商业健身微环境中高强度体育锻炼期间吸入暴露于室内空气污染物

IF 7.1 1区 工程技术 Q1 CONSTRUCTION & BUILDING TECHNOLOGY
Cátia Peixoto , Maria do Carmo Pereira , Simone Morais , Klara Slezakova
{"title":"商业健身微环境中高强度体育锻炼期间吸入暴露于室内空气污染物","authors":"Cátia Peixoto ,&nbsp;Maria do Carmo Pereira ,&nbsp;Simone Morais ,&nbsp;Klara Slezakova","doi":"10.1016/j.buildenv.2025.112967","DOIUrl":null,"url":null,"abstract":"<div><div>Physical exercise benefits are known, but exposure data across different exercise environments, and activities remain limited. This study estimated indoor air concentrations and inhalation doses of gaseous (total volatile organic compounds – TVOCs, CO<sub>2</sub>) and particulate (PM<sub>10</sub>, PM<sub>2.5</sub>, and ultrafine – 20–1000 nm) pollutants during highly–intense (spinning, dance fitness, and total body workout - TBW) and moderately–intense (body &amp; mind, muscle group-specific and self-defence techniques) in 138 exercise group classes. The USEPA methodology was used to assess inhalation doses across different ages (3 – &lt;61 years old) and genders. CO<sub>2</sub> (mean±SD) ranged from 1368±19 mg/m<sup>3</sup> (in TBW) – 2727±32 mg/m<sup>3</sup> (self-defence-adults), with the protection threshold (2250 mg/m<sup>3</sup>) being exceeded in adult self-defence classes. TVOCs exceeded 4–18 times protective limits (0.6 mg/m<sup>3</sup>) in all classes (mean±SD: 2.49±0.06 mg/m<sup>3</sup> in body &amp; mind – 10.62±0.53 mg/m<sup>3</sup> in self-defence adults). Across different activities, PM widely varied (mean±SD: PM<sub>10</sub>=20.8 ± 0.3 – 220.8 ± 9.7 µg/m<sup>3</sup>; PM<sub>2.5</sub> = 9.1 ± 0.3 – 63.5 ± 1.3 µg/m<sup>3</sup>; UFP=6267±72 – 9917±224 #/cm<sup>3</sup>) with especially PM<sub>10</sub> higher during vigorous human movements; 1.1–4.4 and 1.1–2.5 times exceeding the protective threshold (PM<sub>10</sub>: 50 µg/m<sup>3</sup>; PM<sub>2.5</sub>: 25 µg/m<sup>3</sup>) for PM<sub>10</sub> and PM<sub>2.5</sub>, respectively. High-intensity classes led to 1.1 (16 to &lt;21 yrs) – 1.5 (31 to &lt;41 yrs) times higher total inhalation doses (i.e., Σ<em>D</em>=D<sub>PM10</sub>+D<sub>CO2</sub> +D<sub>TVOCs</sub>) than moderate-intensity classes, and ΣD for men was higher (1–8 % in high- and moderate-intensity, respectively) than for women. Finally, ΣD of child population in self-defence classes were up to 1.99 times higher than those of adults (in self-defence class) of both genders.</div></div>","PeriodicalId":9273,"journal":{"name":"Building and Environment","volume":"278 ","pages":"Article 112967"},"PeriodicalIF":7.1000,"publicationDate":"2025-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Inhalation exposure to indoor air pollutants during moderate- and high-intensity physical exercise in commercial fitness microenvironments\",\"authors\":\"Cátia Peixoto ,&nbsp;Maria do Carmo Pereira ,&nbsp;Simone Morais ,&nbsp;Klara Slezakova\",\"doi\":\"10.1016/j.buildenv.2025.112967\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Physical exercise benefits are known, but exposure data across different exercise environments, and activities remain limited. This study estimated indoor air concentrations and inhalation doses of gaseous (total volatile organic compounds – TVOCs, CO<sub>2</sub>) and particulate (PM<sub>10</sub>, PM<sub>2.5</sub>, and ultrafine – 20–1000 nm) pollutants during highly–intense (spinning, dance fitness, and total body workout - TBW) and moderately–intense (body &amp; mind, muscle group-specific and self-defence techniques) in 138 exercise group classes. The USEPA methodology was used to assess inhalation doses across different ages (3 – &lt;61 years old) and genders. CO<sub>2</sub> (mean±SD) ranged from 1368±19 mg/m<sup>3</sup> (in TBW) – 2727±32 mg/m<sup>3</sup> (self-defence-adults), with the protection threshold (2250 mg/m<sup>3</sup>) being exceeded in adult self-defence classes. TVOCs exceeded 4–18 times protective limits (0.6 mg/m<sup>3</sup>) in all classes (mean±SD: 2.49±0.06 mg/m<sup>3</sup> in body &amp; mind – 10.62±0.53 mg/m<sup>3</sup> in self-defence adults). Across different activities, PM widely varied (mean±SD: PM<sub>10</sub>=20.8 ± 0.3 – 220.8 ± 9.7 µg/m<sup>3</sup>; PM<sub>2.5</sub> = 9.1 ± 0.3 – 63.5 ± 1.3 µg/m<sup>3</sup>; UFP=6267±72 – 9917±224 #/cm<sup>3</sup>) with especially PM<sub>10</sub> higher during vigorous human movements; 1.1–4.4 and 1.1–2.5 times exceeding the protective threshold (PM<sub>10</sub>: 50 µg/m<sup>3</sup>; PM<sub>2.5</sub>: 25 µg/m<sup>3</sup>) for PM<sub>10</sub> and PM<sub>2.5</sub>, respectively. High-intensity classes led to 1.1 (16 to &lt;21 yrs) – 1.5 (31 to &lt;41 yrs) times higher total inhalation doses (i.e., Σ<em>D</em>=D<sub>PM10</sub>+D<sub>CO2</sub> +D<sub>TVOCs</sub>) than moderate-intensity classes, and ΣD for men was higher (1–8 % in high- and moderate-intensity, respectively) than for women. Finally, ΣD of child population in self-defence classes were up to 1.99 times higher than those of adults (in self-defence class) of both genders.</div></div>\",\"PeriodicalId\":9273,\"journal\":{\"name\":\"Building and Environment\",\"volume\":\"278 \",\"pages\":\"Article 112967\"},\"PeriodicalIF\":7.1000,\"publicationDate\":\"2025-04-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Building and Environment\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0360132325004494\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Building and Environment","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0360132325004494","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

体育锻炼的好处是众所周知的,但不同运动环境和活动的暴露数据仍然有限。本研究估算了高强度运动(动感单车、舞蹈健身和全身锻炼)和中等强度运动(身体锻炼)时室内空气中气态(总挥发性有机化合物- TVOCs、CO2)和颗粒物(PM10、PM2.5和超细颗粒物- 20-1000 nm)污染物的浓度和吸入剂量。心理,肌肉群特异性和自卫技术)在138个运动组课程。使用USEPA方法评估不同年龄(3 - 61岁)和性别的吸入剂量。二氧化碳(平均±SD)范围为1368±19 mg/m3 (TBW) - 2727±32 mg/m3(自卫-成人),成人自卫类别超过保护阈值(2250 mg/m3)。所有类别的TVOCs均超过保护限值(0.6 mg/m3)的4-18倍(平均±SD: 2.49±0.06 mg/m3);心理- 10.62±0.53毫克/立方米(自卫成人)。在不同的活动中,PM差异很大(平均±SD: PM10=20.8±0.3 - 220.8±9.7µg/m3;PM2.5 = 9.1±0.3 ~ 63.5±1.3µg/m3;UFP=6267±72 ~ 9917±224 #/cm3),特别是在剧烈运动时PM10更高;超过保护阈值的1.1 ~ 4.4倍和1.1 ~ 2.5倍(PM10: 50µg/m3;PM2.5: PM10和PM2.5分别为25µg/m3。高强度类别导致的总吸入剂量(即ΣD=DPM10+DCO2 +DTVOCs)比中等强度类别高1.1倍(16至21岁)至1.5倍(31至41岁),男性的ΣD比女性高(高强度和中等强度分别为1 - 8%)。最后,自卫班儿童人口ΣD比男女成人(自卫班)高1.99倍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Inhalation exposure to indoor air pollutants during moderate- and high-intensity physical exercise in commercial fitness microenvironments
Physical exercise benefits are known, but exposure data across different exercise environments, and activities remain limited. This study estimated indoor air concentrations and inhalation doses of gaseous (total volatile organic compounds – TVOCs, CO2) and particulate (PM10, PM2.5, and ultrafine – 20–1000 nm) pollutants during highly–intense (spinning, dance fitness, and total body workout - TBW) and moderately–intense (body & mind, muscle group-specific and self-defence techniques) in 138 exercise group classes. The USEPA methodology was used to assess inhalation doses across different ages (3 – <61 years old) and genders. CO2 (mean±SD) ranged from 1368±19 mg/m3 (in TBW) – 2727±32 mg/m3 (self-defence-adults), with the protection threshold (2250 mg/m3) being exceeded in adult self-defence classes. TVOCs exceeded 4–18 times protective limits (0.6 mg/m3) in all classes (mean±SD: 2.49±0.06 mg/m3 in body & mind – 10.62±0.53 mg/m3 in self-defence adults). Across different activities, PM widely varied (mean±SD: PM10=20.8 ± 0.3 – 220.8 ± 9.7 µg/m3; PM2.5 = 9.1 ± 0.3 – 63.5 ± 1.3 µg/m3; UFP=6267±72 – 9917±224 #/cm3) with especially PM10 higher during vigorous human movements; 1.1–4.4 and 1.1–2.5 times exceeding the protective threshold (PM10: 50 µg/m3; PM2.5: 25 µg/m3) for PM10 and PM2.5, respectively. High-intensity classes led to 1.1 (16 to <21 yrs) – 1.5 (31 to <41 yrs) times higher total inhalation doses (i.e., ΣD=DPM10+DCO2 +DTVOCs) than moderate-intensity classes, and ΣD for men was higher (1–8 % in high- and moderate-intensity, respectively) than for women. Finally, ΣD of child population in self-defence classes were up to 1.99 times higher than those of adults (in self-defence class) of both genders.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Building and Environment
Building and Environment 工程技术-工程:环境
CiteScore
12.50
自引率
23.00%
发文量
1130
审稿时长
27 days
期刊介绍: Building and Environment, an international journal, is dedicated to publishing original research papers, comprehensive review articles, editorials, and short communications in the fields of building science, urban physics, and human interaction with the indoor and outdoor built environment. The journal emphasizes innovative technologies and knowledge verified through measurement and analysis. It covers environmental performance across various spatial scales, from cities and communities to buildings and systems, fostering collaborative, multi-disciplinary research with broader significance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信