{"title":"诱导手性过氧化物酶纳米酶活性的多酚双金属对映体结构,用于胃癌对映体的鉴定","authors":"Qiu-hong Yao ,&nbsp;Mei-huang Zeng ,&nbsp;Chen Zhang ,&nbsp;Feng Zheng ,&nbsp;Jing-wen Jin ,&nbsp;Ting-xiu Ye ,&nbsp;Yi-ting Wang ,&nbsp;Xiao-mei Chen ,&nbsp;Zhi-yong Guo ,&nbsp;Xi Chen","doi":"10.1016/j.bios.2025.117449","DOIUrl":null,"url":null,"abstract":"<div><div><sub>D</sub>-alanine (<sub>D</sub>-Ala) and <sub>D</sub>-proline(<sub>D</sub>-Pro) levels dramatically increase in the bio-fluids of gastric cancer (GC) patients, which are suggested to be potential biomarkers associated with GC. Therefore, monitoring the concentrations of <sub>D</sub>-Pro and <sub>D</sub>-Ala in the body fluids of GC patients is of great significance. In this study, a highly sensitive Surface Enhanced Raman Scattering (SERS) sensor has constructed based on bimetallic heterostructure nanoenzyme (3-MPBA: Co-TA@Ag NPs) for <sub>D</sub>-AAs detection in GC bio-fluids. Attributing to the formation of Ag-Co bimetallic dual active centers, the electron transfer behaviors accelerated boron hydroxyl group ionization in neutral pH, as well as the ultra-robust hydroxyl alcohol esterification reaction occurred between <sub>D</sub>-Ala and <sub>D</sub>-Pro and 3-MPBA. By simply testing different absorbance intensities at various concentrations and sample, a sensor for noninvasive detection of <sub>D</sub>-Pro/Ala is constructed with good specificity and efficiency. Besides, the quantitative determination of <sub>D</sub>-Pro/Ala (limits of detection (LOD) 2.37 μM and 2.15 μM for <sub>D</sub>-Pro/Ala. Furthermore, based on the differential level of <sub>D</sub>-Pro/Ala in GC bio-fluids, the differentiation of saliva samples with <sub>D</sub>-Pro/Ala can also be implemented by the proposed method, showing great potential in GC diagnosis.</div></div>","PeriodicalId":259,"journal":{"name":"Biosensors and Bioelectronics","volume":"282 ","pages":"Article 117449"},"PeriodicalIF":10.7000,"publicationDate":"2025-04-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Polyphenol briged bimetallic-heterostructure inducing chiral peroxidase nanozyme activity for enantiomers identification in gastric cancer\",\"authors\":\"Qiu-hong Yao ,&nbsp;Mei-huang Zeng ,&nbsp;Chen Zhang ,&nbsp;Feng Zheng ,&nbsp;Jing-wen Jin ,&nbsp;Ting-xiu Ye ,&nbsp;Yi-ting Wang ,&nbsp;Xiao-mei Chen ,&nbsp;Zhi-yong Guo ,&nbsp;Xi Chen\",\"doi\":\"10.1016/j.bios.2025.117449\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div><sub>D</sub>-alanine (<sub>D</sub>-Ala) and <sub>D</sub>-proline(<sub>D</sub>-Pro) levels dramatically increase in the bio-fluids of gastric cancer (GC) patients, which are suggested to be potential biomarkers associated with GC. Therefore, monitoring the concentrations of <sub>D</sub>-Pro and <sub>D</sub>-Ala in the body fluids of GC patients is of great significance. In this study, a highly sensitive Surface Enhanced Raman Scattering (SERS) sensor has constructed based on bimetallic heterostructure nanoenzyme (3-MPBA: Co-TA@Ag NPs) for <sub>D</sub>-AAs detection in GC bio-fluids. Attributing to the formation of Ag-Co bimetallic dual active centers, the electron transfer behaviors accelerated boron hydroxyl group ionization in neutral pH, as well as the ultra-robust hydroxyl alcohol esterification reaction occurred between <sub>D</sub>-Ala and <sub>D</sub>-Pro and 3-MPBA. By simply testing different absorbance intensities at various concentrations and sample, a sensor for noninvasive detection of <sub>D</sub>-Pro/Ala is constructed with good specificity and efficiency. Besides, the quantitative determination of <sub>D</sub>-Pro/Ala (limits of detection (LOD) 2.37 μM and 2.15 μM for <sub>D</sub>-Pro/Ala. Furthermore, based on the differential level of <sub>D</sub>-Pro/Ala in GC bio-fluids, the differentiation of saliva samples with <sub>D</sub>-Pro/Ala can also be implemented by the proposed method, showing great potential in GC diagnosis.</div></div>\",\"PeriodicalId\":259,\"journal\":{\"name\":\"Biosensors and Bioelectronics\",\"volume\":\"282 \",\"pages\":\"Article 117449\"},\"PeriodicalIF\":10.7000,\"publicationDate\":\"2025-04-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biosensors and Bioelectronics\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0956566325003239\",\"RegionNum\":1,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors and Bioelectronics","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0956566325003239","RegionNum":1,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

摘要

胃癌(GC)患者生物体液中d -丙氨酸(D-Ala)和d -脯氨酸(D-Pro)水平显著升高,被认为是胃癌的潜在生物标志物。因此,监测GC患者体液中D-Pro和D-Ala的浓度具有重要意义。本研究构建了一种基于双金属异质结构纳米酶(3-MPBA: Co-TA@Ag NPs)的高灵敏度表面增强拉曼散射(SERS)传感器,用于气相色谱生物体液中D-AAs的检测。由于Ag-Co双金属双活性中心的形成,电子转移行为加速了中性pH条件下硼羟基的电离,同时D-Ala与D-Pro和3-MPBA之间发生了超强劲的羟基醇酯化反应。通过简单检测不同浓度和样品的不同吸光度强度,构建了无创检测D-Pro/Ala的传感器,具有良好的特异性和效率。D-Pro/Ala的检测限(LOD)分别为2.37 μM和2.15 μM。此外,基于气相色谱生物液中D-Pro/Ala的差异水平,该方法还可以实现唾液样品与D-Pro/Ala的鉴别,在气相色谱诊断中具有很大的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Polyphenol briged bimetallic-heterostructure inducing chiral peroxidase nanozyme activity for enantiomers identification in gastric cancer
D-alanine (D-Ala) and D-proline(D-Pro) levels dramatically increase in the bio-fluids of gastric cancer (GC) patients, which are suggested to be potential biomarkers associated with GC. Therefore, monitoring the concentrations of D-Pro and D-Ala in the body fluids of GC patients is of great significance. In this study, a highly sensitive Surface Enhanced Raman Scattering (SERS) sensor has constructed based on bimetallic heterostructure nanoenzyme (3-MPBA: Co-TA@Ag NPs) for D-AAs detection in GC bio-fluids. Attributing to the formation of Ag-Co bimetallic dual active centers, the electron transfer behaviors accelerated boron hydroxyl group ionization in neutral pH, as well as the ultra-robust hydroxyl alcohol esterification reaction occurred between D-Ala and D-Pro and 3-MPBA. By simply testing different absorbance intensities at various concentrations and sample, a sensor for noninvasive detection of D-Pro/Ala is constructed with good specificity and efficiency. Besides, the quantitative determination of D-Pro/Ala (limits of detection (LOD) 2.37 μM and 2.15 μM for D-Pro/Ala. Furthermore, based on the differential level of D-Pro/Ala in GC bio-fluids, the differentiation of saliva samples with D-Pro/Ala can also be implemented by the proposed method, showing great potential in GC diagnosis.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biosensors and Bioelectronics
Biosensors and Bioelectronics 工程技术-电化学
CiteScore
20.80
自引率
7.10%
发文量
1006
审稿时长
29 days
期刊介绍: Biosensors & Bioelectronics, along with its open access companion journal Biosensors & Bioelectronics: X, is the leading international publication in the field of biosensors and bioelectronics. It covers research, design, development, and application of biosensors, which are analytical devices incorporating biological materials with physicochemical transducers. These devices, including sensors, DNA chips, electronic noses, and lab-on-a-chip, produce digital signals proportional to specific analytes. Examples include immunosensors and enzyme-based biosensors, applied in various fields such as medicine, environmental monitoring, and food industry. The journal also focuses on molecular and supramolecular structures for enhancing device performance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信