高效液相色谱-质谱联用法测定大鼠血浆中禾甲苷和异禾甲苷的含量

IF 1.8 4区 医学 Q4 BIOCHEMICAL RESEARCH METHODS
Jianbo Li, Runrun Wang, Mengmeng Shao, Yongxi Jin, Saiya Chen, Xianqin Wang, Fang Chen
{"title":"高效液相色谱-质谱联用法测定大鼠血浆中禾甲苷和异禾甲苷的含量","authors":"Jianbo Li,&nbsp;Runrun Wang,&nbsp;Mengmeng Shao,&nbsp;Yongxi Jin,&nbsp;Saiya Chen,&nbsp;Xianqin Wang,&nbsp;Fang Chen","doi":"10.1002/bmc.70106","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>To evaluate the pharmacokinetics, absolute bioavailability, and plasma concentrations of schaftoside and isoschaftoside in rats, an UPLC-MS/MS method was employed. For sample preparation, plasma proteins were precipitated using chilled methanol. The separation was achieved on a UPLC HSS T3 column with a mobile phase consisting of methanol and water (with 0.1% formic acid in water), at a flow rate of 0.4 mL/min. Detection was performed using electrospray ionization (ESI) in positive ion mode, coupled with multiple reaction monitoring (MRM) for quantitative analysis. Rats received oral doses of schaftoside (1 mg/kg) and isoschaftoside (5 mg/kg), and the pharmacokinetic profiles of both compounds were compared. The calibration curve for the method demonstrated excellent linearity within the concentration range of 1–2000 ng/mL, with correlation coefficients (<i>r</i> values) exceeding 0.99. Following intravenous and oral administration, significant differences were observed in the AUC<sub>(0–t)</sub> between schaftoside and isoschaftoside, whereas their half-lives (t<sub>1/2</sub>) remained comparable. The absolute bioavailability of schaftoside and isoschaftoside in rat plasma was determined to be 0.95% and 0.22%, respectively.</p>\n </div>","PeriodicalId":8861,"journal":{"name":"Biomedical Chromatography","volume":"39 6","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determination of Schaftoside and Isoschaftoside in Rat Plasma Utilizing UPLC-MS/MS\",\"authors\":\"Jianbo Li,&nbsp;Runrun Wang,&nbsp;Mengmeng Shao,&nbsp;Yongxi Jin,&nbsp;Saiya Chen,&nbsp;Xianqin Wang,&nbsp;Fang Chen\",\"doi\":\"10.1002/bmc.70106\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n <p>To evaluate the pharmacokinetics, absolute bioavailability, and plasma concentrations of schaftoside and isoschaftoside in rats, an UPLC-MS/MS method was employed. For sample preparation, plasma proteins were precipitated using chilled methanol. The separation was achieved on a UPLC HSS T3 column with a mobile phase consisting of methanol and water (with 0.1% formic acid in water), at a flow rate of 0.4 mL/min. Detection was performed using electrospray ionization (ESI) in positive ion mode, coupled with multiple reaction monitoring (MRM) for quantitative analysis. Rats received oral doses of schaftoside (1 mg/kg) and isoschaftoside (5 mg/kg), and the pharmacokinetic profiles of both compounds were compared. The calibration curve for the method demonstrated excellent linearity within the concentration range of 1–2000 ng/mL, with correlation coefficients (<i>r</i> values) exceeding 0.99. Following intravenous and oral administration, significant differences were observed in the AUC<sub>(0–t)</sub> between schaftoside and isoschaftoside, whereas their half-lives (t<sub>1/2</sub>) remained comparable. The absolute bioavailability of schaftoside and isoschaftoside in rat plasma was determined to be 0.95% and 0.22%, respectively.</p>\\n </div>\",\"PeriodicalId\":8861,\"journal\":{\"name\":\"Biomedical Chromatography\",\"volume\":\"39 6\",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2025-05-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical Chromatography\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/bmc.70106\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Chromatography","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/bmc.70106","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

采用超高效液相色谱-质谱联用法(UPLC-MS/MS)评价禾甲苷和异禾甲苷在大鼠体内的药动学、绝对生物利用度和血药浓度。样品制备时,血浆蛋白用冷冻甲醇沉淀。采用UPLC HSS T3色谱柱进行分离,流动相为甲醇和水(水中含有0.1%甲酸),流速为0.4 mL/min。采用正离子模式电喷雾电离(ESI)进行检测,结合多反应监测(MRM)进行定量分析。大鼠分别口服1 mg/kg和5 mg/kg的麦草苷和异麦草苷,比较两种化合物的药代动力学特征。该方法的校准曲线在1 ~ 2000 ng/mL浓度范围内线性良好,相关系数(r值)均大于0.99。在静脉和口服给药后,观察到谷草苷和异谷草苷的AUC(0-t)有显著差异,而它们的半衰期(t1/2)保持可比性。测定了沙棘草苷和异沙棘草苷在大鼠血浆中的绝对生物利用度分别为0.95%和0.22%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Determination of Schaftoside and Isoschaftoside in Rat Plasma Utilizing UPLC-MS/MS

To evaluate the pharmacokinetics, absolute bioavailability, and plasma concentrations of schaftoside and isoschaftoside in rats, an UPLC-MS/MS method was employed. For sample preparation, plasma proteins were precipitated using chilled methanol. The separation was achieved on a UPLC HSS T3 column with a mobile phase consisting of methanol and water (with 0.1% formic acid in water), at a flow rate of 0.4 mL/min. Detection was performed using electrospray ionization (ESI) in positive ion mode, coupled with multiple reaction monitoring (MRM) for quantitative analysis. Rats received oral doses of schaftoside (1 mg/kg) and isoschaftoside (5 mg/kg), and the pharmacokinetic profiles of both compounds were compared. The calibration curve for the method demonstrated excellent linearity within the concentration range of 1–2000 ng/mL, with correlation coefficients (r values) exceeding 0.99. Following intravenous and oral administration, significant differences were observed in the AUC(0–t) between schaftoside and isoschaftoside, whereas their half-lives (t1/2) remained comparable. The absolute bioavailability of schaftoside and isoschaftoside in rat plasma was determined to be 0.95% and 0.22%, respectively.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biomedical Chromatography
Biomedical Chromatography 生物-分析化学
CiteScore
3.60
自引率
5.60%
发文量
268
审稿时长
2.3 months
期刊介绍: Biomedical Chromatography is devoted to the publication of original papers on the applications of chromatography and allied techniques in the biological and medical sciences. Research papers and review articles cover the methods and techniques relevant to the separation, identification and determination of substances in biochemistry, biotechnology, molecular biology, cell biology, clinical chemistry, pharmacology and related disciplines. These include the analysis of body fluids, cells and tissues, purification of biologically important compounds, pharmaco-kinetics and sequencing methods using HPLC, GC, HPLC-MS, TLC, paper chromatography, affinity chromatography, gel filtration, electrophoresis and related techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信