Xueru Zhang, Jiarong Guo, Wei Tang and Xinrui Duan
{"title":"一种新型鲁米诺相关羟基苯基苯并噻唑类似物化学发光探针,用于检测血迹的超高灵敏度","authors":"Xueru Zhang, Jiarong Guo, Wei Tang and Xinrui Duan","doi":"10.1039/D4NJ04283B","DOIUrl":null,"url":null,"abstract":"<p >Based on the chemical structure and luminescence mechanism of luminol, the synthesis of luminol analogues has been widely studied. However, luminol and its derived reagents are still suffering from some drawbacks, such as short luminescence time and weak intensity. Herein, we designed and synthesized a novel hydroxyphenyl benzothiazole-based phthalhydrazide derivative DAH-AMPH, which has a hydroxyphenyl benzothiazole structure as a strong fluorescent site and a cyclic phthalhydrazide structure as a chemiluminescence (CL) emitting site. DAH-AMPH exhibited excellent CL properties in the DAH-AMPH/UHP/hemin CL system for hemin detection with a wide linear range of 0.1 nM to 20.0 nM and low LOD of 3 pM. It exhibited good selectivity in bloodstain imaging on different substrate materials. The DAH-AMPH/UHP/hemin CL system represents a powerful tool for trace detection of bloodstains. Moreover, as a new CL substrate for HRP, DAH-AMPH showed high sensitivity (0.8 pg mL<small><sup>−1</sup></small> of LOD) in the DAH-AMPH/UHP/SPTZ/MORP/HRP CL system indicating bright prospects for the use of DAH-AMPH in heme-containing peroxidase detection.</p>","PeriodicalId":95,"journal":{"name":"New Journal of Chemistry","volume":" 17","pages":" 7019-7024"},"PeriodicalIF":2.5000,"publicationDate":"2025-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A novel luminol-related hydroxyphenyl benzothiazole analogue chemiluminescence probe with ultrahigh sensitivity for bloodstain detection†\",\"authors\":\"Xueru Zhang, Jiarong Guo, Wei Tang and Xinrui Duan\",\"doi\":\"10.1039/D4NJ04283B\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >Based on the chemical structure and luminescence mechanism of luminol, the synthesis of luminol analogues has been widely studied. However, luminol and its derived reagents are still suffering from some drawbacks, such as short luminescence time and weak intensity. Herein, we designed and synthesized a novel hydroxyphenyl benzothiazole-based phthalhydrazide derivative DAH-AMPH, which has a hydroxyphenyl benzothiazole structure as a strong fluorescent site and a cyclic phthalhydrazide structure as a chemiluminescence (CL) emitting site. DAH-AMPH exhibited excellent CL properties in the DAH-AMPH/UHP/hemin CL system for hemin detection with a wide linear range of 0.1 nM to 20.0 nM and low LOD of 3 pM. It exhibited good selectivity in bloodstain imaging on different substrate materials. The DAH-AMPH/UHP/hemin CL system represents a powerful tool for trace detection of bloodstains. Moreover, as a new CL substrate for HRP, DAH-AMPH showed high sensitivity (0.8 pg mL<small><sup>−1</sup></small> of LOD) in the DAH-AMPH/UHP/SPTZ/MORP/HRP CL system indicating bright prospects for the use of DAH-AMPH in heme-containing peroxidase detection.</p>\",\"PeriodicalId\":95,\"journal\":{\"name\":\"New Journal of Chemistry\",\"volume\":\" 17\",\"pages\":\" 7019-7024\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2025-03-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"New Journal of Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://pubs.rsc.org/en/content/articlelanding/2025/nj/d4nj04283b\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"New Journal of Chemistry","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/nj/d4nj04283b","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
A novel luminol-related hydroxyphenyl benzothiazole analogue chemiluminescence probe with ultrahigh sensitivity for bloodstain detection†
Based on the chemical structure and luminescence mechanism of luminol, the synthesis of luminol analogues has been widely studied. However, luminol and its derived reagents are still suffering from some drawbacks, such as short luminescence time and weak intensity. Herein, we designed and synthesized a novel hydroxyphenyl benzothiazole-based phthalhydrazide derivative DAH-AMPH, which has a hydroxyphenyl benzothiazole structure as a strong fluorescent site and a cyclic phthalhydrazide structure as a chemiluminescence (CL) emitting site. DAH-AMPH exhibited excellent CL properties in the DAH-AMPH/UHP/hemin CL system for hemin detection with a wide linear range of 0.1 nM to 20.0 nM and low LOD of 3 pM. It exhibited good selectivity in bloodstain imaging on different substrate materials. The DAH-AMPH/UHP/hemin CL system represents a powerful tool for trace detection of bloodstains. Moreover, as a new CL substrate for HRP, DAH-AMPH showed high sensitivity (0.8 pg mL−1 of LOD) in the DAH-AMPH/UHP/SPTZ/MORP/HRP CL system indicating bright prospects for the use of DAH-AMPH in heme-containing peroxidase detection.