基于乒乓型菊花型Bi-BiOI和三元核壳结构Pd@AuPt的双电信号输出生物传感器,用于CA19 - 9的精确检测

IF 5.3 2区 化学 Q1 CHEMISTRY, ANALYTICAL
Siyu Wu, Hongyun Ma, Lin Song, Wen Zhong, Yingying Gu, Yuqing Miao, Yarui An
{"title":"基于乒乓型菊花型Bi-BiOI和三元核壳结构Pd@AuPt的双电信号输出生物传感器,用于CA19 - 9的精确检测","authors":"Siyu Wu,&nbsp;Hongyun Ma,&nbsp;Lin Song,&nbsp;Wen Zhong,&nbsp;Yingying Gu,&nbsp;Yuqing Miao,&nbsp;Yarui An","doi":"10.1007/s00604-025-07150-9","DOIUrl":null,"url":null,"abstract":"<div><p>Carbohydrate antigen 19–9 (CA19 - 9) can be used as a biomarker for pancreatic cancer. Measuring the concentration of CA19 - 9 in serum is essential for screening pancreatic cancer patients. In this paper, a dual-electric signal outputs biosensor based on ping pong chrysanthemum-like Bi-BiOI and ternary core–shell structured Pd@AuPt was constructed for ultra-sensitive detection of tumor marker CA19 - 9 using differential pulse voltammetry (DPV) and chronoamperometry (i-t). Ping pong Chrysanthemum-like Bi-BIOI was prepared via one-pot hydrothermal method. To realize the covalent bonding of bismuth-based materials with MWCNT, bismuth-based materials were functionalized by amino groups. MWCNT-NH<sub>2</sub>-Bi-BIOI with large specific surface area and remarkable electrical conductivity was used as the sensing platform. Ternary core–shell structured Pd@AuPt with peroxide-like activity and enhanced biocompatibility immobilized massive antibodies through covalent Au–N and Pt–N bonds, thus broadening the linear range of the immunosensor. Based on the above materials, a dual-electric signal outputs biosensor was constructed for detecting CA19 - 9. Under optimal conditions, the detection range of DPV and i-t is 0.001–150 U/mL, the detection limit of DPV is 0.0003 U/mL, and that of i-t is 0.00024 U/mL. In addition, the dual-electric signal outputs immunoassay excels in anti-interference, splendid reproducibility and high recovery in actual sample detection, indicating that the immunosensor is a promising approach to be applied to the detection of CA19 - 9 in clinical diagnosis.</p><h3>Graphical abstract</h3>\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":705,"journal":{"name":"Microchimica Acta","volume":"192 5","pages":""},"PeriodicalIF":5.3000,"publicationDate":"2025-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ping pong chrysanthemum-like Bi-BiOI and ternary core–shell structured Pd@AuPt based dual-electric signal outputs biosensor for accurate detection of CA19 - 9\",\"authors\":\"Siyu Wu,&nbsp;Hongyun Ma,&nbsp;Lin Song,&nbsp;Wen Zhong,&nbsp;Yingying Gu,&nbsp;Yuqing Miao,&nbsp;Yarui An\",\"doi\":\"10.1007/s00604-025-07150-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Carbohydrate antigen 19–9 (CA19 - 9) can be used as a biomarker for pancreatic cancer. Measuring the concentration of CA19 - 9 in serum is essential for screening pancreatic cancer patients. In this paper, a dual-electric signal outputs biosensor based on ping pong chrysanthemum-like Bi-BiOI and ternary core–shell structured Pd@AuPt was constructed for ultra-sensitive detection of tumor marker CA19 - 9 using differential pulse voltammetry (DPV) and chronoamperometry (i-t). Ping pong Chrysanthemum-like Bi-BIOI was prepared via one-pot hydrothermal method. To realize the covalent bonding of bismuth-based materials with MWCNT, bismuth-based materials were functionalized by amino groups. MWCNT-NH<sub>2</sub>-Bi-BIOI with large specific surface area and remarkable electrical conductivity was used as the sensing platform. Ternary core–shell structured Pd@AuPt with peroxide-like activity and enhanced biocompatibility immobilized massive antibodies through covalent Au–N and Pt–N bonds, thus broadening the linear range of the immunosensor. Based on the above materials, a dual-electric signal outputs biosensor was constructed for detecting CA19 - 9. Under optimal conditions, the detection range of DPV and i-t is 0.001–150 U/mL, the detection limit of DPV is 0.0003 U/mL, and that of i-t is 0.00024 U/mL. In addition, the dual-electric signal outputs immunoassay excels in anti-interference, splendid reproducibility and high recovery in actual sample detection, indicating that the immunosensor is a promising approach to be applied to the detection of CA19 - 9 in clinical diagnosis.</p><h3>Graphical abstract</h3>\\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>\",\"PeriodicalId\":705,\"journal\":{\"name\":\"Microchimica Acta\",\"volume\":\"192 5\",\"pages\":\"\"},\"PeriodicalIF\":5.3000,\"publicationDate\":\"2025-04-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microchimica Acta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s00604-025-07150-9\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microchimica Acta","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s00604-025-07150-9","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

碳水化合物抗原19-9 (CA19 - 9)可作为胰腺癌的生物标志物。测定血清中CA19 - 9的浓度是筛查胰腺癌患者的必要条件。本文构建了一种基于乒乓菊花样Bi-BiOI和三元核壳结构Pd@AuPt的双电信号输出生物传感器,采用差分脉冲伏安法(DPV)和计时电流法(i-t)超灵敏检测肿瘤标志物CA19 - 9。采用一锅水热法制备乒乓样菊花Bi-BIOI。为了实现铋基材料与MWCNT的共价键,铋基材料被氨基功能化。采用比表面积大、导电性好的MWCNT-NH2-Bi-BIOI作为传感平台。三元核壳结构Pd@AuPt具有过氧化物样活性和增强的生物相容性,通过共价Au-N和Pt-N键固定大量抗体,从而扩大了免疫传感器的线性范围。基于上述材料,构建了双电信号输出生物传感器,用于检测CA19 - 9。在最佳条件下,DPV和i-t的检出范围为0.001 ~ 150 U/mL, DPV的检出限为0.0003 U/mL, i-t的检出限为0.00024 U/mL。此外,双电信号输出免疫分析法在实际样品检测中具有抗干扰性好、重现性好、回收率高的特点,表明该免疫传感器在临床诊断中应用于CA19 - 9的检测是一种很有前景的方法。图形抽象
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Ping pong chrysanthemum-like Bi-BiOI and ternary core–shell structured Pd@AuPt based dual-electric signal outputs biosensor for accurate detection of CA19 - 9

Carbohydrate antigen 19–9 (CA19 - 9) can be used as a biomarker for pancreatic cancer. Measuring the concentration of CA19 - 9 in serum is essential for screening pancreatic cancer patients. In this paper, a dual-electric signal outputs biosensor based on ping pong chrysanthemum-like Bi-BiOI and ternary core–shell structured Pd@AuPt was constructed for ultra-sensitive detection of tumor marker CA19 - 9 using differential pulse voltammetry (DPV) and chronoamperometry (i-t). Ping pong Chrysanthemum-like Bi-BIOI was prepared via one-pot hydrothermal method. To realize the covalent bonding of bismuth-based materials with MWCNT, bismuth-based materials were functionalized by amino groups. MWCNT-NH2-Bi-BIOI with large specific surface area and remarkable electrical conductivity was used as the sensing platform. Ternary core–shell structured Pd@AuPt with peroxide-like activity and enhanced biocompatibility immobilized massive antibodies through covalent Au–N and Pt–N bonds, thus broadening the linear range of the immunosensor. Based on the above materials, a dual-electric signal outputs biosensor was constructed for detecting CA19 - 9. Under optimal conditions, the detection range of DPV and i-t is 0.001–150 U/mL, the detection limit of DPV is 0.0003 U/mL, and that of i-t is 0.00024 U/mL. In addition, the dual-electric signal outputs immunoassay excels in anti-interference, splendid reproducibility and high recovery in actual sample detection, indicating that the immunosensor is a promising approach to be applied to the detection of CA19 - 9 in clinical diagnosis.

Graphical abstract

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Microchimica Acta
Microchimica Acta 化学-分析化学
CiteScore
9.80
自引率
5.30%
发文量
410
审稿时长
2.7 months
期刊介绍: As a peer-reviewed journal for analytical sciences and technologies on the micro- and nanoscale, Microchimica Acta has established itself as a premier forum for truly novel approaches in chemical and biochemical analysis. Coverage includes methods and devices that provide expedient solutions to the most contemporary demands in this area. Examples are point-of-care technologies, wearable (bio)sensors, in-vivo-monitoring, micro/nanomotors and materials based on synthetic biology as well as biomedical imaging and targeting.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信