Jong Hwa Jun, Seung Pil Bang, Kyu Young Shim, Alexander C Lieu, Natalie A Afshari
{"title":"四法兰巩膜内固定过程中触觉设计、通过方向和法兰间距离对人工晶状体位置的影响。","authors":"Jong Hwa Jun, Seung Pil Bang, Kyu Young Shim, Alexander C Lieu, Natalie A Afshari","doi":"10.1080/02713683.2025.2495218","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>We aimed to investigate the effect of haptic design, direction of suture passage, and distance between flanges on the haptic-iris distance after four-flanged scleral fixation of a single-piece intraocular lens with four eyelets.</p><p><strong>Methods: </strong>After marking the 3 and 9 o'clock positions on the limbus, each 26-G needle was positioned 2.0 mm posterior to the limbus and passed 2.0, 3.0, and 4.0 mm away from the markings at 3 o'clock and 9 o'clock, respectively. We passed each end of a 5-0 polypropylene suture anteroposteriorly or posteroanteriorly through two unilateral eyelets. The haptic-iris distance was evaluated using anterior-segment optical coherence tomography.</p><p><strong>Results: </strong>Passing the suture through the eyelets in the posteroanterior direction yielded a wider haptic-iris distance than that achieved by passing the suture in the anteroposterior direction (<i>p</i> < 0.001, respectively). A wider distance between the polypropylene flanges correlated with reduced distortion of haptic structures. Fixation of the Akreos AO with a 4.0-mm suture spacing induced a wider haptic-iris distance (<i>p</i> < 0.001).</p><p><strong>Conclusion: </strong>Passing sutures through the eyelet in the posteroanterior direction during intrascleral fixation proved to be more effective in securing a sufficient haptic-iris distance. A wider distance between flanges was beneficial in preventing structural distortion of the haptic and ensuring a proper distance between the haptic and iris.</p>","PeriodicalId":10782,"journal":{"name":"Current Eye Research","volume":" ","pages":"1-8"},"PeriodicalIF":1.7000,"publicationDate":"2025-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Haptic Design, Passing Direction, and Inter-Flange Distance on the Position of the Intraocular Lens during 4-Flanged Intrascleral Fixation.\",\"authors\":\"Jong Hwa Jun, Seung Pil Bang, Kyu Young Shim, Alexander C Lieu, Natalie A Afshari\",\"doi\":\"10.1080/02713683.2025.2495218\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>We aimed to investigate the effect of haptic design, direction of suture passage, and distance between flanges on the haptic-iris distance after four-flanged scleral fixation of a single-piece intraocular lens with four eyelets.</p><p><strong>Methods: </strong>After marking the 3 and 9 o'clock positions on the limbus, each 26-G needle was positioned 2.0 mm posterior to the limbus and passed 2.0, 3.0, and 4.0 mm away from the markings at 3 o'clock and 9 o'clock, respectively. We passed each end of a 5-0 polypropylene suture anteroposteriorly or posteroanteriorly through two unilateral eyelets. The haptic-iris distance was evaluated using anterior-segment optical coherence tomography.</p><p><strong>Results: </strong>Passing the suture through the eyelets in the posteroanterior direction yielded a wider haptic-iris distance than that achieved by passing the suture in the anteroposterior direction (<i>p</i> < 0.001, respectively). A wider distance between the polypropylene flanges correlated with reduced distortion of haptic structures. Fixation of the Akreos AO with a 4.0-mm suture spacing induced a wider haptic-iris distance (<i>p</i> < 0.001).</p><p><strong>Conclusion: </strong>Passing sutures through the eyelet in the posteroanterior direction during intrascleral fixation proved to be more effective in securing a sufficient haptic-iris distance. A wider distance between flanges was beneficial in preventing structural distortion of the haptic and ensuring a proper distance between the haptic and iris.</p>\",\"PeriodicalId\":10782,\"journal\":{\"name\":\"Current Eye Research\",\"volume\":\" \",\"pages\":\"1-8\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2025-05-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Eye Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/02713683.2025.2495218\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Eye Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/02713683.2025.2495218","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Effect of Haptic Design, Passing Direction, and Inter-Flange Distance on the Position of the Intraocular Lens during 4-Flanged Intrascleral Fixation.
Purpose: We aimed to investigate the effect of haptic design, direction of suture passage, and distance between flanges on the haptic-iris distance after four-flanged scleral fixation of a single-piece intraocular lens with four eyelets.
Methods: After marking the 3 and 9 o'clock positions on the limbus, each 26-G needle was positioned 2.0 mm posterior to the limbus and passed 2.0, 3.0, and 4.0 mm away from the markings at 3 o'clock and 9 o'clock, respectively. We passed each end of a 5-0 polypropylene suture anteroposteriorly or posteroanteriorly through two unilateral eyelets. The haptic-iris distance was evaluated using anterior-segment optical coherence tomography.
Results: Passing the suture through the eyelets in the posteroanterior direction yielded a wider haptic-iris distance than that achieved by passing the suture in the anteroposterior direction (p < 0.001, respectively). A wider distance between the polypropylene flanges correlated with reduced distortion of haptic structures. Fixation of the Akreos AO with a 4.0-mm suture spacing induced a wider haptic-iris distance (p < 0.001).
Conclusion: Passing sutures through the eyelet in the posteroanterior direction during intrascleral fixation proved to be more effective in securing a sufficient haptic-iris distance. A wider distance between flanges was beneficial in preventing structural distortion of the haptic and ensuring a proper distance between the haptic and iris.
期刊介绍:
The principal aim of Current Eye Research is to provide rapid publication of full papers, short communications and mini-reviews, all high quality. Current Eye Research publishes articles encompassing all the areas of eye research. Subject areas include the following: clinical research, anatomy, physiology, biophysics, biochemistry, pharmacology, developmental biology, microbiology and immunology.