Huahuang Luo;Yuan Wang;Xiaoyi Wang;Yi-Kuen Lee;Qingqing Ke
{"title":"一种基于液体增强微热膨胀的超高灵敏度角运动传感器","authors":"Huahuang Luo;Yuan Wang;Xiaoyi Wang;Yi-Kuen Lee;Qingqing Ke","doi":"10.1109/JSEN.2025.3548725","DOIUrl":null,"url":null,"abstract":"This article presents the development of highly sensitive micro thermal expansion-based angular motion (TEAM) sensors utilizing water and ethanol as the working fluids. Theoretical analysis demonstrates that replacing the gas medium with liquids significantly increases the sensitivity of TEAM sensors, attributed to the larger Rayleigh number (Ra*). Among the two liquids studied, the ethanol-based TEAM sensor exhibits greater sensitivity to fluctuations in thermal properties than the water-based sensor. To ensure waterproofing, a Parylene-C coating was applied as the encapsulation layer for developing the novel liquid-based sensors. Experimental results identify a critical Ra* of 2950, which distinguishes the linear and nonlinear regions of operation for both the water-based and ethanol-based sensors. In the linear region, the water-based and ethanol-based sensors exhibit normalized sensitivities of 0.1638 and 0.37 mV/°/s/mW, respectively, which are more than 10 times and 20 times higher than those of conventional air-based sensors, supporting the theoretical predictions and confirming the feasibility of the proposed design strategy. Furthermore, the ethanol-based TEAM sensor outperforms the sulfur hexafluoride (SF6)-based sensor, currently the most sensitive gas-based thermal angular motion (TAM) sensor, by over five times. The experimental comparisons of single-heater and dual-heater configurations further highlight the importance of the dual-heater setup in minimizing heat loss and enhancing sensor performance, particularly for liquid-based sensors. These findings demonstrate the potential of the liquid-enhanced TEAM sensor for developing more accurate and reliable angular motion detection systems in complex environments.","PeriodicalId":447,"journal":{"name":"IEEE Sensors Journal","volume":"25 8","pages":"12805-12812"},"PeriodicalIF":4.3000,"publicationDate":"2025-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Novel Liquid-Enhanced Micro Thermal Expansion-Based Angular Motion Sensor With Ultrahigh Sensitivity\",\"authors\":\"Huahuang Luo;Yuan Wang;Xiaoyi Wang;Yi-Kuen Lee;Qingqing Ke\",\"doi\":\"10.1109/JSEN.2025.3548725\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This article presents the development of highly sensitive micro thermal expansion-based angular motion (TEAM) sensors utilizing water and ethanol as the working fluids. Theoretical analysis demonstrates that replacing the gas medium with liquids significantly increases the sensitivity of TEAM sensors, attributed to the larger Rayleigh number (Ra*). Among the two liquids studied, the ethanol-based TEAM sensor exhibits greater sensitivity to fluctuations in thermal properties than the water-based sensor. To ensure waterproofing, a Parylene-C coating was applied as the encapsulation layer for developing the novel liquid-based sensors. Experimental results identify a critical Ra* of 2950, which distinguishes the linear and nonlinear regions of operation for both the water-based and ethanol-based sensors. In the linear region, the water-based and ethanol-based sensors exhibit normalized sensitivities of 0.1638 and 0.37 mV/°/s/mW, respectively, which are more than 10 times and 20 times higher than those of conventional air-based sensors, supporting the theoretical predictions and confirming the feasibility of the proposed design strategy. Furthermore, the ethanol-based TEAM sensor outperforms the sulfur hexafluoride (SF6)-based sensor, currently the most sensitive gas-based thermal angular motion (TAM) sensor, by over five times. The experimental comparisons of single-heater and dual-heater configurations further highlight the importance of the dual-heater setup in minimizing heat loss and enhancing sensor performance, particularly for liquid-based sensors. These findings demonstrate the potential of the liquid-enhanced TEAM sensor for developing more accurate and reliable angular motion detection systems in complex environments.\",\"PeriodicalId\":447,\"journal\":{\"name\":\"IEEE Sensors Journal\",\"volume\":\"25 8\",\"pages\":\"12805-12812\"},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2025-03-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Sensors Journal\",\"FirstCategoryId\":\"103\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10925576/\",\"RegionNum\":2,\"RegionCategory\":\"综合性期刊\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Sensors Journal","FirstCategoryId":"103","ListUrlMain":"https://ieeexplore.ieee.org/document/10925576/","RegionNum":2,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
A Novel Liquid-Enhanced Micro Thermal Expansion-Based Angular Motion Sensor With Ultrahigh Sensitivity
This article presents the development of highly sensitive micro thermal expansion-based angular motion (TEAM) sensors utilizing water and ethanol as the working fluids. Theoretical analysis demonstrates that replacing the gas medium with liquids significantly increases the sensitivity of TEAM sensors, attributed to the larger Rayleigh number (Ra*). Among the two liquids studied, the ethanol-based TEAM sensor exhibits greater sensitivity to fluctuations in thermal properties than the water-based sensor. To ensure waterproofing, a Parylene-C coating was applied as the encapsulation layer for developing the novel liquid-based sensors. Experimental results identify a critical Ra* of 2950, which distinguishes the linear and nonlinear regions of operation for both the water-based and ethanol-based sensors. In the linear region, the water-based and ethanol-based sensors exhibit normalized sensitivities of 0.1638 and 0.37 mV/°/s/mW, respectively, which are more than 10 times and 20 times higher than those of conventional air-based sensors, supporting the theoretical predictions and confirming the feasibility of the proposed design strategy. Furthermore, the ethanol-based TEAM sensor outperforms the sulfur hexafluoride (SF6)-based sensor, currently the most sensitive gas-based thermal angular motion (TAM) sensor, by over five times. The experimental comparisons of single-heater and dual-heater configurations further highlight the importance of the dual-heater setup in minimizing heat loss and enhancing sensor performance, particularly for liquid-based sensors. These findings demonstrate the potential of the liquid-enhanced TEAM sensor for developing more accurate and reliable angular motion detection systems in complex environments.
期刊介绍:
The fields of interest of the IEEE Sensors Journal are the theory, design , fabrication, manufacturing and applications of devices for sensing and transducing physical, chemical and biological phenomena, with emphasis on the electronics and physics aspect of sensors and integrated sensors-actuators. IEEE Sensors Journal deals with the following:
-Sensor Phenomenology, Modelling, and Evaluation
-Sensor Materials, Processing, and Fabrication
-Chemical and Gas Sensors
-Microfluidics and Biosensors
-Optical Sensors
-Physical Sensors: Temperature, Mechanical, Magnetic, and others
-Acoustic and Ultrasonic Sensors
-Sensor Packaging
-Sensor Networks
-Sensor Applications
-Sensor Systems: Signals, Processing, and Interfaces
-Actuators and Sensor Power Systems
-Sensor Signal Processing for high precision and stability (amplification, filtering, linearization, modulation/demodulation) and under harsh conditions (EMC, radiation, humidity, temperature); energy consumption/harvesting
-Sensor Data Processing (soft computing with sensor data, e.g., pattern recognition, machine learning, evolutionary computation; sensor data fusion, processing of wave e.g., electromagnetic and acoustic; and non-wave, e.g., chemical, gravity, particle, thermal, radiative and non-radiative sensor data, detection, estimation and classification based on sensor data)
-Sensors in Industrial Practice