使用适配体偶联V2CTx MXene的超灵敏电分析传感平台,用于检测HER-2生物标志物

IF 5.8 3区 材料科学 Q1 CHEMISTRY, MULTIDISCIPLINARY
Nanoscale Pub Date : 2025-04-14 DOI:10.1039/d4nr04503c
Reema Rawat, Sonam Singh, Souradeep Roy, Samarika Dubey, Tapas Goswami, Ashish Mathur, James McLaughlin
{"title":"使用适配体偶联V2CTx MXene的超灵敏电分析传感平台,用于检测HER-2生物标志物","authors":"Reema Rawat, Sonam Singh, Souradeep Roy, Samarika Dubey, Tapas Goswami, Ashish Mathur, James McLaughlin","doi":"10.1039/d4nr04503c","DOIUrl":null,"url":null,"abstract":"Breast cancer is a leading cause of mortality among women globally, with the human epidermal growth factor receptor-2 (HER-2) serving as a vital biomarker for its diagnosis and management. In this study, an electrochemical aptasensor was developed using V<small><sub>2</sub></small>CT<small><sub><em>x</em></sub></small> MXene for the sensitive and selective quantification of HER-2. The sensor's electrochemical performance was evaluated through cyclic voltammetry (CV) and square wave voltammetry (SWV) that demonstrated a wide linear detection range of 1 ng mL<small><sup>−1</sup></small> to 100 μg mL<small><sup>−1</sup></small>. The aptasensor achieved an exceptional detection limit of 0.36 ng mL<small><sup>−1</sup></small> and a quantification limit of 1.96 ng mL<small><sup>−1</sup></small> under optimized conditions. Furthermore, the sensor displayed excellent selectivity for HER-2 against other biomarkers and retained stability for 40 days, making it suitable for prolonged use. The high electrochemical response was attributed to the exceptional surface-to-volume ratio and conductivity of the V<small><sub>2</sub></small>CT<small><sub><em>x</em></sub></small> MXene, enabling efficient aptamer immobilization and signal enhancement. These findings highlight the potential of the developed aptasensor as a non-invasive, reliable, and cost-effective platform for early HER-2 detection, paving the way for improved breast cancer diagnosis and monitoring.","PeriodicalId":92,"journal":{"name":"Nanoscale","volume":"6 1","pages":""},"PeriodicalIF":5.8000,"publicationDate":"2025-04-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ultrasensitive electroanalytical sensing platform using aptamer-conjugated V2CTx MXene for the detection of the HER-2 biomarker\",\"authors\":\"Reema Rawat, Sonam Singh, Souradeep Roy, Samarika Dubey, Tapas Goswami, Ashish Mathur, James McLaughlin\",\"doi\":\"10.1039/d4nr04503c\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Breast cancer is a leading cause of mortality among women globally, with the human epidermal growth factor receptor-2 (HER-2) serving as a vital biomarker for its diagnosis and management. In this study, an electrochemical aptasensor was developed using V<small><sub>2</sub></small>CT<small><sub><em>x</em></sub></small> MXene for the sensitive and selective quantification of HER-2. The sensor's electrochemical performance was evaluated through cyclic voltammetry (CV) and square wave voltammetry (SWV) that demonstrated a wide linear detection range of 1 ng mL<small><sup>−1</sup></small> to 100 μg mL<small><sup>−1</sup></small>. The aptasensor achieved an exceptional detection limit of 0.36 ng mL<small><sup>−1</sup></small> and a quantification limit of 1.96 ng mL<small><sup>−1</sup></small> under optimized conditions. Furthermore, the sensor displayed excellent selectivity for HER-2 against other biomarkers and retained stability for 40 days, making it suitable for prolonged use. The high electrochemical response was attributed to the exceptional surface-to-volume ratio and conductivity of the V<small><sub>2</sub></small>CT<small><sub><em>x</em></sub></small> MXene, enabling efficient aptamer immobilization and signal enhancement. These findings highlight the potential of the developed aptasensor as a non-invasive, reliable, and cost-effective platform for early HER-2 detection, paving the way for improved breast cancer diagnosis and monitoring.\",\"PeriodicalId\":92,\"journal\":{\"name\":\"Nanoscale\",\"volume\":\"6 1\",\"pages\":\"\"},\"PeriodicalIF\":5.8000,\"publicationDate\":\"2025-04-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nanoscale\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.1039/d4nr04503c\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nanoscale","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1039/d4nr04503c","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

乳腺癌是全球女性死亡的主要原因,人类表皮生长因子受体-2 (HER-2)是其诊断和治疗的重要生物标志物。在本研究中,利用V2CTx MXene开发了一种电化学感应传感器,用于HER-2的敏感和选择性定量。通过循环伏安法(CV)和方波伏安法(SWV)对传感器的电化学性能进行了评价,结果表明传感器的线性检测范围为1 ng mL−1 ~ 100 μg mL−1。在优化条件下,该传感器的检测限为0.36 ng mL - 1,定量限为1.96 ng mL - 1。此外,该传感器对HER-2对其他生物标志物表现出优异的选择性,并保持40天的稳定性,使其适合长期使用。高电化学响应归因于V2CTx MXene优异的表面体积比和电导率,从而实现了有效的适配体固定和信号增强。这些发现突出了开发的适配体传感器作为早期HER-2检测的无创、可靠和经济的平台的潜力,为改善乳腺癌的诊断和监测铺平了道路。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Ultrasensitive electroanalytical sensing platform using aptamer-conjugated V2CTx MXene for the detection of the HER-2 biomarker

Ultrasensitive electroanalytical sensing platform using aptamer-conjugated V2CTx MXene for the detection of the HER-2 biomarker
Breast cancer is a leading cause of mortality among women globally, with the human epidermal growth factor receptor-2 (HER-2) serving as a vital biomarker for its diagnosis and management. In this study, an electrochemical aptasensor was developed using V2CTx MXene for the sensitive and selective quantification of HER-2. The sensor's electrochemical performance was evaluated through cyclic voltammetry (CV) and square wave voltammetry (SWV) that demonstrated a wide linear detection range of 1 ng mL−1 to 100 μg mL−1. The aptasensor achieved an exceptional detection limit of 0.36 ng mL−1 and a quantification limit of 1.96 ng mL−1 under optimized conditions. Furthermore, the sensor displayed excellent selectivity for HER-2 against other biomarkers and retained stability for 40 days, making it suitable for prolonged use. The high electrochemical response was attributed to the exceptional surface-to-volume ratio and conductivity of the V2CTx MXene, enabling efficient aptamer immobilization and signal enhancement. These findings highlight the potential of the developed aptasensor as a non-invasive, reliable, and cost-effective platform for early HER-2 detection, paving the way for improved breast cancer diagnosis and monitoring.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Nanoscale
Nanoscale CHEMISTRY, MULTIDISCIPLINARY-NANOSCIENCE & NANOTECHNOLOGY
CiteScore
12.10
自引率
3.00%
发文量
1628
审稿时长
1.6 months
期刊介绍: Nanoscale is a high-impact international journal, publishing high-quality research across nanoscience and nanotechnology. Nanoscale publishes a full mix of research articles on experimental and theoretical work, including reviews, communications, and full papers.Highly interdisciplinary, this journal appeals to scientists, researchers and professionals interested in nanoscience and nanotechnology, quantum materials and quantum technology, including the areas of physics, chemistry, biology, medicine, materials, energy/environment, information technology, detection science, healthcare and drug discovery, and electronics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信