采用多普勒超声门控相衬磁共振成像测量胎儿心输出量的可行性随着胎龄的增加而增加。

IF 4.2 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
Signe Gade Hellmuth, Ditte Staub Jørgensen, Kasper Gadsbøll, Caroline Taksøe-Vester, Ann Tabor, Olav Bjørn Petersen, Niels Vejlstrup
{"title":"采用多普勒超声门控相衬磁共振成像测量胎儿心输出量的可行性随着胎龄的增加而增加。","authors":"Signe Gade Hellmuth, Ditte Staub Jørgensen, Kasper Gadsbøll, Caroline Taksøe-Vester, Ann Tabor, Olav Bjørn Petersen, Niels Vejlstrup","doi":"10.1016/j.jocmr.2025.101892","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Fetal magnetic resonance imaging (MRI) is a valuable tool for assessing fetal blood flow; however, its use has primarily been focused on near-term pregnancies. This study aimed to evaluate the feasibility of Doppler ultrasound-gated 2D phase-contrast cardiac MRI of the human fetus in the early, mid, and late third trimester.</p><p><strong>Methods: </strong>A total of 100 fetal MRI scans were performed at gestational age (GA) 28, 32 and 38 weeks in 38 fetuses with (n=13) and without (n=25) congenital heart defects. Combined ventricular output was measured by Doppler ultrasound gated 2D phase contrast MRI in the ascending aorta and main pulmonary artery. Success rate of acquisition, repeatability of phase contrast-measurements and intra-/interobserver agreement were assessed at each GA.</p><p><strong>Results: </strong>Combined ventricular output was obtained in 76/100 (76%) scans. The success rate of acquisition improved with increasing GA from 15/34 (44%) at GA 28 weeks to 31/35 (89%) at GA 32 weeks (p <0.001 compared to 28 weeks) and 30/31 (97%) at GA 38 weeks (p <0.001 compared to 28 weeks). Repeatability of phase contrast measurements demonstrated a moderate to strong correlation (r = 0.63 - 0.82, p = 0.002), with no significant bias but wide limits of agreement. The mean difference ±95% limits of agreement were 7.3±245mL/min, -13.0±260mL/min, and -3.9±326mL/min at 28, 32, and 38 weeks, respectively.</p><p><strong>Conclusion: </strong>Feasibility of fetal cardiac MRI improves with increasing GA. While Doppler-gated 2D phase contrast MRI can effectively assess fetal combined ventricular output and allows for in-group comparisons, the precision may still be insufficient for clinical application.</p>","PeriodicalId":15221,"journal":{"name":"Journal of Cardiovascular Magnetic Resonance","volume":" ","pages":"101892"},"PeriodicalIF":4.2000,"publicationDate":"2025-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Feasibility of fetal cardiac output measurement by phase contrast magnetic resonance imaging using Doppler ultrasound gating increases with gestational age.\",\"authors\":\"Signe Gade Hellmuth, Ditte Staub Jørgensen, Kasper Gadsbøll, Caroline Taksøe-Vester, Ann Tabor, Olav Bjørn Petersen, Niels Vejlstrup\",\"doi\":\"10.1016/j.jocmr.2025.101892\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Fetal magnetic resonance imaging (MRI) is a valuable tool for assessing fetal blood flow; however, its use has primarily been focused on near-term pregnancies. This study aimed to evaluate the feasibility of Doppler ultrasound-gated 2D phase-contrast cardiac MRI of the human fetus in the early, mid, and late third trimester.</p><p><strong>Methods: </strong>A total of 100 fetal MRI scans were performed at gestational age (GA) 28, 32 and 38 weeks in 38 fetuses with (n=13) and without (n=25) congenital heart defects. Combined ventricular output was measured by Doppler ultrasound gated 2D phase contrast MRI in the ascending aorta and main pulmonary artery. Success rate of acquisition, repeatability of phase contrast-measurements and intra-/interobserver agreement were assessed at each GA.</p><p><strong>Results: </strong>Combined ventricular output was obtained in 76/100 (76%) scans. The success rate of acquisition improved with increasing GA from 15/34 (44%) at GA 28 weeks to 31/35 (89%) at GA 32 weeks (p <0.001 compared to 28 weeks) and 30/31 (97%) at GA 38 weeks (p <0.001 compared to 28 weeks). Repeatability of phase contrast measurements demonstrated a moderate to strong correlation (r = 0.63 - 0.82, p = 0.002), with no significant bias but wide limits of agreement. The mean difference ±95% limits of agreement were 7.3±245mL/min, -13.0±260mL/min, and -3.9±326mL/min at 28, 32, and 38 weeks, respectively.</p><p><strong>Conclusion: </strong>Feasibility of fetal cardiac MRI improves with increasing GA. While Doppler-gated 2D phase contrast MRI can effectively assess fetal combined ventricular output and allows for in-group comparisons, the precision may still be insufficient for clinical application.</p>\",\"PeriodicalId\":15221,\"journal\":{\"name\":\"Journal of Cardiovascular Magnetic Resonance\",\"volume\":\" \",\"pages\":\"101892\"},\"PeriodicalIF\":4.2000,\"publicationDate\":\"2025-04-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Cardiovascular Magnetic Resonance\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.jocmr.2025.101892\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Magnetic Resonance","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jocmr.2025.101892","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:胎儿磁共振成像(MRI)是评估胎儿血流的一种有价值的工具;然而,它的使用主要集中在近期怀孕。本研究旨在评估多普勒超声门控二维相位对比心脏MRI在妊娠早期、中期和晚期的可行性。方法:对38例有先天性心脏缺陷(n=13)和无先天性心脏缺陷(n=25)的胎儿在胎龄(GA) 28、32和38周时进行100次胎儿MRI扫描。采用多普勒超声门控二维相对比MRI检测升主动脉和肺动脉联合心室输出量。在每次GA上评估采集成功率、相位对比测量的可重复性和观察者之间的一致性。结果:合并心室输出在76/100(76%)的扫描中获得。随着GA的增加,获得成功率从GA 28周时的15/34(44%)提高到GA 32周时的31/35(89%)。虽然多普勒门控二维相对比MRI可以有效地评估胎儿联合心室输出量并允许组内比较,但其精度可能仍不足以用于临床应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Feasibility of fetal cardiac output measurement by phase contrast magnetic resonance imaging using Doppler ultrasound gating increases with gestational age.

Background: Fetal magnetic resonance imaging (MRI) is a valuable tool for assessing fetal blood flow; however, its use has primarily been focused on near-term pregnancies. This study aimed to evaluate the feasibility of Doppler ultrasound-gated 2D phase-contrast cardiac MRI of the human fetus in the early, mid, and late third trimester.

Methods: A total of 100 fetal MRI scans were performed at gestational age (GA) 28, 32 and 38 weeks in 38 fetuses with (n=13) and without (n=25) congenital heart defects. Combined ventricular output was measured by Doppler ultrasound gated 2D phase contrast MRI in the ascending aorta and main pulmonary artery. Success rate of acquisition, repeatability of phase contrast-measurements and intra-/interobserver agreement were assessed at each GA.

Results: Combined ventricular output was obtained in 76/100 (76%) scans. The success rate of acquisition improved with increasing GA from 15/34 (44%) at GA 28 weeks to 31/35 (89%) at GA 32 weeks (p <0.001 compared to 28 weeks) and 30/31 (97%) at GA 38 weeks (p <0.001 compared to 28 weeks). Repeatability of phase contrast measurements demonstrated a moderate to strong correlation (r = 0.63 - 0.82, p = 0.002), with no significant bias but wide limits of agreement. The mean difference ±95% limits of agreement were 7.3±245mL/min, -13.0±260mL/min, and -3.9±326mL/min at 28, 32, and 38 weeks, respectively.

Conclusion: Feasibility of fetal cardiac MRI improves with increasing GA. While Doppler-gated 2D phase contrast MRI can effectively assess fetal combined ventricular output and allows for in-group comparisons, the precision may still be insufficient for clinical application.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
10.90
自引率
12.50%
发文量
61
审稿时长
6-12 weeks
期刊介绍: Journal of Cardiovascular Magnetic Resonance (JCMR) publishes high-quality articles on all aspects of basic, translational and clinical research on the design, development, manufacture, and evaluation of cardiovascular magnetic resonance (CMR) methods applied to the cardiovascular system. Topical areas include, but are not limited to: New applications of magnetic resonance to improve the diagnostic strategies, risk stratification, characterization and management of diseases affecting the cardiovascular system. New methods to enhance or accelerate image acquisition and data analysis. Results of multicenter, or larger single-center studies that provide insight into the utility of CMR. Basic biological perceptions derived by CMR methods.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信