修复后成人法洛四联症的4D与2D相对比非增强MRI血流评估。

IF 4.7 2区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
European Radiology Pub Date : 2025-10-01 Epub Date: 2025-04-17 DOI:10.1007/s00330-025-11542-z
Jean Alfred François Champollion, Thomas Senage, Lara Marteau, Jean-Michel Serfaty, Patrice Guerin, Jean-Nicolas Dacher, Karine Warin-Fresse
{"title":"修复后成人法洛四联症的4D与2D相对比非增强MRI血流评估。","authors":"Jean Alfred François Champollion, Thomas Senage, Lara Marteau, Jean-Michel Serfaty, Patrice Guerin, Jean-Nicolas Dacher, Karine Warin-Fresse","doi":"10.1007/s00330-025-11542-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To describe the reliability of quantitative MRI analysis of flows using 4D-PC (Phase Contrast) compared to 2D-PC flow, without contrast agents.</p><p><strong>Materials and methods: </strong>The study was conducted at one centre in a retrospective manner from 2021 to 2023. Eligible patients were adults with repaired Tetralogy of Fallot (rToF) whose follow-up MRI protocol included 4D-PC and 2D-PC, without contrast agent. Assessment involved quantitative measurement of aortic and pulmonary flows on both 4D and 2D. Student's T was used for comparisons of means and Lin's concordance correlation coefficient agreement (CCC). A 2nd observer was hired.</p><p><strong>Results: </strong>Twenty-six patients were included (50% men, median age of 27 [20; 34]). Scanning mean time was 13 min for 4D and 47 min for non-4D part. Systematic underestimation in pulmonary regurgitation fraction (-10 ± 15%, p = 0.02) and backward volume (-13 ± 18 mL, p = 0.02) was found. Agreement on regurgitant fraction was strong for pulmonary (CCC = 0.75 [0.58-0.86], p < 0.001) and aortic (CCC = 0.91 [0.81-0.95], p < 0.001). Inter-observer showed overall strong results.</p><p><strong>Conclusion: </strong>Non-enhanced 4D-PC flow MRI seems to be a reliable method of quantitative flow in rToF patients, but it may underestimate pulmonary regurgitation.</p><p><strong>Key points: </strong>Question 4D-MRI stands out as an innovative tool for evaluating flows in adults with repaired Tetralogy of Fallot during follow-up. Findings 4D phase-contrast imaging without the use of contrast agents exhibits robust results and high reproducibility. Clinical relevance 4D-MR is presented as an accurate and versatile tool of cardiac exploration that could improve patient comfort. Minimizing brain gadolinium exposure and reducing scanning time are key objectives of non-enhanced 4D-MR.</p>","PeriodicalId":12076,"journal":{"name":"European Radiology","volume":" ","pages":"6313-6322"},"PeriodicalIF":4.7000,"publicationDate":"2025-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Non-enhanced MRI flow evaluation using 4D versus 2D phase-contrast in repaired Tetralogy of Fallot adults.\",\"authors\":\"Jean Alfred François Champollion, Thomas Senage, Lara Marteau, Jean-Michel Serfaty, Patrice Guerin, Jean-Nicolas Dacher, Karine Warin-Fresse\",\"doi\":\"10.1007/s00330-025-11542-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To describe the reliability of quantitative MRI analysis of flows using 4D-PC (Phase Contrast) compared to 2D-PC flow, without contrast agents.</p><p><strong>Materials and methods: </strong>The study was conducted at one centre in a retrospective manner from 2021 to 2023. Eligible patients were adults with repaired Tetralogy of Fallot (rToF) whose follow-up MRI protocol included 4D-PC and 2D-PC, without contrast agent. Assessment involved quantitative measurement of aortic and pulmonary flows on both 4D and 2D. Student's T was used for comparisons of means and Lin's concordance correlation coefficient agreement (CCC). A 2nd observer was hired.</p><p><strong>Results: </strong>Twenty-six patients were included (50% men, median age of 27 [20; 34]). Scanning mean time was 13 min for 4D and 47 min for non-4D part. Systematic underestimation in pulmonary regurgitation fraction (-10 ± 15%, p = 0.02) and backward volume (-13 ± 18 mL, p = 0.02) was found. Agreement on regurgitant fraction was strong for pulmonary (CCC = 0.75 [0.58-0.86], p < 0.001) and aortic (CCC = 0.91 [0.81-0.95], p < 0.001). Inter-observer showed overall strong results.</p><p><strong>Conclusion: </strong>Non-enhanced 4D-PC flow MRI seems to be a reliable method of quantitative flow in rToF patients, but it may underestimate pulmonary regurgitation.</p><p><strong>Key points: </strong>Question 4D-MRI stands out as an innovative tool for evaluating flows in adults with repaired Tetralogy of Fallot during follow-up. Findings 4D phase-contrast imaging without the use of contrast agents exhibits robust results and high reproducibility. Clinical relevance 4D-MR is presented as an accurate and versatile tool of cardiac exploration that could improve patient comfort. Minimizing brain gadolinium exposure and reducing scanning time are key objectives of non-enhanced 4D-MR.</p>\",\"PeriodicalId\":12076,\"journal\":{\"name\":\"European Radiology\",\"volume\":\" \",\"pages\":\"6313-6322\"},\"PeriodicalIF\":4.7000,\"publicationDate\":\"2025-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00330-025-11542-z\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/4/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00330-025-11542-z","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/4/17 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:描述在不使用造影剂的情况下,与2D-PC流相比,使用4D-PC(相位对比)对血流进行定量MRI分析的可靠性。材料和方法:本研究于2021年至2023年在一个中心进行回顾性研究。符合条件的患者为成人修复法洛四联症(rToF),随访MRI方案包括4D-PC和2D-PC,未使用造影剂。评估包括在4D和2D上定量测量主动脉和肺血流。均值与Lin’s一致性相关系数一致性(CCC)的比较采用Student’s T。又雇了一名观察员。结果:纳入26例患者(50%为男性,中位年龄27岁;34])。4D扫描平均时间为13 min,非4D扫描平均时间为47 min。系统性低估肺返流分数(-10±15%,p = 0.02)和回流容积(-13±18 mL, p = 0.02)。结论:非增强4D-PC血流MRI似乎是rToF患者定量血流的可靠方法,但可能低估了肺反流。4D-MRI作为一种创新的工具,在随访期间评估成人修复法洛四联症患者的血流。结果不使用造影剂的4D相衬成像结果可靠,重现性高。临床相关性4D-MR是一种准确和通用的心脏探查工具,可以提高患者的舒适度。减少脑部钆暴露和缩短扫描时间是非增强4D-MR的关键目标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Non-enhanced MRI flow evaluation using 4D versus 2D phase-contrast in repaired Tetralogy of Fallot adults.

Objectives: To describe the reliability of quantitative MRI analysis of flows using 4D-PC (Phase Contrast) compared to 2D-PC flow, without contrast agents.

Materials and methods: The study was conducted at one centre in a retrospective manner from 2021 to 2023. Eligible patients were adults with repaired Tetralogy of Fallot (rToF) whose follow-up MRI protocol included 4D-PC and 2D-PC, without contrast agent. Assessment involved quantitative measurement of aortic and pulmonary flows on both 4D and 2D. Student's T was used for comparisons of means and Lin's concordance correlation coefficient agreement (CCC). A 2nd observer was hired.

Results: Twenty-six patients were included (50% men, median age of 27 [20; 34]). Scanning mean time was 13 min for 4D and 47 min for non-4D part. Systematic underestimation in pulmonary regurgitation fraction (-10 ± 15%, p = 0.02) and backward volume (-13 ± 18 mL, p = 0.02) was found. Agreement on regurgitant fraction was strong for pulmonary (CCC = 0.75 [0.58-0.86], p < 0.001) and aortic (CCC = 0.91 [0.81-0.95], p < 0.001). Inter-observer showed overall strong results.

Conclusion: Non-enhanced 4D-PC flow MRI seems to be a reliable method of quantitative flow in rToF patients, but it may underestimate pulmonary regurgitation.

Key points: Question 4D-MRI stands out as an innovative tool for evaluating flows in adults with repaired Tetralogy of Fallot during follow-up. Findings 4D phase-contrast imaging without the use of contrast agents exhibits robust results and high reproducibility. Clinical relevance 4D-MR is presented as an accurate and versatile tool of cardiac exploration that could improve patient comfort. Minimizing brain gadolinium exposure and reducing scanning time are key objectives of non-enhanced 4D-MR.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Radiology
European Radiology 医学-核医学
CiteScore
11.60
自引率
8.50%
发文量
874
审稿时长
2-4 weeks
期刊介绍: European Radiology (ER) continuously updates scientific knowledge in radiology by publication of strong original articles and state-of-the-art reviews written by leading radiologists. A well balanced combination of review articles, original papers, short communications from European radiological congresses and information on society matters makes ER an indispensable source for current information in this field. This is the Journal of the European Society of Radiology, and the official journal of a number of societies. From 2004-2008 supplements to European Radiology were published under its companion, European Radiology Supplements, ISSN 1613-3749.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信