采用增强多层螺旋ct结合磁共振成像技术对结肠癌患者进行分期及术前评估。

IF 1 4区 医学 Q4 ENGINEERING, BIOMEDICAL
Cong Liang, Ying Wu, Limei Wang, Junfang Bai, Dan Wang, Fei Zhao
{"title":"采用增强多层螺旋ct结合磁共振成像技术对结肠癌患者进行分期及术前评估。","authors":"Cong Liang, Ying Wu, Limei Wang, Junfang Bai, Dan Wang, Fei Zhao","doi":"10.1177/09592989251335125","DOIUrl":null,"url":null,"abstract":"<p><p>BackgroundColon cancer (CC) refers to malignant tumor of the digestive tract worldwide and is also among the cancers with high mortality rates.ObjectiveThe aim of this work was to evaluate the diagnostic performance of multislice spiral CT (MSCT), magnetic resonance imaging (MRI), and MSCT + MRI in different stages of colon cancer (CC) (T1-T2, T3, T4). This work compared the differences in sensitivity (<i>Sen</i>), specificity (<i>Spe</i>), accuracy (Acc), and area under the curve (AUC) values among these methods and explored the optimal diagnostic strategy.MethodsA total of 120 patients with CC confirmed by pathological biopsy and 30 individuals suspected of CC but without detected tumors (as controls) were selected. All subjects underwent MSCT, MRI, and combined MSCT + MRI examinations. Statistical analyses of <i>Sen</i>, <i>Spe</i>, <i>Acc</i>, and AUC values were performed.ResultsIn the T1-T2 stage, MSCT had a <i>Sen</i> of 85.2%, <i>Acc</i> of 86.8%, and an AUC value of 0.878; MRI had a <i>Spe</i> of 91.0%, <i>Sen</i> of 81.6%, and an AUC value of 0.865; the combined MSCT + MRI examination had a <i>Sen</i> of 90.6% and an AUC of 0.903. In the T3 stage, MRI had a significantly higher <i>Sen</i> (91.7%) than MSCT (80.0%), with an AUC of 0.887, while the combined MSCT + MRI examination had a <i>Sen</i> of 98.3% and an AUC of 0.942. In the T4 stage, the combined MSCT + MRI examination performed the best, with a <i>Sen</i> of 100% and an AUC of 0.933, and compared with MSCT or MRI alone, the differences were statistically significant (<i>P </i>< 0.05).ConclusionMSCT and MRI each have their own advantages in the diagnosis of different stages of CC. MSCT is suitable for initial screening in the T1-T2 stage, while MRI is more effective in assessing tumor invasiveness in the T3 and higher stages. The combined MSCT + MRI examination can provide more comprehensive diagnostic information, especially in the T4 stage, where it shows the highest <i>Sen</i> and <i>Acc</i>. Selecting the appropriate examination method based on the patient's specific condition and staging needs is of great significance in improving the diagnostic <i>Acc</i> of CC.</p>","PeriodicalId":9109,"journal":{"name":"Bio-medical materials and engineering","volume":" ","pages":"9592989251335125"},"PeriodicalIF":1.0000,"publicationDate":"2025-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Adoption of enhanced multislice spiral computed tomography combined with magnetic resonance imaging in staging and preoperative assessment of colon cancer patients.\",\"authors\":\"Cong Liang, Ying Wu, Limei Wang, Junfang Bai, Dan Wang, Fei Zhao\",\"doi\":\"10.1177/09592989251335125\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>BackgroundColon cancer (CC) refers to malignant tumor of the digestive tract worldwide and is also among the cancers with high mortality rates.ObjectiveThe aim of this work was to evaluate the diagnostic performance of multislice spiral CT (MSCT), magnetic resonance imaging (MRI), and MSCT + MRI in different stages of colon cancer (CC) (T1-T2, T3, T4). This work compared the differences in sensitivity (<i>Sen</i>), specificity (<i>Spe</i>), accuracy (Acc), and area under the curve (AUC) values among these methods and explored the optimal diagnostic strategy.MethodsA total of 120 patients with CC confirmed by pathological biopsy and 30 individuals suspected of CC but without detected tumors (as controls) were selected. All subjects underwent MSCT, MRI, and combined MSCT + MRI examinations. Statistical analyses of <i>Sen</i>, <i>Spe</i>, <i>Acc</i>, and AUC values were performed.ResultsIn the T1-T2 stage, MSCT had a <i>Sen</i> of 85.2%, <i>Acc</i> of 86.8%, and an AUC value of 0.878; MRI had a <i>Spe</i> of 91.0%, <i>Sen</i> of 81.6%, and an AUC value of 0.865; the combined MSCT + MRI examination had a <i>Sen</i> of 90.6% and an AUC of 0.903. In the T3 stage, MRI had a significantly higher <i>Sen</i> (91.7%) than MSCT (80.0%), with an AUC of 0.887, while the combined MSCT + MRI examination had a <i>Sen</i> of 98.3% and an AUC of 0.942. In the T4 stage, the combined MSCT + MRI examination performed the best, with a <i>Sen</i> of 100% and an AUC of 0.933, and compared with MSCT or MRI alone, the differences were statistically significant (<i>P </i>< 0.05).ConclusionMSCT and MRI each have their own advantages in the diagnosis of different stages of CC. MSCT is suitable for initial screening in the T1-T2 stage, while MRI is more effective in assessing tumor invasiveness in the T3 and higher stages. The combined MSCT + MRI examination can provide more comprehensive diagnostic information, especially in the T4 stage, where it shows the highest <i>Sen</i> and <i>Acc</i>. Selecting the appropriate examination method based on the patient's specific condition and staging needs is of great significance in improving the diagnostic <i>Acc</i> of CC.</p>\",\"PeriodicalId\":9109,\"journal\":{\"name\":\"Bio-medical materials and engineering\",\"volume\":\" \",\"pages\":\"9592989251335125\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2025-04-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bio-medical materials and engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/09592989251335125\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bio-medical materials and engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/09592989251335125","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

结肠癌(colon cancer, CC)是一种世界性的消化道恶性肿瘤,也是死亡率较高的癌症之一。目的探讨多层螺旋CT (MSCT)、磁共振成像(MRI)及MSCT + MRI对不同分期结肠癌(T1-T2、T3、T4)的诊断价值。本工作比较了这些方法在敏感性(Sen)、特异性(Spe)、准确性(Acc)和曲线下面积(AUC)值方面的差异,并探讨了最佳诊断策略。方法选取经病理活检证实的CC患者120例和疑似CC但未发现肿瘤的患者30例作为对照。所有受试者均接受了MSCT、MRI和MSCT + MRI联合检查。对Sen、Spe、Acc和AUC值进行统计分析。结果t1 ~ t2期MSCT的Sen为85.2%,Acc为86.8%,AUC值为0.878;MRI的Spe为91.0%,Sen为81.6%,AUC值为0.865;MSCT + MRI联合检查的Sen为90.6%,AUC为0.903。T3期MRI Sen(91.7%)明显高于MSCT (80.0%), AUC为0.887,而MSCT + MRI联合检查Sen为98.3%,AUC为0.942。在T4期,MSCT + MRI联合检查效果最好,Sen为100%,AUC为0.933,与单独MSCT或MRI比较,差异有统计学意义(P Sen和Acc。根据患者的具体情况和分期需要选择合适的检查方法,对提高CC的诊断Acc具有重要意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Adoption of enhanced multislice spiral computed tomography combined with magnetic resonance imaging in staging and preoperative assessment of colon cancer patients.

BackgroundColon cancer (CC) refers to malignant tumor of the digestive tract worldwide and is also among the cancers with high mortality rates.ObjectiveThe aim of this work was to evaluate the diagnostic performance of multislice spiral CT (MSCT), magnetic resonance imaging (MRI), and MSCT + MRI in different stages of colon cancer (CC) (T1-T2, T3, T4). This work compared the differences in sensitivity (Sen), specificity (Spe), accuracy (Acc), and area under the curve (AUC) values among these methods and explored the optimal diagnostic strategy.MethodsA total of 120 patients with CC confirmed by pathological biopsy and 30 individuals suspected of CC but without detected tumors (as controls) were selected. All subjects underwent MSCT, MRI, and combined MSCT + MRI examinations. Statistical analyses of Sen, Spe, Acc, and AUC values were performed.ResultsIn the T1-T2 stage, MSCT had a Sen of 85.2%, Acc of 86.8%, and an AUC value of 0.878; MRI had a Spe of 91.0%, Sen of 81.6%, and an AUC value of 0.865; the combined MSCT + MRI examination had a Sen of 90.6% and an AUC of 0.903. In the T3 stage, MRI had a significantly higher Sen (91.7%) than MSCT (80.0%), with an AUC of 0.887, while the combined MSCT + MRI examination had a Sen of 98.3% and an AUC of 0.942. In the T4 stage, the combined MSCT + MRI examination performed the best, with a Sen of 100% and an AUC of 0.933, and compared with MSCT or MRI alone, the differences were statistically significant (P < 0.05).ConclusionMSCT and MRI each have their own advantages in the diagnosis of different stages of CC. MSCT is suitable for initial screening in the T1-T2 stage, while MRI is more effective in assessing tumor invasiveness in the T3 and higher stages. The combined MSCT + MRI examination can provide more comprehensive diagnostic information, especially in the T4 stage, where it shows the highest Sen and Acc. Selecting the appropriate examination method based on the patient's specific condition and staging needs is of great significance in improving the diagnostic Acc of CC.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Bio-medical materials and engineering
Bio-medical materials and engineering 工程技术-材料科学:生物材料
CiteScore
1.80
自引率
0.00%
发文量
73
审稿时长
6 months
期刊介绍: The aim of Bio-Medical Materials and Engineering is to promote the welfare of humans and to help them keep healthy. This international journal is an interdisciplinary journal that publishes original research papers, review articles and brief notes on materials and engineering for biological and medical systems. Articles in this peer-reviewed journal cover a wide range of topics, including, but not limited to: Engineering as applied to improving diagnosis, therapy, and prevention of disease and injury, and better substitutes for damaged or disabled human organs; Studies of biomaterial interactions with the human body, bio-compatibility, interfacial and interaction problems; Biomechanical behavior under biological and/or medical conditions; Mechanical and biological properties of membrane biomaterials; Cellular and tissue engineering, physiological, biophysical, biochemical bioengineering aspects; Implant failure fields and degradation of implants. Biomimetics engineering and materials including system analysis as supporter for aged people and as rehabilitation; Bioengineering and materials technology as applied to the decontamination against environmental problems; Biosensors, bioreactors, bioprocess instrumentation and control system; Application to food engineering; Standardization problems on biomaterials and related products; Assessment of reliability and safety of biomedical materials and man-machine systems; and Product liability of biomaterials and related products.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信