Juan Carlos Huaquisaca Paye, João Paulo A. Vieira, André P. Leão, Jonathan M. Tabora, Ghendy Cardoso Junior
{"title":"架空配电网植被模拟的高阻抗故障模型的实验验证和参数化:来自树枝中压实验室测试的见解","authors":"Juan Carlos Huaquisaca Paye, João Paulo A. Vieira, André P. Leão, Jonathan M. Tabora, Ghendy Cardoso Junior","doi":"10.1049/gtd2.70074","DOIUrl":null,"url":null,"abstract":"<p>The detection and localisation of high impedance faults (HIFs) in overhead distribution networks, particularly those caused by tree contact, remain challenging due to their low fault current magnitude, nonlinear behaviour, and high waveform variability. This study addresses these challenges by experimentally validating and parameterising a two-variable-resistor series model for HIFs. Controlled tests were conducted at the 13.8 kV Extra High Voltage Laboratory (LEAT) of the Federal University of Pará (UFPA), Brazil, using three tree types to collect waveform data. The faults were modelled in ATPDraw software and validated through waveform comparisons, achieving an R<sup>2</sup> coefficient above 0.89, demonstrating excellent agreement between simulated and measured signals. Additionally, comprehensive parameterised data tables detailing resistance variations over time and voltage are provided. These findings not only reduce the need for costly experimental setups in early-stage studies but also provide a solid foundation for developing and testing advanced HIF detection and localisation algorithms, thus contributing to improved power distribution system reliability.</p>","PeriodicalId":13261,"journal":{"name":"Iet Generation Transmission & Distribution","volume":"19 1","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2025-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/gtd2.70074","citationCount":"0","resultStr":"{\"title\":\"Experimental Validation and Parametrisation of a High Impedance Fault Model for Overhead Distribution Networks Vegetation Simulations: Insights From Medium Voltage Laboratory Tests on Tree Branches\",\"authors\":\"Juan Carlos Huaquisaca Paye, João Paulo A. Vieira, André P. Leão, Jonathan M. Tabora, Ghendy Cardoso Junior\",\"doi\":\"10.1049/gtd2.70074\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The detection and localisation of high impedance faults (HIFs) in overhead distribution networks, particularly those caused by tree contact, remain challenging due to their low fault current magnitude, nonlinear behaviour, and high waveform variability. This study addresses these challenges by experimentally validating and parameterising a two-variable-resistor series model for HIFs. Controlled tests were conducted at the 13.8 kV Extra High Voltage Laboratory (LEAT) of the Federal University of Pará (UFPA), Brazil, using three tree types to collect waveform data. The faults were modelled in ATPDraw software and validated through waveform comparisons, achieving an R<sup>2</sup> coefficient above 0.89, demonstrating excellent agreement between simulated and measured signals. Additionally, comprehensive parameterised data tables detailing resistance variations over time and voltage are provided. These findings not only reduce the need for costly experimental setups in early-stage studies but also provide a solid foundation for developing and testing advanced HIF detection and localisation algorithms, thus contributing to improved power distribution system reliability.</p>\",\"PeriodicalId\":13261,\"journal\":{\"name\":\"Iet Generation Transmission & Distribution\",\"volume\":\"19 1\",\"pages\":\"\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2025-04-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1049/gtd2.70074\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iet Generation Transmission & Distribution\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1049/gtd2.70074\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iet Generation Transmission & Distribution","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/gtd2.70074","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Experimental Validation and Parametrisation of a High Impedance Fault Model for Overhead Distribution Networks Vegetation Simulations: Insights From Medium Voltage Laboratory Tests on Tree Branches
The detection and localisation of high impedance faults (HIFs) in overhead distribution networks, particularly those caused by tree contact, remain challenging due to their low fault current magnitude, nonlinear behaviour, and high waveform variability. This study addresses these challenges by experimentally validating and parameterising a two-variable-resistor series model for HIFs. Controlled tests were conducted at the 13.8 kV Extra High Voltage Laboratory (LEAT) of the Federal University of Pará (UFPA), Brazil, using three tree types to collect waveform data. The faults were modelled in ATPDraw software and validated through waveform comparisons, achieving an R2 coefficient above 0.89, demonstrating excellent agreement between simulated and measured signals. Additionally, comprehensive parameterised data tables detailing resistance variations over time and voltage are provided. These findings not only reduce the need for costly experimental setups in early-stage studies but also provide a solid foundation for developing and testing advanced HIF detection and localisation algorithms, thus contributing to improved power distribution system reliability.
期刊介绍:
IET Generation, Transmission & Distribution is intended as a forum for the publication and discussion of current practice and future developments in electric power generation, transmission and distribution. Practical papers in which examples of good present practice can be described and disseminated are particularly sought. Papers of high technical merit relying on mathematical arguments and computation will be considered, but authors are asked to relegate, as far as possible, the details of analysis to an appendix.
The scope of IET Generation, Transmission & Distribution includes the following:
Design of transmission and distribution systems
Operation and control of power generation
Power system management, planning and economics
Power system operation, protection and control
Power system measurement and modelling
Computer applications and computational intelligence in power flexible AC or DC transmission systems
Special Issues. Current Call for papers:
Next Generation of Synchrophasor-based Power System Monitoring, Operation and Control - https://digital-library.theiet.org/files/IET_GTD_CFP_NGSPSMOC.pdf