污水站和住宅泵站的PFAS前体升高

IF 8.9 2区 环境科学与生态学 Q1 ENGINEERING, ENVIRONMENTAL
Michael Penrose, Jacob Deighton, Susan T. Glassmeyer, Andrew Brougham, Scott M. Bessler*, Taryn Mcknight and Mohamed Ateia*, 
{"title":"污水站和住宅泵站的PFAS前体升高","authors":"Michael Penrose,&nbsp;Jacob Deighton,&nbsp;Susan T. Glassmeyer,&nbsp;Andrew Brougham,&nbsp;Scott M. Bessler*,&nbsp;Taryn Mcknight and Mohamed Ateia*,&nbsp;","doi":"10.1021/acs.estlett.5c0024610.1021/acs.estlett.5c00246","DOIUrl":null,"url":null,"abstract":"<p >Residential wastewater, with no industrial inputs, is an underrecognized source of per- and polyfluoroalkyl substances (PFAS). This study provides the first direct comparison of PFAS in septage and pump stations, targeting 70 PFAS compounds and employing the total oxidizable precursor (TOP) assay. Septage exhibited markedly higher PFAS and precursors concentrations than pump stations, with median post-TOP levels of 687.5 ng/L vs 84.2 ng/L, respectively. FTCAs were fully oxidized, while diPAPs showed incomplete oxidation due to high organic loads. Septic systems function as PFAS reservoirs, increasing risks of groundwater contamination, particularly in areas with shallow aquifers. Pump stations contributed to episodic PFAS spikes, likely affecting downstream wastewater treatment. The detection of 27 PFAS compounds, including short-chain alternatives, highlights shifting contamination patterns. Findings emphasize the need for tailored analytical frameworks and pretreatment technologies to mitigate PFAS risks across decentralized and centralized wastewater systems. Integrating precursor analysis is critical for accurate risk assessment, as targeted PFAS measurements underestimate contamination. These results provide new insights into PFAS behavior in residential wastewater, guiding future mitigation efforts.</p>","PeriodicalId":37,"journal":{"name":"Environmental Science & Technology Letters Environ.","volume":"12 4","pages":"454–460 454–460"},"PeriodicalIF":8.9000,"publicationDate":"2025-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Elevated PFAS Precursors in Septage and Residential Pump Stations\",\"authors\":\"Michael Penrose,&nbsp;Jacob Deighton,&nbsp;Susan T. Glassmeyer,&nbsp;Andrew Brougham,&nbsp;Scott M. Bessler*,&nbsp;Taryn Mcknight and Mohamed Ateia*,&nbsp;\",\"doi\":\"10.1021/acs.estlett.5c0024610.1021/acs.estlett.5c00246\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >Residential wastewater, with no industrial inputs, is an underrecognized source of per- and polyfluoroalkyl substances (PFAS). This study provides the first direct comparison of PFAS in septage and pump stations, targeting 70 PFAS compounds and employing the total oxidizable precursor (TOP) assay. Septage exhibited markedly higher PFAS and precursors concentrations than pump stations, with median post-TOP levels of 687.5 ng/L vs 84.2 ng/L, respectively. FTCAs were fully oxidized, while diPAPs showed incomplete oxidation due to high organic loads. Septic systems function as PFAS reservoirs, increasing risks of groundwater contamination, particularly in areas with shallow aquifers. Pump stations contributed to episodic PFAS spikes, likely affecting downstream wastewater treatment. The detection of 27 PFAS compounds, including short-chain alternatives, highlights shifting contamination patterns. Findings emphasize the need for tailored analytical frameworks and pretreatment technologies to mitigate PFAS risks across decentralized and centralized wastewater systems. Integrating precursor analysis is critical for accurate risk assessment, as targeted PFAS measurements underestimate contamination. These results provide new insights into PFAS behavior in residential wastewater, guiding future mitigation efforts.</p>\",\"PeriodicalId\":37,\"journal\":{\"name\":\"Environmental Science & Technology Letters Environ.\",\"volume\":\"12 4\",\"pages\":\"454–460 454–460\"},\"PeriodicalIF\":8.9000,\"publicationDate\":\"2025-03-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Environmental Science & Technology Letters Environ.\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://pubs.acs.org/doi/10.1021/acs.estlett.5c00246\",\"RegionNum\":2,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ENVIRONMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental Science & Technology Letters Environ.","FirstCategoryId":"1","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acs.estlett.5c00246","RegionNum":2,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

没有工业投入的生活废水是全氟烷基和多氟烷基物质(PFAS)的一个未得到充分认识的来源。这项研究首次对污水处理厂和泵站的PFAS进行了直接比较,针对70种PFAS化合物,并采用了总氧化前体(TOP)测定法。Septage的PFAS和前体浓度明显高于泵站,top后的中位浓度分别为687.5 ng/L和84.2 ng/L。ftca被完全氧化,而dip则由于高有机负荷而表现为不完全氧化。化粪池系统作为PFAS水库,增加了地下水污染的风险,特别是在浅层含水层地区。泵站造成了间歇性PFAS峰值,可能影响下游废水处理。27种PFAS化合物的检测,包括短链替代品,突出了污染模式的变化。研究结果强调需要量身定制的分析框架和预处理技术,以减轻分散和集中废水系统中的PFAS风险。整合前体分析对于准确的风险评估至关重要,因为有针对性的PFAS测量低估了污染。这些结果为PFAS在生活废水中的行为提供了新的见解,指导了未来的减排工作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Elevated PFAS Precursors in Septage and Residential Pump Stations

Elevated PFAS Precursors in Septage and Residential Pump Stations

Residential wastewater, with no industrial inputs, is an underrecognized source of per- and polyfluoroalkyl substances (PFAS). This study provides the first direct comparison of PFAS in septage and pump stations, targeting 70 PFAS compounds and employing the total oxidizable precursor (TOP) assay. Septage exhibited markedly higher PFAS and precursors concentrations than pump stations, with median post-TOP levels of 687.5 ng/L vs 84.2 ng/L, respectively. FTCAs were fully oxidized, while diPAPs showed incomplete oxidation due to high organic loads. Septic systems function as PFAS reservoirs, increasing risks of groundwater contamination, particularly in areas with shallow aquifers. Pump stations contributed to episodic PFAS spikes, likely affecting downstream wastewater treatment. The detection of 27 PFAS compounds, including short-chain alternatives, highlights shifting contamination patterns. Findings emphasize the need for tailored analytical frameworks and pretreatment technologies to mitigate PFAS risks across decentralized and centralized wastewater systems. Integrating precursor analysis is critical for accurate risk assessment, as targeted PFAS measurements underestimate contamination. These results provide new insights into PFAS behavior in residential wastewater, guiding future mitigation efforts.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Environmental Science & Technology Letters Environ.
Environmental Science & Technology Letters Environ. ENGINEERING, ENVIRONMENTALENVIRONMENTAL SC-ENVIRONMENTAL SCIENCES
CiteScore
17.90
自引率
3.70%
发文量
163
期刊介绍: Environmental Science & Technology Letters serves as an international forum for brief communications on experimental or theoretical results of exceptional timeliness in all aspects of environmental science, both pure and applied. Published as soon as accepted, these communications are summarized in monthly issues. Additionally, the journal features short reviews on emerging topics in environmental science and technology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信