为应对COVID-19大流行,通过改变行为改善酒店场地通风

Simon De-Ville , Sophie Pott , Chantelle Wood , Zhangjie Peng , M. Zaeem Farooq , Giota Blouchou , Alisha Suhag , Edward Murphy , E. Abigail Hathway
{"title":"为应对COVID-19大流行,通过改变行为改善酒店场地通风","authors":"Simon De-Ville ,&nbsp;Sophie Pott ,&nbsp;Chantelle Wood ,&nbsp;Zhangjie Peng ,&nbsp;M. Zaeem Farooq ,&nbsp;Giota Blouchou ,&nbsp;Alisha Suhag ,&nbsp;Edward Murphy ,&nbsp;E. Abigail Hathway","doi":"10.1016/j.indenv.2025.100097","DOIUrl":null,"url":null,"abstract":"<div><div>The COVID-19 pandemic highlighted the importance of good ventilation in hospitality venues, given its role in reducing virus transmission. Small-scale hospitality venues (&lt;50 employees) employ 98 % of staff in the UK hospitality sector. However, little is known about the current state of ventilation in these venues, the barriers to more effective ventilation, and whether behaviour change strategies can improve ventilation performance. This formed the aims of the current research. This work was divided into three phases: Phase 1 explored the current performance of ventilation in hospitality venues and the barriers to more effective ventilation; Phase 2 led to the co-creation of a behaviour change intervention consisting of guidance material and provision of a CO<sub>2</sub> monitor; and Phase 3 piloted the intervention, evaluating changes in behaviour and ventilation performance, in addition to assessing user acceptability of the intervention. Ventilation performance was identified to be below recommended standards in most participating venues. Business owners stated they were not able to improve ventilation due to a lack of clear guidance, lack of funds to upgrade systems, limited authority over building infrastructure, and competing priorities. In these businesses, customer comfort, atmosphere, noise control, and security were given greater importance than improving ventilation. The introduction of a guidance document and CO<sub>2</sub> sensors to monitor ventilation performance saw 3 of 6 venues increase ventilation actions such as window/door opening and/or the switching on of wall mounted fans. Following the intervention, business owners expressed an increased likelihood of purchasing air cleaners, or mechanical ventilation systems. However, their likelihood of purchasing CO<sub>2</sub> monitors decreased. The guidance is advised to be used alongside spot check CO<sub>2</sub> monitoring during periods of high occupancy.</div></div>","PeriodicalId":100665,"journal":{"name":"Indoor Environments","volume":"2 2","pages":"Article 100097"},"PeriodicalIF":0.0000,"publicationDate":"2025-05-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Improving hospitality venue ventilation via behavioural change as a response to the COVID-19 pandemic\",\"authors\":\"Simon De-Ville ,&nbsp;Sophie Pott ,&nbsp;Chantelle Wood ,&nbsp;Zhangjie Peng ,&nbsp;M. Zaeem Farooq ,&nbsp;Giota Blouchou ,&nbsp;Alisha Suhag ,&nbsp;Edward Murphy ,&nbsp;E. Abigail Hathway\",\"doi\":\"10.1016/j.indenv.2025.100097\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The COVID-19 pandemic highlighted the importance of good ventilation in hospitality venues, given its role in reducing virus transmission. Small-scale hospitality venues (&lt;50 employees) employ 98 % of staff in the UK hospitality sector. However, little is known about the current state of ventilation in these venues, the barriers to more effective ventilation, and whether behaviour change strategies can improve ventilation performance. This formed the aims of the current research. This work was divided into three phases: Phase 1 explored the current performance of ventilation in hospitality venues and the barriers to more effective ventilation; Phase 2 led to the co-creation of a behaviour change intervention consisting of guidance material and provision of a CO<sub>2</sub> monitor; and Phase 3 piloted the intervention, evaluating changes in behaviour and ventilation performance, in addition to assessing user acceptability of the intervention. Ventilation performance was identified to be below recommended standards in most participating venues. Business owners stated they were not able to improve ventilation due to a lack of clear guidance, lack of funds to upgrade systems, limited authority over building infrastructure, and competing priorities. In these businesses, customer comfort, atmosphere, noise control, and security were given greater importance than improving ventilation. The introduction of a guidance document and CO<sub>2</sub> sensors to monitor ventilation performance saw 3 of 6 venues increase ventilation actions such as window/door opening and/or the switching on of wall mounted fans. Following the intervention, business owners expressed an increased likelihood of purchasing air cleaners, or mechanical ventilation systems. However, their likelihood of purchasing CO<sub>2</sub> monitors decreased. The guidance is advised to be used alongside spot check CO<sub>2</sub> monitoring during periods of high occupancy.</div></div>\",\"PeriodicalId\":100665,\"journal\":{\"name\":\"Indoor Environments\",\"volume\":\"2 2\",\"pages\":\"Article 100097\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-05-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indoor Environments\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2950362025000268\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indoor Environments","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2950362025000268","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

2019冠状病毒病大流行凸显了接待场所良好通风的重要性,因为它可以减少病毒传播。小型接待场所(50名员工)雇用了英国接待部门98% %的员工。然而,人们对这些场馆的通风现状、更有效通风的障碍以及行为改变策略是否能改善通风性能知之甚少。这就形成了本研究的目的。这项工作分为三个阶段:第一阶段探索酒店场所通风的现状和更有效通风的障碍;第二阶段是共同制定一项行为改变干预措施,包括指导材料和提供二氧化碳监测器;第三阶段试验干预措施,评估行为和通风性能的变化,以及评估用户对干预措施的可接受性。大多数参与活动的场地的通风性能均低于建议标准。企业主表示,由于缺乏明确的指导,缺乏升级系统的资金,对建筑基础设施的权限有限,以及优先事项的竞争,他们无法改善通风。在这些企业中,顾客舒适度、氛围、噪音控制和安全性比改善通风更为重要。引入指导文件和二氧化碳传感器来监测通风性能,6个场馆中有3个增加了通风措施,如打开窗户/门和/或打开壁挂风扇。在干预之后,企业主表示购买空气净化器或机械通风系统的可能性增加了。然而,他们购买二氧化碳监测器的可能性降低了。建议该指南与高入住率期间的二氧化碳抽查监测一起使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Improving hospitality venue ventilation via behavioural change as a response to the COVID-19 pandemic
The COVID-19 pandemic highlighted the importance of good ventilation in hospitality venues, given its role in reducing virus transmission. Small-scale hospitality venues (<50 employees) employ 98 % of staff in the UK hospitality sector. However, little is known about the current state of ventilation in these venues, the barriers to more effective ventilation, and whether behaviour change strategies can improve ventilation performance. This formed the aims of the current research. This work was divided into three phases: Phase 1 explored the current performance of ventilation in hospitality venues and the barriers to more effective ventilation; Phase 2 led to the co-creation of a behaviour change intervention consisting of guidance material and provision of a CO2 monitor; and Phase 3 piloted the intervention, evaluating changes in behaviour and ventilation performance, in addition to assessing user acceptability of the intervention. Ventilation performance was identified to be below recommended standards in most participating venues. Business owners stated they were not able to improve ventilation due to a lack of clear guidance, lack of funds to upgrade systems, limited authority over building infrastructure, and competing priorities. In these businesses, customer comfort, atmosphere, noise control, and security were given greater importance than improving ventilation. The introduction of a guidance document and CO2 sensors to monitor ventilation performance saw 3 of 6 venues increase ventilation actions such as window/door opening and/or the switching on of wall mounted fans. Following the intervention, business owners expressed an increased likelihood of purchasing air cleaners, or mechanical ventilation systems. However, their likelihood of purchasing CO2 monitors decreased. The guidance is advised to be used alongside spot check CO2 monitoring during periods of high occupancy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信