Lujia Yang, Chaohui Lv, Zhongwei Yang, Feng Shi, Xiayan Liu
{"title":"基于拉曼光谱的血清内脂素特征峰筛选冠心病研究。","authors":"Lujia Yang, Chaohui Lv, Zhongwei Yang, Feng Shi, Xiayan Liu","doi":"10.1097/MD.0000000000042081","DOIUrl":null,"url":null,"abstract":"<p><p>This study used Raman spectroscopy to explore differences between serum visfatin and its subcomponents in healthy people and coronary heart disease (CHD) patients. To explore whether serum visfatin can be used as screening biomarker for CDH. In total, 60 CHD patients and 57 healthy people were enrolled from Xinjiang Production and Construction Corps Seventh Division Hospital. Serum samples were collected and detected by Raman spectroscopy, and the characteristic peaks of serum visfatin were analyzed. The spectral peaks analysis showed, the peaks at 850.95, 1265.92, 1336.99, 1446.48, 1603.83, and 1657.69 cm-1 were stronger in the CHD patient sample, and the spectral peaks at 1000.52, 1154.51, and 1515.53 cm-1 were stronger in the healthy sample. Clinical sample verification revealed that the 1265.92 and 1446.48 cm-1 peaks had certain distinguishing effects on CHD patients and healthy people.</p>","PeriodicalId":18549,"journal":{"name":"Medicine","volume":"104 14","pages":"e42081"},"PeriodicalIF":1.3000,"publicationDate":"2025-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Serum visfatin characteristic peak screening coronary heart disease study based on Raman spectroscopy.\",\"authors\":\"Lujia Yang, Chaohui Lv, Zhongwei Yang, Feng Shi, Xiayan Liu\",\"doi\":\"10.1097/MD.0000000000042081\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study used Raman spectroscopy to explore differences between serum visfatin and its subcomponents in healthy people and coronary heart disease (CHD) patients. To explore whether serum visfatin can be used as screening biomarker for CDH. In total, 60 CHD patients and 57 healthy people were enrolled from Xinjiang Production and Construction Corps Seventh Division Hospital. Serum samples were collected and detected by Raman spectroscopy, and the characteristic peaks of serum visfatin were analyzed. The spectral peaks analysis showed, the peaks at 850.95, 1265.92, 1336.99, 1446.48, 1603.83, and 1657.69 cm-1 were stronger in the CHD patient sample, and the spectral peaks at 1000.52, 1154.51, and 1515.53 cm-1 were stronger in the healthy sample. Clinical sample verification revealed that the 1265.92 and 1446.48 cm-1 peaks had certain distinguishing effects on CHD patients and healthy people.</p>\",\"PeriodicalId\":18549,\"journal\":{\"name\":\"Medicine\",\"volume\":\"104 14\",\"pages\":\"e42081\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2025-04-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/MD.0000000000042081\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MD.0000000000042081","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
Serum visfatin characteristic peak screening coronary heart disease study based on Raman spectroscopy.
This study used Raman spectroscopy to explore differences between serum visfatin and its subcomponents in healthy people and coronary heart disease (CHD) patients. To explore whether serum visfatin can be used as screening biomarker for CDH. In total, 60 CHD patients and 57 healthy people were enrolled from Xinjiang Production and Construction Corps Seventh Division Hospital. Serum samples were collected and detected by Raman spectroscopy, and the characteristic peaks of serum visfatin were analyzed. The spectral peaks analysis showed, the peaks at 850.95, 1265.92, 1336.99, 1446.48, 1603.83, and 1657.69 cm-1 were stronger in the CHD patient sample, and the spectral peaks at 1000.52, 1154.51, and 1515.53 cm-1 were stronger in the healthy sample. Clinical sample verification revealed that the 1265.92 and 1446.48 cm-1 peaks had certain distinguishing effects on CHD patients and healthy people.
期刊介绍:
Medicine is now a fully open access journal, providing authors with a distinctive new service offering continuous publication of original research across a broad spectrum of medical scientific disciplines and sub-specialties.
As an open access title, Medicine will continue to provide authors with an established, trusted platform for the publication of their work. To ensure the ongoing quality of Medicine’s content, the peer-review process will only accept content that is scientifically, technically and ethically sound, and in compliance with standard reporting guidelines.