaluate two different construction techniques (conventional and 3D-printed techniques) for two implant-retained complete mandibular overdentures regarding mechanical wear of the occlusal surface using 3D digital analysis and occlusion force distribution using the digital occlusal analysis system (Occlusense).</p><p><strong>Methods: </strong>Twenty patients were selected for this study from the prosthetic department, Faculty of Dentistry, Mansoura University. Each patient received two implants in the mandibular canine areas with locator attachments to retain the overdentures. According to the overdenture construction technique, all patients were randomly divided into two equal groups: the conventional heat polymerized overdenture group and the 3D-printed overdenture group. The mandibular overdentures were compared and evaluated immediately and after 12 months of insertion regarding mechanical wear of the occlusal surface using 3D digital analysis and occlusal force distribution using a digital occlusal analysis system (Occlusense).</p><p><strong>Results: </strong>3d printed group showed significantly higher occlusal surface wear than conventional group after twelve months (T12) with a p value ≤ 0.05. 3d printed group showed significantly more occlusal force distribution than conventional group with a p value ≤ 0.05. Also, there was a significant difference in occlusal force distribution with advance of time for each group, with a p value ≤ 0.05 level of significance.</p><p><strong>Conclusion: </strong>Within the limitations of this study, it was shown that implant overdentures constructed by 3D-printing techniques offer a promising results in distribution of occlusal forces for achieving occlusal equilibration. However, in term of wear resistance more developments need to be done to improve material properties.</p><p><strong>Trial registration: </strong>The study was approved by the local ethical committee of the Faculty of Dentistry, Mansoura University (No. A02060922) (6/9/2022) and retrospectively registered at ClinicalTrials.gov (ClinicalTrials.gov Identifier NCT06139003) (16/11/2023).</p>","PeriodicalId":9072,"journal":{"name":"BMC Oral Health","volume":"25 1","pages":"686"},"PeriodicalIF":2.6000,"publicationDate":"2025-05-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12054292/pdf/","citationCount":"0","resultStr":"{\"title\":\"Digital versus conventional techniques for construction of mandibular implant retained overdenture.\",\"authors\":\"Abd Elsalam Awad Ali, Ahmed Habib, Mohamed Shady\",\"doi\":\"10.1186/s12903-025-05918-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>This study aimed to evaluate two different construction techniques (conventional and 3D-printed techniques) for two implant-retained complete mandibular overdentures regarding mechanical wear of the occlusal surface using 3D digital analysis and occlusion force distribution using the digital occlusal analysis system (Occlusense).</p><p><strong>Methods: </strong>Twenty patients were selected for this study from the prosthetic department, Faculty of Dentistry, Mansoura University. Each patient received two implants in the mandibular canine areas with locator attachments to retain the overdentures. According to the overdenture construction technique, all patients were randomly divided into two equal groups: the conventional heat polymerized overdenture group and the 3D-printed overdenture group. The mandibular overdentures were compared and evaluated immediately and after 12 months of insertion regarding mechanical wear of the occlusal surface using 3D digital analysis and occlusal force distribution using a digital occlusal analysis system (Occlusense).</p><p><strong>Results: </strong>3d printed group showed significantly higher occlusal surface wear than conventional group after twelve months (T12) with a p value ≤ 0.05. 3d printed group showed significantly more occlusal force distribution than conventional group with a p value ≤ 0.05. Also, there was a significant difference in occlusal force distribution with advance of time for each group, with a p value ≤ 0.05 level of significance.</p><p><strong>Conclusion: </strong>Within the limitations of this study, it was shown that implant overdentures constructed by 3D-printing techniques offer a promising results in distribution of occlusal forces for achieving occlusal equilibration. However, in term of wear resistance more developments need to be done to improve material properties.</p><p><strong>Trial registration: </strong>The study was approved by the local ethical committee of the Faculty of Dentistry, Mansoura University (No. A02060922) (6/9/2022) and retrospectively registered at ClinicalTrials.gov (ClinicalTrials.gov Identifier NCT06139003) (16/11/2023).</p>\",\"PeriodicalId\":9072,\"journal\":{\"name\":\"BMC Oral Health\",\"volume\":\"25 1\",\"pages\":\"686\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2025-05-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12054292/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BMC Oral Health\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12903-025-05918-2\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Oral Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12903-025-05918-2","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

背景:本研究旨在通过三维数字分析和数字咬合分析系统(Occlusense)的咬合力分布来评估两种不同的种植下颌覆盖义齿建造技术(传统技术和3D打印技术)对咬合面机械磨损的影响。方法:选取曼苏拉大学口腔医学院修复科患者20例进行研究。每位患者在下颌犬齿区接受两颗种植体,并附有定位附件以保留覆盖义齿。根据覆盖义齿的构建技术,将所有患者随机分为两组:常规热聚合覆盖义齿组和3d打印覆盖义齿组。采用三维数字分析和数字咬合分析系统(Occlusense)的咬合力分布,比较和评估下颌覆盖义齿即刻和置入12个月后的咬合面机械磨损。结果:3d打印组在12个月(T12)后咬合面磨损明显高于常规组,p值≤0.05。3d打印组的咬合力分布明显高于常规组,p值≤0.05。各组牙合力分布随时间的推移差异有统计学意义,p值≤0.05。结论:在本研究的局限性内,通过3d打印技术构建的种植覆盖义齿在实现咬合平衡的咬合力分布方面提供了有希望的结果。然而,在耐磨性方面,需要做更多的发展来改善材料的性能。试验注册:该研究已获得曼苏拉大学牙科学院当地伦理委员会(No. 6)批准。A02060922)(6/9/2022),并在ClinicalTrials.gov (ClinicalTrials.gov标识号NCT06139003)(16/11/2023)回顾性注册。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Digital versus conventional techniques for construction of mandibular implant retained overdenture.

Background: This study aimed to evaluate two different construction techniques (conventional and 3D-printed techniques) for two implant-retained complete mandibular overdentures regarding mechanical wear of the occlusal surface using 3D digital analysis and occlusion force distribution using the digital occlusal analysis system (Occlusense).

Methods: Twenty patients were selected for this study from the prosthetic department, Faculty of Dentistry, Mansoura University. Each patient received two implants in the mandibular canine areas with locator attachments to retain the overdentures. According to the overdenture construction technique, all patients were randomly divided into two equal groups: the conventional heat polymerized overdenture group and the 3D-printed overdenture group. The mandibular overdentures were compared and evaluated immediately and after 12 months of insertion regarding mechanical wear of the occlusal surface using 3D digital analysis and occlusal force distribution using a digital occlusal analysis system (Occlusense).

Results: 3d printed group showed significantly higher occlusal surface wear than conventional group after twelve months (T12) with a p value ≤ 0.05. 3d printed group showed significantly more occlusal force distribution than conventional group with a p value ≤ 0.05. Also, there was a significant difference in occlusal force distribution with advance of time for each group, with a p value ≤ 0.05 level of significance.

Conclusion: Within the limitations of this study, it was shown that implant overdentures constructed by 3D-printing techniques offer a promising results in distribution of occlusal forces for achieving occlusal equilibration. However, in term of wear resistance more developments need to be done to improve material properties.

Trial registration: The study was approved by the local ethical committee of the Faculty of Dentistry, Mansoura University (No. A02060922) (6/9/2022) and retrospectively registered at ClinicalTrials.gov (ClinicalTrials.gov Identifier NCT06139003) (16/11/2023).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
BMC Oral Health
BMC Oral Health DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.90
自引率
6.90%
发文量
481
审稿时长
6-12 weeks
期刊介绍: BMC Oral Health is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of disorders of the mouth, teeth and gums, as well as related molecular genetics, pathophysiology, and epidemiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信