{"title":"使用测试时间适应的实时自监督超声图像增强用于复杂的肩袖撕裂诊断","authors":"Haeyun Lee;Kyungsu Lee;Jong Pil Yoon;Jihun Kim;Jun-Young Kim","doi":"10.1109/LSP.2025.3557754","DOIUrl":null,"url":null,"abstract":"Medical ultrasound imaging is a key diagnostic tool across various fields, with computer-aided diagnosis systems benefiting from advances in deep learning. However, its lower resolution and artifacts pose challenges, particularly for non-specialists. The simultaneous acquisition of degraded and high-quality images is infeasible, limiting supervised learning approaches. Additionally, self-supervised and zero-shot methods require extensive processing time, conflicting with the real-time demands of ultrasound imaging. Therefore, to address the aforementioned issues, we propose real-time ultrasound image enhancement via a self-supervised learning technique and a test-time adaptation for sophisticated rotational cuff tear diagnosis. The proposed approach learns from other domain image datasets and performs self-supervised learning on an ultrasound image during inference for enhancement. Our approach not only demonstrated superior ultrasound image enhancement performance compared to other state-of-the-art methods but also achieved an 18% improvement in the RCT segmentation performance.","PeriodicalId":13154,"journal":{"name":"IEEE Signal Processing Letters","volume":"32 ","pages":"1635-1639"},"PeriodicalIF":3.2000,"publicationDate":"2025-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Real-Time Self-Supervised Ultrasound Image Enhancement Using Test-Time Adaptation for Sophisticated Rotator Cuff Tear Diagnosis\",\"authors\":\"Haeyun Lee;Kyungsu Lee;Jong Pil Yoon;Jihun Kim;Jun-Young Kim\",\"doi\":\"10.1109/LSP.2025.3557754\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Medical ultrasound imaging is a key diagnostic tool across various fields, with computer-aided diagnosis systems benefiting from advances in deep learning. However, its lower resolution and artifacts pose challenges, particularly for non-specialists. The simultaneous acquisition of degraded and high-quality images is infeasible, limiting supervised learning approaches. Additionally, self-supervised and zero-shot methods require extensive processing time, conflicting with the real-time demands of ultrasound imaging. Therefore, to address the aforementioned issues, we propose real-time ultrasound image enhancement via a self-supervised learning technique and a test-time adaptation for sophisticated rotational cuff tear diagnosis. The proposed approach learns from other domain image datasets and performs self-supervised learning on an ultrasound image during inference for enhancement. Our approach not only demonstrated superior ultrasound image enhancement performance compared to other state-of-the-art methods but also achieved an 18% improvement in the RCT segmentation performance.\",\"PeriodicalId\":13154,\"journal\":{\"name\":\"IEEE Signal Processing Letters\",\"volume\":\"32 \",\"pages\":\"1635-1639\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2025-04-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Signal Processing Letters\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10948347/\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Signal Processing Letters","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10948347/","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Real-Time Self-Supervised Ultrasound Image Enhancement Using Test-Time Adaptation for Sophisticated Rotator Cuff Tear Diagnosis
Medical ultrasound imaging is a key diagnostic tool across various fields, with computer-aided diagnosis systems benefiting from advances in deep learning. However, its lower resolution and artifacts pose challenges, particularly for non-specialists. The simultaneous acquisition of degraded and high-quality images is infeasible, limiting supervised learning approaches. Additionally, self-supervised and zero-shot methods require extensive processing time, conflicting with the real-time demands of ultrasound imaging. Therefore, to address the aforementioned issues, we propose real-time ultrasound image enhancement via a self-supervised learning technique and a test-time adaptation for sophisticated rotational cuff tear diagnosis. The proposed approach learns from other domain image datasets and performs self-supervised learning on an ultrasound image during inference for enhancement. Our approach not only demonstrated superior ultrasound image enhancement performance compared to other state-of-the-art methods but also achieved an 18% improvement in the RCT segmentation performance.
期刊介绍:
The IEEE Signal Processing Letters is a monthly, archival publication designed to provide rapid dissemination of original, cutting-edge ideas and timely, significant contributions in signal, image, speech, language and audio processing. Papers published in the Letters can be presented within one year of their appearance in signal processing conferences such as ICASSP, GlobalSIP and ICIP, and also in several workshop organized by the Signal Processing Society.