概述:基于 MOFs 或 COFs 的二氧化碳 QCM 气体传感器的设计策略

Xukun Wang, Tong Zhang
{"title":"概述:基于 MOFs 或 COFs 的二氧化碳 QCM 气体传感器的设计策略","authors":"Xukun Wang,&nbsp;Tong Zhang","doi":"10.1002/adsr.202400170","DOIUrl":null,"url":null,"abstract":"<p>The quartz crystal microbalance (QCM) platform is a high-performance sensor device in which the change in the characteristic quantity of the sensor does not depend on the difference in the electrical amount of the sensitive material but is related only to the adsorption capacity of the exposed material. Metal–organic frameworks (MOFs)/covalent–organic frameworks (COFs), as a functional material, have unique physical and chemical properties and are capable of trapping and adsorbing gases in large quantities. QCM gas sensors based on MOFs or COFs have a promising application in CO<sub>2</sub> gas sensing. This work summarizes the current research on CO<sub>2</sub> sensors and the current problems and challenges. Different improvement strategies are concluded for gas sensors' core “4S” characteristics, that is, sensitivity, selectivity, response speed, and stability. To provide some ideas and suggestions for the future development of MOFs/COFs-based QCM carbon dioxide gas sensors.</p>","PeriodicalId":100037,"journal":{"name":"Advanced Sensor Research","volume":"4 4","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-03-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/adsr.202400170","citationCount":"0","resultStr":"{\"title\":\"An Overview: A Design Strategy for Dioxide Carbon QCM Gas Sensor Based on MOFs or COFs\",\"authors\":\"Xukun Wang,&nbsp;Tong Zhang\",\"doi\":\"10.1002/adsr.202400170\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The quartz crystal microbalance (QCM) platform is a high-performance sensor device in which the change in the characteristic quantity of the sensor does not depend on the difference in the electrical amount of the sensitive material but is related only to the adsorption capacity of the exposed material. Metal–organic frameworks (MOFs)/covalent–organic frameworks (COFs), as a functional material, have unique physical and chemical properties and are capable of trapping and adsorbing gases in large quantities. QCM gas sensors based on MOFs or COFs have a promising application in CO<sub>2</sub> gas sensing. This work summarizes the current research on CO<sub>2</sub> sensors and the current problems and challenges. Different improvement strategies are concluded for gas sensors' core “4S” characteristics, that is, sensitivity, selectivity, response speed, and stability. To provide some ideas and suggestions for the future development of MOFs/COFs-based QCM carbon dioxide gas sensors.</p>\",\"PeriodicalId\":100037,\"journal\":{\"name\":\"Advanced Sensor Research\",\"volume\":\"4 4\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-03-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/adsr.202400170\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advanced Sensor Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/adsr.202400170\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Sensor Research","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/adsr.202400170","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。

An Overview: A Design Strategy for Dioxide Carbon QCM Gas Sensor Based on MOFs or COFs

An Overview: A Design Strategy for Dioxide Carbon QCM Gas Sensor Based on MOFs or COFs

The quartz crystal microbalance (QCM) platform is a high-performance sensor device in which the change in the characteristic quantity of the sensor does not depend on the difference in the electrical amount of the sensitive material but is related only to the adsorption capacity of the exposed material. Metal–organic frameworks (MOFs)/covalent–organic frameworks (COFs), as a functional material, have unique physical and chemical properties and are capable of trapping and adsorbing gases in large quantities. QCM gas sensors based on MOFs or COFs have a promising application in CO2 gas sensing. This work summarizes the current research on CO2 sensors and the current problems and challenges. Different improvement strategies are concluded for gas sensors' core “4S” characteristics, that is, sensitivity, selectivity, response speed, and stability. To provide some ideas and suggestions for the future development of MOFs/COFs-based QCM carbon dioxide gas sensors.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信