{"title":"同时测量三轴直线运动的增强型外差光栅干涉仪","authors":"Xingyou Chen;Peng Huang;Limin Zhu;Zhiwei Zhu","doi":"10.1109/TIM.2025.3557115","DOIUrl":null,"url":null,"abstract":"A novel heterodyne grating interferometer (HTGI) with a rotationally symmetric optical configuration is proposed to achieve the simultaneous measurement of tri-axial linear motions with a large Z-axis range and a large Z-axis rotation tolerance. In this design, the ±1st-order diffracted beams from one incident beam were purposely rotated around the central axis by an angle of 180° to interfere with them from the other incident beam. In this configuration, all beams can shift identical distances along the same direction to maintain interference, when the grating has large Z-axis motions and rotations. Experimental testing demonstrates high linearities comparable with commercial capacitive sensors, and sub-nanometric resolutions by identifying 0.25 nm motions via the spectrum analysis for all the tri-axial measurements. Moreover, a greatly extended Z-axis range of 7.6 mm and a Z-axis rotation tolerance of 0.75° were achieved, well demonstrating the superiority of the proposed design.","PeriodicalId":13341,"journal":{"name":"IEEE Transactions on Instrumentation and Measurement","volume":"74 ","pages":"1-9"},"PeriodicalIF":5.6000,"publicationDate":"2025-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Enhanced Heterodyne Grating Interferometer for Simultaneously Measuring Tri-Axial Linear Motions\",\"authors\":\"Xingyou Chen;Peng Huang;Limin Zhu;Zhiwei Zhu\",\"doi\":\"10.1109/TIM.2025.3557115\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A novel heterodyne grating interferometer (HTGI) with a rotationally symmetric optical configuration is proposed to achieve the simultaneous measurement of tri-axial linear motions with a large Z-axis range and a large Z-axis rotation tolerance. In this design, the ±1st-order diffracted beams from one incident beam were purposely rotated around the central axis by an angle of 180° to interfere with them from the other incident beam. In this configuration, all beams can shift identical distances along the same direction to maintain interference, when the grating has large Z-axis motions and rotations. Experimental testing demonstrates high linearities comparable with commercial capacitive sensors, and sub-nanometric resolutions by identifying 0.25 nm motions via the spectrum analysis for all the tri-axial measurements. Moreover, a greatly extended Z-axis range of 7.6 mm and a Z-axis rotation tolerance of 0.75° were achieved, well demonstrating the superiority of the proposed design.\",\"PeriodicalId\":13341,\"journal\":{\"name\":\"IEEE Transactions on Instrumentation and Measurement\",\"volume\":\"74 \",\"pages\":\"1-9\"},\"PeriodicalIF\":5.6000,\"publicationDate\":\"2025-04-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Instrumentation and Measurement\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10947537/\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Instrumentation and Measurement","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10947537/","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Enhanced Heterodyne Grating Interferometer for Simultaneously Measuring Tri-Axial Linear Motions
A novel heterodyne grating interferometer (HTGI) with a rotationally symmetric optical configuration is proposed to achieve the simultaneous measurement of tri-axial linear motions with a large Z-axis range and a large Z-axis rotation tolerance. In this design, the ±1st-order diffracted beams from one incident beam were purposely rotated around the central axis by an angle of 180° to interfere with them from the other incident beam. In this configuration, all beams can shift identical distances along the same direction to maintain interference, when the grating has large Z-axis motions and rotations. Experimental testing demonstrates high linearities comparable with commercial capacitive sensors, and sub-nanometric resolutions by identifying 0.25 nm motions via the spectrum analysis for all the tri-axial measurements. Moreover, a greatly extended Z-axis range of 7.6 mm and a Z-axis rotation tolerance of 0.75° were achieved, well demonstrating the superiority of the proposed design.
期刊介绍:
Papers are sought that address innovative solutions to the development and use of electrical and electronic instruments and equipment to measure, monitor and/or record physical phenomena for the purpose of advancing measurement science, methods, functionality and applications. The scope of these papers may encompass: (1) theory, methodology, and practice of measurement; (2) design, development and evaluation of instrumentation and measurement systems and components used in generating, acquiring, conditioning and processing signals; (3) analysis, representation, display, and preservation of the information obtained from a set of measurements; and (4) scientific and technical support to establishment and maintenance of technical standards in the field of Instrumentation and Measurement.