{"title":"DxI 9000接入免疫分析分析仪上抗- hbc IgM检测的性能评价","authors":"Catherine Coignard , Claire Vincent , Veronique Lemée , Jean-Christophe Plantier , Jérémie Gautier , Françoise Leboulaire , Marc Turini , Gaiane Demirdjian , Magali Karagueuzian , Vanessa Roulet , Juliane Hey , Dan W. Rhodes","doi":"10.1016/j.diagmicrobio.2025.116862","DOIUrl":null,"url":null,"abstract":"<div><div>This study evaluated the diagnostic and analytical performances of the Access anti-HBc IgM assay (Access assay) for use on the DxI 9000 Access Immunoassay Analyzer. Prospectively and retrospectively collected samples were tested with Access and a comparator assay with use of a second comparator for discrepant resolution to determine final anti-HBc IgM sample status. Specificity of Access was 100.00 % (99.65 – 100.00 %) on 1,098 anti-HBc IgM negative blood donor samples, 100.00 % (98.74 – 100.00 %) on 300 anti-HBc IgM negative hospitalized patient samples and 94.08 % (89.45 – 96.75 %) on 169 anti-HBc IgM negative acute/recent and chronic HBV infected patient samples. Sensitivity was 100.00 % (98.42 – 100.00 %) on 239 anti-HBc IgM positive acute/recent and chronic HBV infected patient samples. Seroconversion panels showed mean first day of detection 3.2 days earlier with Access than with the comparator assay. Maximum reproducibility on positive samples was 8.6 % coefficient of variance (CV) and 0.048 S/CO standard deviation (SD) on negative samples.</div><div>The Access anti-HBc IgM assay demonstrated excellent diagnostic and analytical performances comparable to other current CE-marked anti-HBc IgM assays.</div></div>","PeriodicalId":11329,"journal":{"name":"Diagnostic microbiology and infectious disease","volume":"112 4","pages":"Article 116862"},"PeriodicalIF":2.1000,"publicationDate":"2025-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance evaluation of the access anti-HBc IgM Assay on the DxI 9000 access immunoassay analyzer\",\"authors\":\"Catherine Coignard , Claire Vincent , Veronique Lemée , Jean-Christophe Plantier , Jérémie Gautier , Françoise Leboulaire , Marc Turini , Gaiane Demirdjian , Magali Karagueuzian , Vanessa Roulet , Juliane Hey , Dan W. Rhodes\",\"doi\":\"10.1016/j.diagmicrobio.2025.116862\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>This study evaluated the diagnostic and analytical performances of the Access anti-HBc IgM assay (Access assay) for use on the DxI 9000 Access Immunoassay Analyzer. Prospectively and retrospectively collected samples were tested with Access and a comparator assay with use of a second comparator for discrepant resolution to determine final anti-HBc IgM sample status. Specificity of Access was 100.00 % (99.65 – 100.00 %) on 1,098 anti-HBc IgM negative blood donor samples, 100.00 % (98.74 – 100.00 %) on 300 anti-HBc IgM negative hospitalized patient samples and 94.08 % (89.45 – 96.75 %) on 169 anti-HBc IgM negative acute/recent and chronic HBV infected patient samples. Sensitivity was 100.00 % (98.42 – 100.00 %) on 239 anti-HBc IgM positive acute/recent and chronic HBV infected patient samples. Seroconversion panels showed mean first day of detection 3.2 days earlier with Access than with the comparator assay. Maximum reproducibility on positive samples was 8.6 % coefficient of variance (CV) and 0.048 S/CO standard deviation (SD) on negative samples.</div><div>The Access anti-HBc IgM assay demonstrated excellent diagnostic and analytical performances comparable to other current CE-marked anti-HBc IgM assays.</div></div>\",\"PeriodicalId\":11329,\"journal\":{\"name\":\"Diagnostic microbiology and infectious disease\",\"volume\":\"112 4\",\"pages\":\"Article 116862\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2025-04-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diagnostic microbiology and infectious disease\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0732889325001853\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INFECTIOUS DISEASES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostic microbiology and infectious disease","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0732889325001853","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
Performance evaluation of the access anti-HBc IgM Assay on the DxI 9000 access immunoassay analyzer
This study evaluated the diagnostic and analytical performances of the Access anti-HBc IgM assay (Access assay) for use on the DxI 9000 Access Immunoassay Analyzer. Prospectively and retrospectively collected samples were tested with Access and a comparator assay with use of a second comparator for discrepant resolution to determine final anti-HBc IgM sample status. Specificity of Access was 100.00 % (99.65 – 100.00 %) on 1,098 anti-HBc IgM negative blood donor samples, 100.00 % (98.74 – 100.00 %) on 300 anti-HBc IgM negative hospitalized patient samples and 94.08 % (89.45 – 96.75 %) on 169 anti-HBc IgM negative acute/recent and chronic HBV infected patient samples. Sensitivity was 100.00 % (98.42 – 100.00 %) on 239 anti-HBc IgM positive acute/recent and chronic HBV infected patient samples. Seroconversion panels showed mean first day of detection 3.2 days earlier with Access than with the comparator assay. Maximum reproducibility on positive samples was 8.6 % coefficient of variance (CV) and 0.048 S/CO standard deviation (SD) on negative samples.
The Access anti-HBc IgM assay demonstrated excellent diagnostic and analytical performances comparable to other current CE-marked anti-HBc IgM assays.
期刊介绍:
Diagnostic Microbiology and Infectious Disease keeps you informed of the latest developments in clinical microbiology and the diagnosis and treatment of infectious diseases. Packed with rigorously peer-reviewed articles and studies in bacteriology, immunology, immunoserology, infectious diseases, mycology, parasitology, and virology, the journal examines new procedures, unusual cases, controversial issues, and important new literature. Diagnostic Microbiology and Infectious Disease distinguished independent editorial board, consisting of experts from many medical specialties, ensures you extensive and authoritative coverage.