{"title":"在胫骨高位截骨术中检测骨转换的器械锤:一项动物研究。","authors":"Manon Bas, Teddy Ketani, Claire Bastard, Giuseppe Rosi, Hugues Albini, Charles-Henri Flouzat Lachaniette, Arnaud Dubory, Guillaume Haïat","doi":"10.1115/1.4068372","DOIUrl":null,"url":null,"abstract":"<p><p>High Tibial Osteotomy is a common procedure for knee osteoarthritis during which the surgeon opens the tibia and must stop impacting when cortical bone is reached by the osteotome. Surgeons rely on proprioception and fluoroscopy to conduct the surgery. Our group has developed an instrumented hammer to assess the mechanical properties of the material surrounding the osteotome tip. The aim of this study is to determine whether this hammer can be used to detect the transition from cortical to trabecular bone. Osteotomies were performed until rupture in pig tibia using the instrumented hammer. An algorithm was developed to detect both transitions based on the relative variation of an indicator derived from the time variation of the force. The detection by the algorithm of both transitions was compared with the position of the osteotome measured with a video camera and with surgeon proprioception. The difference between the detection of the video and the algorithm (respectively the video and the surgeon; the surgeon and the algorithm) is 1.0 ± 1.5 impacts (respectively 0.5 ± 0.6 impacts; 1.4 ± 1.8 impacts), for the detection of the transition from the cortical to trabecular bone. For the transition from the trabecular to cortical bone, the difference is 3.6 ± 2.6 impacts (respectively 3.9±2.4 impacts; 0.8 ± 0.9 impacts) and the detection by the algorithm was always done before the sample rupture. This ex vivo study demonstrates that this method could prevent impacts leading to hinge rupture.</p>","PeriodicalId":54871,"journal":{"name":"Journal of Biomechanical Engineering-Transactions of the Asme","volume":" ","pages":"1-33"},"PeriodicalIF":1.7000,"publicationDate":"2025-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An instrumented hammer to detect the bone transitions during an high tibial osteotomy: an animal study.\",\"authors\":\"Manon Bas, Teddy Ketani, Claire Bastard, Giuseppe Rosi, Hugues Albini, Charles-Henri Flouzat Lachaniette, Arnaud Dubory, Guillaume Haïat\",\"doi\":\"10.1115/1.4068372\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>High Tibial Osteotomy is a common procedure for knee osteoarthritis during which the surgeon opens the tibia and must stop impacting when cortical bone is reached by the osteotome. Surgeons rely on proprioception and fluoroscopy to conduct the surgery. Our group has developed an instrumented hammer to assess the mechanical properties of the material surrounding the osteotome tip. The aim of this study is to determine whether this hammer can be used to detect the transition from cortical to trabecular bone. Osteotomies were performed until rupture in pig tibia using the instrumented hammer. An algorithm was developed to detect both transitions based on the relative variation of an indicator derived from the time variation of the force. The detection by the algorithm of both transitions was compared with the position of the osteotome measured with a video camera and with surgeon proprioception. The difference between the detection of the video and the algorithm (respectively the video and the surgeon; the surgeon and the algorithm) is 1.0 ± 1.5 impacts (respectively 0.5 ± 0.6 impacts; 1.4 ± 1.8 impacts), for the detection of the transition from the cortical to trabecular bone. For the transition from the trabecular to cortical bone, the difference is 3.6 ± 2.6 impacts (respectively 3.9±2.4 impacts; 0.8 ± 0.9 impacts) and the detection by the algorithm was always done before the sample rupture. This ex vivo study demonstrates that this method could prevent impacts leading to hinge rupture.</p>\",\"PeriodicalId\":54871,\"journal\":{\"name\":\"Journal of Biomechanical Engineering-Transactions of the Asme\",\"volume\":\" \",\"pages\":\"1-33\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2025-04-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Biomechanical Engineering-Transactions of the Asme\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4068372\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomechanical Engineering-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4068372","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

摘要

胫骨高位截骨术是治疗膝关节骨性关节炎的一种常用方法,在此过程中,外科医生打开胫骨,当截骨术到达皮质骨时必须停止冲击。外科医生依靠本体感觉和透视来进行手术。我们的小组已经开发了一种仪器锤来评估骨切开术尖端周围材料的机械性能。本研究的目的是确定这种锤是否可以用来检测从皮质骨到小梁骨的过渡。使用带器械的榔头对猪胫骨进行截骨术直至骨折。开发了一种算法,根据力的时间变化得出的指标的相对变化来检测这两种转变。将这两种转换算法的检测结果与用摄像机测量的截骨位置和外科医生的本体感觉进行比较。视频和算法检测的区别(分别是视频和外科医生;术者和算法)分别为1.0±1.5个冲击(分别为0.5±0.6个冲击;1.4±1.8次撞击),用于检测从皮质骨到小梁骨的过渡。从小梁骨向皮质骨过渡时,差异为3.6±2.6次冲击(分别为3.9±2.4次冲击;0.8±0.9冲击),且算法总是在试样破裂前进行检测。该离体研究表明,该方法可以防止导致铰链断裂的冲击。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An instrumented hammer to detect the bone transitions during an high tibial osteotomy: an animal study.

High Tibial Osteotomy is a common procedure for knee osteoarthritis during which the surgeon opens the tibia and must stop impacting when cortical bone is reached by the osteotome. Surgeons rely on proprioception and fluoroscopy to conduct the surgery. Our group has developed an instrumented hammer to assess the mechanical properties of the material surrounding the osteotome tip. The aim of this study is to determine whether this hammer can be used to detect the transition from cortical to trabecular bone. Osteotomies were performed until rupture in pig tibia using the instrumented hammer. An algorithm was developed to detect both transitions based on the relative variation of an indicator derived from the time variation of the force. The detection by the algorithm of both transitions was compared with the position of the osteotome measured with a video camera and with surgeon proprioception. The difference between the detection of the video and the algorithm (respectively the video and the surgeon; the surgeon and the algorithm) is 1.0 ± 1.5 impacts (respectively 0.5 ± 0.6 impacts; 1.4 ± 1.8 impacts), for the detection of the transition from the cortical to trabecular bone. For the transition from the trabecular to cortical bone, the difference is 3.6 ± 2.6 impacts (respectively 3.9±2.4 impacts; 0.8 ± 0.9 impacts) and the detection by the algorithm was always done before the sample rupture. This ex vivo study demonstrates that this method could prevent impacts leading to hinge rupture.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.40
自引率
5.90%
发文量
169
审稿时长
4-8 weeks
期刊介绍: Artificial Organs and Prostheses; Bioinstrumentation and Measurements; Bioheat Transfer; Biomaterials; Biomechanics; Bioprocess Engineering; Cellular Mechanics; Design and Control of Biological Systems; Physiological Systems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信